This paper deals with the negative effects produced by unexpected energy of solar array and methods of suppressing the effects for the sequential switching shunt regulator (S3R). The complex space operation conditions such as plasma environment and accidental impact are likely to cause abnormal discharge of solar array, leading to unexpected changes in the input energy of an S3R. Effects of unexpected energy on current stress and power loss of power devices, over-regulation of the S3R and quality of output voltage are represented and analyzed in this paper. A shunt regulator topology based on the switch current limiting drive (SCLSR) is then proposed to suppress current stress and power loss of power devices, thereby alleviating negative effects. Finally, simulation and experimental results are provided to illustrate the negative effects of unexpected energy and validate the proposed shunt regulator.
With the aim to solve the problem of the non-linear phenomenon of the satellite power system under the influence of the space environment factors, which threatens the stability of the power system, in this paper, the abnormal charging and discharging of solar arrays and solar array drive assembly (SADA) induced by the space plasma environment and accidental events, such as debris impact, and the non-linear behaviors of the solar array and load during the Earth eclipse are modeled and analyzed. On this basis, the hazard risk evaluations of the above non-linear phenomena are carried out, and the weak links of the satellite power system in the space environment are identified. The results show that the unexpected energy of the solar array will increase the current stress and power loss of the power device, resulting in S3R over-regulation. An SADA arc fault will reduce the power supply capacity of the solar array, damage the shunt regulator, and affect the quality of the bus. The non-linear behavior of the solar array and load during the Earth eclipse may damage the battery charge and discharge regulator, seriously affecting the stability of the power system.
The solar array drive assembly (SADA) slip ring is a critical link that provides electrical power and electric signal transmission between solar arrays and satellite power systems, which is prone to arc faults in the space environment. If these arc faults cannot be detected and eliminated quickly enough, they will seriously threaten the safety of the satellite power system and the satellite. In this paper, a fast arc detection method based on fractal dimension is proposed that adapts to different operating modes of power systems. The detection method collects the current differential signal data flowing through the SADA slip ring, and, according to the trend of the fractal dimension change in this signal, the fault identification algorithm is designed for different operating modes of the power system to achieve real-time and rapid identification of arc faults. Finally, the effectiveness of the proposed method is demonstrated using test data under several different fault conditions.