Hassan Adnan Kenjrawy

Dr. Hassan Adnan Kenjrawy

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2022 in Electronics
Verified
Journal Article
Open access
PDF file
HKHassan Adnan Kenjrawy
Hassan Adnan Kenjrawy
Carlo Youssef MakdisiCarlo Youssef Makdisi
Carlo Youssef Makdisi
IHIssam Houssamo
Issam Houssamo
Nabil MohammedNabil Mohammed
Nabil Mohammed
The use of sensitive electronic devices has increased recently; hence, power quality has become an important factor in electrical power systems. The various disturbances occurring in the electrical network (harmonics, voltage swells, sags, etc.) may lead to technical-economic damage that negatively impacts the quality of the supplied power. Therefore, the use of the Unified Power Quality Conditioner (UPQC) is a promising solution to limit such damage. In this paper, a nine-level structure of the proposed standardized power quality conditioner is analyzed. The conditioner is connected between a photovoltaic system (UPQC-PV) and a smart grid. Then, a new approach to generate switches for the switches of both the series and parallel converters is proposed. This modulation technique relies on an adaptive hysteresis band (AHB) that is determined via a fuzzy logic controller in order to obtain the required modified output voltage with minimum distortion. Simulation results, using MATLAB/Simulink, of different disturbance scenarios that may occur in the network are presented to verify the accuracy of the proposed fuzzy-logic-based AHB control system. Compared with the conventional SPWM, it is found that the proposed AHB modulation technique significantly improves the power quality in terms of producing less total harmonic distortion in both the voltage and current waveforms.

1 January 2025 in International Journal of Energy Research
Verified
Journal Article
Open access
LHLedan Huang
Ledan Huang
AMAli M. Mohsen
Ali M. Mohsen
HKHassan Adnan Kenjrawy
Hassan Adnan Kenjrawy
MAMohammed H. Almaamori
Mohammed H. Almaamori
JZJingyu Zhang
Jingyu Zhang
HRHesam Rahbarimagham
Hesam Rahbarimagham
One of the major problems of the operators of electricity networks is the operation of the network during events. Events with high impact and low probability of occurrence are a type of events that can cause severe disruptions in power grids. Therefore, the power grid must be resilient in dealing with such events. In recent years, electricity network operators have tried to improve the conditions of using distribution networks by using methods called flexibility. This paper aims to use flexible methods, such as energy storage systems and demand response programs to increase resiliency, reduce costs, and level the power exchange curve with the sub‐distribution substation. Therefore, first, the modeling of energy storage systems and demand response programs is presented in the energy management problem. Then, the mentioned models are integrated with the problem of the resilient operation of the two‐way distribution network. Also, considering the parameters of active and reactive loads and active generation of wind and solar renewable energy resources, uncertainty is considered in the problem. The resilient operation model has been considered and rewritten again, considering the robust optimization method for modeling uncertainties. Finally, a resiliency index is provided to show the resiliency of a network in a relative manner. In the proposed model, the simulation is done on IEEE 33‐bus network in four states and six cases. The states considered include grid operation without energy storage systems and demand response programs, operation with energy storage systems, operation with demand response programs, and operation with the simultaneous presence of energy storage systems and demand response programs. Also, in this paper, six cases include operation in normal conditions for comparison with other cases, operation in outage conditions of one‐way and two‐way busses connected to the sub‐distribution substation, operations in disconnection of some local resources, and network lines have been investigated. The results obtained from this research indicate the improvement of resiliency conditions using the method considered.