The application range of existing real scale mobile thermal storage units with phase change materials (PCM) is restricted by the low phase change temperature of 58 for sodium acetate trihydrate, which is a commonly used storage material. Therefore, only low temperature heat sinks like swimming pools or greenhouses can be supplied. With increasing phase change temperatures, more applications like domestic heating or industrial process heat could be operated. The aim of this study is to find alternative PCM with phase change temperatures between 90 and 150 . Temperature dependent thermophysical properties like phase change temperatures and enthalpies, densities and thermal diffusivities are measured for the technical grade purity materials xylitol (C H O ), erythritol (C H O ) and magnesiumchloride hexahydrate (MCHH, MgCl 6H O). The sugar alcohols xylitol and erythritol indicate a large supercooling and different melting regimes. The salt hydrate MgCl 6H O seems to be a suitable candidate for practical applications. It has a melting temperature of 115.1 ± 0.1 and a phase change enthalpy of 166.9 ± 1.2 with only 2.8 supercooling at sample sizes of 100 . The PCM is stable over 500 repeated melting and solidification cycles at differential scanning calorimeter (DSC) scale with only small changes of the melting enthalpy and temperature.
1 February 2018 in International Journal of Heat and Mass Transfer
In this work we derive temperature-dependent functions for the most important material properties needed for phase change studies with octadecane. Over 80 references are reviewed in which at least one thermophysical property of octadecane is measured. The functions are valid ±40 K around the melting temperature and are surrounded by their confidence interval. It turns out that the values for the solid phase have much broader confidence intervals than the ones of the liquid phase. Hence, more accurate measurements are particularly desirable for the solid state material properties.
The design of phase-change material (PCM)-based thermal energy storage (TES) systems is challenging since a lot of PCMs have low thermal conductivities and a considerable volume change during phase-change. The low thermal conductivity restricts energy transport due to the increasing thermal resistance of the progressing phase boundary and hence large heat transfer areas or temperature differences are required to achieve sufficient storage power. An additional volume has to be considered in the storage system to compensate for volume change. Macro-encapsulation of the PCM is one method to overcome these drawbacks. When designed as stiff containers with an air cushion, the macro-capsules compensate for volume change of the PCM which facilitates the design of PCM storage systems. The capsule walls provide a large surface for heat transfer and the thermal resistance is reduced due to the limited thickness of the capsules. Although the principles and advantages of macro-encapsulation have been well known for many years, no detailed analysis of the whole encapsulation process has been published yet. Therefore, this research proposes a detailed development strategy for the whole encapsulation process. Various possibilities for corrosion protection, fill and seal strategies and capsule geometries are studied. The proposed workflow is applied for the encapsulation of the salt hydrate magnesiumchloride hexahydrate (MCHH, MgCl H O) within metal capsules but can also be assigned to other material combinations.
1 June 2019 in International Journal of Heat and Mass Transfer
An important prerequisite to select a reliable phase change material (PCM) for thermal energy storage applications is to test it under application conditions. In the case of solid–liquid PCM, a large amount of thermal energy can be stored and released in a small temperature range around the solid–liquid phase transition. Therefore, to test the long-term stability of solid–liquid PCM, they are subjected to melting and solidification processes taking into account the conditions of the intended application. In this work, 18 experimental devices to investigate the long-term stability of PCM are presented. The experiments can be divided into thermal cycling stability tests, tests on PCM with stable supercooling, and tests on the stability of phase change slurries (PCS). In addition to these experiments, appropriate methods to investigate a possible degradation of the PCM are introduced. Considering the diversity of the investigated devices and the wide range of experimental parameters, further work toward a standardization of PCM stability testing is recommended.