Andreas König-Haagen

Dr. Andreas König-Haagen


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2017 in Materials
Verified
Journal Article
Open access
PDF file
SHStephan Höhlein
Stephan Höhlein
AKAndreas König-Haagen
Andreas König-Haagen
DBDieter Brüggemann
Dieter Brüggemann
The application range of existing real scale mobile thermal storage units with phase change materials (PCM) is restricted by the low phase change temperature of 58 ∘ C for sodium acetate trihydrate, which is a commonly used storage material. Therefore, only low temperature heat sinks like swimming pools or greenhouses can be supplied. With increasing phase change temperatures, more applications like domestic heating or industrial process heat could be operated. The aim of this study is to find alternative PCM with phase change temperatures between 90 and 150 ∘ C . Temperature dependent thermophysical properties like phase change temperatures and enthalpies, densities and thermal diffusivities are measured for the technical grade purity materials xylitol (C 5 H 12 O 5 ), erythritol (C 4 H 10 O 4 ) and magnesiumchloride hexahydrate (MCHH, MgCl 2 · 6H 2 O). The sugar alcohols xylitol and erythritol indicate a large supercooling and different melting regimes. The salt hydrate MgCl 2 · 6H 2 O seems to be a suitable candidate for practical applications. It has a melting temperature of 115.1 ± 0.1 ∘ C and a phase change enthalpy of 166.9 ± 1.2 J / g with only 2.8 K supercooling at sample sizes of 100 g . The PCM is stable over 500 repeated melting and solidification cycles at differential scanning calorimeter (DSC) scale with only small changes of the melting enthalpy and temperature.

14 September 2019 in Materials
Verified
Journal Article
Open access
PDF file
MFMoritz Faden
Moritz Faden
SHStephan Höhlein
Stephan Höhlein
JWJoschka Wanner
Joschka Wanner
AKAndreas König-Haagen
Andreas König-Haagen
DBDieter Brüggemann
Dieter Brüggemann
In this work we derive temperature-dependent functions for the most important material properties needed for phase change studies with octadecane. Over 80 references are reviewed in which at least one thermophysical property of octadecane is measured. The functions are valid ±40 K around the melting temperature and are surrounded by their confidence interval. It turns out that the values for the solid phase have much broader confidence intervals than the ones of the liquid phase. Hence, more accurate measurements are particularly desirable for the solid state material properties.

17 September 2018 in Materials
Verified
Journal Article
Open access
PDF file
SHStephan Höhlein
Stephan Höhlein
AKAndreas König-Haagen
Andreas König-Haagen
DBDieter Brüggemann
Dieter Brüggemann
The design of phase-change material (PCM)-based thermal energy storage (TES) systems is challenging since a lot of PCMs have low thermal conductivities and a considerable volume change during phase-change. The low thermal conductivity restricts energy transport due to the increasing thermal resistance of the progressing phase boundary and hence large heat transfer areas or temperature differences are required to achieve sufficient storage power. An additional volume has to be considered in the storage system to compensate for volume change. Macro-encapsulation of the PCM is one method to overcome these drawbacks. When designed as stiff containers with an air cushion, the macro-capsules compensate for volume change of the PCM which facilitates the design of PCM storage systems. The capsule walls provide a large surface for heat transfer and the thermal resistance is reduced due to the limited thickness of the capsules. Although the principles and advantages of macro-encapsulation have been well known for many years, no detailed analysis of the whole encapsulation process has been published yet. Therefore, this research proposes a detailed development strategy for the whole encapsulation process. Various possibilities for corrosion protection, fill and seal strategies and capsule geometries are studied. The proposed workflow is applied for the encapsulation of the salt hydrate magnesiumchloride hexahydrate (MCHH, MgCl 2 · 6 H 2 O) within metal capsules but can also be assigned to other material combinations.

5 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
MFMoritz Faden
Moritz Faden
AKAndreas König-Haagen
Andreas König-Haagen
DBDieter Brüggemann
Dieter Brüggemann
Classical numerical methods for solving solid–liquid phase change assume a constant density upon melting or solidification and are not efficient when applied to phase change with volume expansion or shrinkage. However, solid–liquid phase change is accompanied by a volume change and an appropriate numerical method must take this into account. Therefore, an efficient algorithm for solid–liquid phase change with a density change is presented. Its performance for a one-dimensional solidification problem and for the quasi two-dimensional melting of octadecane in a cubic cavity was tested. The new algorithm requires less than 1/9 of the iterations compared to the source based method in one dimension and less than 1/7 in two dimensions. Moreover, the new method is validated against PIV measurements from the literature. A conjugate heat transfer simulation, which includes parts of the experimental setup, shows that parasitic heat fluxes can significantly alter the shape of the phase front near the bottom wall.

25 February 2017 in Energies
Verified
Journal Article
Open access
PDF file
SKSebastian Kuboth
Sebastian Kuboth
AKAndreas König-Haagen
Andreas König-Haagen
DBDieter Brüggemann
Dieter Brüggemann
Latent thermal energy storage (LTS) systems are versatile due to their high-energy storage density within a small temperature range. In shell-and-tube type storage systems fins can be used in order to achieve enhanced charging and discharging power. Typically, circular fins are evenly distributed over the length of the heat exchanger pipe. However, it is yet to be proven that this allocation is the most suitable for every kind of system and application. Consequently, within this paper, a simulation model was developed in order to examine the effect of different fin distributions on the performance of shell-and-tube type latent thermal storage units at discharge. The model was set up in MATLAB Simulink R2015b (The MathWorks, Inc., Natick, MA, USA) based on the enthalpy method and validated by a reference model designed in ANSYS Fluent 15.0 (ANSYS, Inc., Canonsburg, PA, USA). The fin density of the heat exchanger pipe was increased towards the pipe outlet. This concentration of fins was implemented linearly, exponentially or suddenly with the total number of fins remaining constant during the variation of fin allocations. Results show that there is an influence of fin allocation on storage performance. However, the average storage performance at total discharge only increased by three percent with the best allocation compared to an equidistant arrangement.

10 November 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CRChristoph Rathgeber
Christoph Rathgeber
SHStefan Hiebler
Stefan Hiebler
Rocío BayónRocío Bayón
Rocío Bayón
Luisa F. CabezaLuisa F. Cabeza
Luisa F. Cabeza
Gabriel ZsembinszkiGabriel Zsembinszki
Gabriel Zsembinszki
Laurent ZALEWSKILaurent ZALEWSKI
Laurent ZALEWSKI
An important prerequisite to select a reliable phase change material (PCM) for thermal energy storage applications is to test it under application conditions. In the case of solid–liquid PCM, a large amount of thermal energy can be stored and released in a small temperature range around the solid–liquid phase transition. Therefore, to test the long-term stability of solid–liquid PCM, they are subjected to melting and solidification processes taking into account the conditions of the intended application. In this work, 18 experimental devices to investigate the long-term stability of PCM are presented. The experiments can be divided into thermal cycling stability tests, tests on PCM with stable supercooling, and tests on the stability of phase change slurries (PCS). In addition to these experiments, appropriate methods to investigate a possible degradation of the PCM are introduced. Considering the diversity of the investigated devices and the wide range of experimental parameters, further work toward a standardization of PCM stability testing is recommended.