Rongan Zhai

Dr. Rongan Zhai

Shanghai University, Shanghai, China
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
RZRongan Zhai
Rongan Zhai
GSGuanqiao Shan
Guanqiao Shan
CDChangsheng Dai
Changsheng Dai
MHMiao Hao
Miao Hao
JZJunhui Zhu
Junhui Zhu
YSYu Sun
Yu Sun
Denudation is a technique for removal of the cumulus cell mass from oocytes in clinical intracytoplasmic sperm injection (ICSI). Manual oocyte denudation requires long training hours and stringent skills, but still suffers from low yield rate and denudation efficiency due to human fatigue and skill variations across operators. To address these limitations, this paper reports a robotic system for automated oocyte denudation. In this system, several key techniques are proposed, including a vision-based contact detection method for measuring the relative z position between the micropipette tip and the dish substrate, recognition of oocytes and the surrounding cumulus cells, automated calibration algorithm for eliminating the misalignment angle, and automated control of the flow rate based on the model of oocyte dynamics during micropipette aspiration and deposition. Experiments on mouse oocytes demonstrated that the robotic denudation system achieved a high yield rate of 97.0 ± 2.8% and denudation efficiency of 95.0 ± 0.8%. Additionally, oocytes denuded by the robotic system showed comparable fertilization rate and developmental competence compared with manual denudation. Our robotic denudation system represents one step towards the automation and standardization of ICSI procedures.

21 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MHMiao Hao
Miao Hao
RZRongan Zhai
Rongan Zhai
YWYong Wang
Yong Wang
CRChanghai Ru
Changhai Ru
BYBin Yang
Bin Yang
Sperm morphology assessment plays a vital role in semen analysis and the diagnosis of male infertility. By quantitatively analyzing the morphological characteristics of the sperm head, midpiece, and tail, it provides essential insights for assisted reproductive technologies (ARTs), such as in vitro fertilization (IVF). However, traditional manual evaluation methods not only rely on staining procedures that can damage the cells but also suffer from strong subjectivity and inconsistent results, underscoring the urgent need for an automated, accurate, and non-invasive method for multi-sperm morphology assessment. To address the limitations of existing techniques, this study proposes a novel method that combines a multi-scale part parsing network with a measurement accuracy enhancement strategy for non-stained sperm morphology analysis. First, a multi-scale part parsing network integrating semantic segmentation and instance segmentation is introduced to achieve instance-level parsing of sperm, enabling precise measurement of morphological parameters for each individual sperm instance. Second, to eliminate measurement errors caused by the reduced resolution of non-stained sperm images, a measurement accuracy enhancement method based on statistical analysis and signal processing is designed. This method employs an interquartile range (IQR) method to exclude outliers, Gaussian filtering to smooth data, and robust correction techniques to extract the maximum morphological features of sperm. Experimental results demonstrate that the proposed multi-scale part parsing network achieves 59.3% APvolp, surpassing the state-of-the-art AIParsing by 9.20%. Compared to evaluations based solely on segmentation results, the integration of the measurement accuracy enhancement strategy significantly reduces measurement errors, with the largest reduction in errors for head, midpiece, and tail measurements reaching up to 35.0%.

11 August 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
JZJunhui Zhu
Junhui Zhu
PPPENG PAN
PENG PAN
YWYong Wang
Yong Wang
SGSEN GU
SEN GU
RZRongan Zhai
Rongan Zhai
CRChanghai Ru
Changhai Ru
The piezoelectrically-actuated stick-slip nanopositioning stage (PASSNS) has been applied extensively, and many designs of PASSNSs have been developed. The friction force between the stick-slip surfaces plays a critical role in successful movement of the stage, which influences the load capacity, dynamic performance, and positioning accuracy of the PASSNS. Toward solving the influence problems of friction force, this paper presents a novel stick-slip nanopositioning stage where the flexure hinge-based friction force adjusting unit was employed. Numerical analysis was conducted to estimate the static performance of the stage, a dynamic model was established, and simulation analysis was performed to study the dynamic performance of the stage. Further, a prototype was manufactured and a series of experiments were carried out to test the performance of the stage. The results show that the maximum forward and backward movement speeds of the stage are 1 and 0.7 mm/s, respectively, and the minimum forward and backward step displacements are approximately 11 and 12 nm, respectively. Compared to the step displacement under no working load, the forward and backward step displacements only increase by 6% and 8% with a working load of 20 g, respectively. And the load capacity of the PASSNS in the vertical direction is about 72 g. The experimental results confirm the feasibility of the proposed stage, and high accuracy, high speed, and good robustness to varying loads were achieved. These results demonstrate the great potential of the developed stage in many nanopositioning applications.

5 April 2024 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
AJAojun Jiang
Aojun Jiang
MHMiao Hao
Miao Hao
YLYiqian Li
Yiqian Li
JWJiaqi Wang
Jiaqi Wang
CYChunfeng Yue
Chunfeng Yue
ZZZhuoran Zhang
Zhuoran Zhang
This paper presents an automated point-of-care semen analysis method that uses smartphone imaging to visually measure sperm concentration and motility of semen samples. The proposed method follows the same visual tracking scheme as laboratory semen analysis systems, aiming to match clinical standards while being suitable for point-of-care use. A boundary-sensitive segmentation network is developed to identify and distinguish sperm from impurities in raw semen. A novel occlusion-aware multi-sperm tracking algorithm is proposed to tackle challenges posed by smartphone imaging and undiluted raw semen samples. For automated motility measurement, an occlusion-awareness module is proposed to robustly track multiple sperm during frequent sperm crossover/occlusion. The module combines the segmented contour and kinematic-based probabilistic modeling to determine the occlusion status of both targets and measurements, facilitating fundamental improvement to feasible joint event enumeration to enable robust data association. The proposed method achieved a high success rate of 95.14% for tracking occluded sperm, with low mean errors for sperm concentration (2.03 million/ml) and motility (1.58%), outperforming existing multi-sperm tracking methods. In clinical tests involving 50 participants, our method exhibited good agreement with clinical standards (Spearman rank correlation coefficients of 0.94 for concentration and 0.89 for motility) even when used by inexperienced users. Note to Practitioners —Semen analysis is the gold standard method for assessing male reproductive capacity. Clinical semen analysis routinely uses professional computer-assisted semen analysis (CASA) systems to examine sperm concentration and motility; however, clinical visits for semen analysis are not always feasible due to the unavailability of such professional systems and the mental stress brought by clinical visits. This work provides a point-of-care semen analysis method. For hardware, a smartphone microscopic imaging modality was developed to enable clear visualization of sperm with the built-in smartphone camera. For software, an occlusion-aware multi-sperm tracking algorithm was proposed to automatically measure sperm concentration and motility. In addition to intensively validating the proposed point-of-care method against clinical CASA systems, this work also analyzed different types of tracking failure and quantified their effects on the automated evaluation of sperm concentration and motility. The techniques pave the way for further improvement in both point-of-care and clinical semen analysis. Overall, this work offers an accessible and reliable tool for automated male fertility evaluation.

30 March 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
MHMiao Hao
Miao Hao
BYBin Yang
Bin Yang
CRChanghai Ru
Changhai Ru
CYChunfeng Yue
Chunfeng Yue
ZHZongjie Huang
Zongjie Huang
CDChangsheng Dai
Changsheng Dai
In order to improve the positioning accuracy of the micromanipulation system, a comprehensive error model is first established to take into account the microscope nonlinear imaging distortion, camera installation error, and the mechanical displacement error of the motorized stage. A novel error compensation method is then proposed with distortion compensation coefficients obtained by the Levenberg–Marquardt optimization algorithm combined with the deduced nonlinear imaging model. The compensation coefficients for camera installation error and mechanical displacement error are derived from the rigid-body translation technique and image stitching algorithm. To validate the error compensation model, single shot and cumulative error tests were designed. The experimental results show that after the error compensation, the displacement errors were controlled within 0.25 μm when moving in a single direction and within 0.02 μm per 1000 μm when moving in multiple directions.

19 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RZRongan Zhai
Rongan Zhai
MHMiao Hao
Miao Hao
YWYong Wang
Yong Wang
CRChanghai Ru
Changhai Ru
JZJunhui Zhu
Junhui Zhu
The removal of cumulus cells from cumulus–oocyte complexes is a critical step in clinical in vitro fertilization. Since the oocyte is partially occluded by the surrounding cumulus cells and individual cumulus cells are small in size, it is difficult for embryologists to assess the oocyte's maturity before cumulus cell removal and to completely remove all the cumulus cells manually . Furthermore, it is easy for the oocyte to become lost inside the micropipette during aspiration due to the inaccuracy of manual control. To deal with these difficulties, a robotic system was developed to completely remove cumulus cells from mature oocytes. In this study, an EPSANet50 network was developed to accurately assess the maturity of oocytes, avoiding the removal of cumulus cells around the immature oocyte. An adaptive controller was designed to accurately position oocytes at the target position, reducing the loss of oocytes inside the micropipette. An improved Yolov5s network was proposed to quantify the number and size of cumulus cells and assess the completeness of cumulus cell removal. The experimental results on mouse cumulus–oocyte complexes showed that the robotic system had a higher success rate (98.0 ± 1.8% vs. 85.3 ± 2.4%) and lower discard rate (4.1 ± 2.7% vs. 19.6 ± 3.5%) than the manual operation. Moreover, a higher amplification rate and lower non-specific rate were also achieved by the robotic system in the subsequent genetic testing procedure, indicating reduced genetic contamination from the cumulus cells.