Combining fiber with concrete mixes has become essential and its widespread use improves the strength of structural concrete elements. This research conducted an experiment into the structural performance of flat slabs with and without a square opening using four types of fiber (hooked-end, straight, corrugated steel fiber and polyolefin fiber) to gain a better understanding of how the variance of fiber type and shape effects the flexural behaviors of two-way slabs. The test program involved (a) testing the properties of hardened concrete, such as compressive properties, modulus of rupture and splitting tensile strength, and (b) testing the flexural behavior of two-way slabs. Ten slabs were divided into five pairs, including two specimens used as reference specimens (with and without openings), and eight other specimens with different types of fibers. Results revealed that the existing fiber in concrete improved the mechanical properties of hardened concrete mix, and the compressive strength test showed higher improvement in specimens with hooked and straight steel fiber. The flexural behavior of reinforced concrete slab was significantly enhanced, and the flexural strength capacity was especially improved for the slabs strengthened with hooked-end and corrugated steel fiber. Polyolefin fiber showed a slight enhancement of mechanical properties and good improvement in flexural capacity. Generally, the highest increments in compressive strength and modulus of rupture were 24.8%, 20% and 11%, and the ultimate load-carrying capacity of slabs was 39%, 13% and 19% for specimens with steel hooked, steel corrugated and polyolefin fibers, respectively, compared with control specimens.
A study of the behavior of fibers in high-strength reinforced concrete beams is presented in this paper. Twelve reinforced concrete beams were tested under a pure torsion load. Different compressive strengths (45.2, 64.7, and 84.8 MPa) and fiber volume fractions (0, 0.25, 0.5, and 0.75) with variable spacing between transverse reinforcements have been used. It was discovered that the maximum torque of a high-strength concrete beam is increased by about 20.3, 25.6, and 27.1% when the fractional volume of fiber is increased from 0 to 0.25, 0.5 and 0.75 respectively (when the compressive strength is 45.2 MPa and the transverse reinforcement spacing is 100 mm). The test results show that the ultimate torsional strength becomes higher when the concrete compressive strength increases, and this percentage increase becomes higher with increasing steel fiber volume fraction. When the spacing between transverse reinforcements decreases from 150 to 100 mm, the ultimate torque increases by 19.9%. When the spacing between transverse reinforcements decreases from 100 to 60 mm, the ultimate torque increases by 17.0%. In these beams, the fibers' compressive strength and volume fraction were kept constant at 45.2 MPa and 0.75, respectively.
This paper presents the influence of polyolefin fiber on the flexural and shear attitude on the flat slabs. Three slab sets (80 cm × 80 cm) were tested, each with a thickness of 10 cm. In the first set (S1), the effect of fiber content on the flexural behavior of the flat slab was considered. Therefore, four slab specimens were cast, one of which was considered as a control specimen with no fiber content, while the other three included fibers at 0.5, 1, and 1.5 percent of the total concrete volume. The second series of experiments studied the flexural behavior of flat slabs (S2) with an opening of 15 cm × 15 cm. The first specimen contained nil polyolefin, while the second included 1% polyolefin. In the third set (S3), consideration was taken for 0 and 1% of Polyolefin to realize the shear behavior of the flat slab. The increase in polyolefin fiber content from 0 to 1.5% (for slab set 1) will decrease the deflection from 4.5 mm to 2.3 mm, with an average of 3.58 mm, which is close to the deflection of a 1% polyolefin fiber specimen. Three dimensional models for the tested slabs were simulated numerically via ABAQUS software program. The ratio of the maximum deflection between the experimental and the numerical outcomes were varied with a range of 1.01 to 1.28, with an average of 1.14.
1 February 2016 in Engineering and Technology Journal
Hollow Bridge section inspection was carried out in this study and different reasons may cause major failure of bridge. The field inspection of bridge structural elements has been paying more attention of engineering academic researchers. The bridge has been exposed to fire accident in additional to the excessive load and environmental factors effects. This study dedicated for inspection the White River Bridge elements (Bai xi da Qiao/ China) including the essential damage in main girder , concrete spalling, deformation due to deflection and excessive stress and strain, deck slab and concrete cover, steel corrosion…..etc. The analysis of field test evaluates the performance of whole structure of bridge element under static load test. The investigation results shows that the bridge has minor defects through the substructures such as there is no major corrosion of reinforcement and the concrete in a good condition. The upper structure depending on analysis field test of deflection and strain at the critical section, that the main girder has no enough capacity and need to be strengthened.
30 April 2022 in Periodicals of Engineering and Natural Sciences (PEN)
Cement board reinforced with basalt fibers were prepared by using polymer compounds, 5% of water-based of isocyanate-polyester polyol prepolymer blend was used as a fixed percentage, and the rates of basalt fıber used were 5%, 7.5%, 10%, 12.5%, and for each of them used water/cement ratios (W/C) as 1.4, 1, 0.75, 0.4, and 0.5 respectively. The sample cured for 28 days, and the mechanical and physical properties of cement fiberboard were greatly improved due to additional fibers in cement compounds, the tests procedures of properties were carried out according to ASTM standard c-1185. It results reveals that 12.5% is the best percentage, in bending resistance, water absorption percentage, and the moisture content have improved, but it showed less thermal conductivity compared to other ratios, furthermore the compressive strength was improved. It is essential to indicate when increasing the polymer ratio, leads to a certain decrease in mechanical properties but improves the wetting surface of the basalt fibers and adhesion to cement. Therefore, a 5% polymers ratio chooses and the basalt fıber mix proportions changed to enhance the mechanical and physical properties of fiber board.
The connection between the space frame and its supporting columns is a critical aspect of structural design. The way these two elements are joined significantly influences the overall stability, load transfer, and behavior of the entire structure. This study investigates the seismic behavior of composite double-layer space frames with reinforced concrete (RC) slabs under three alternative support configurations: simple point supports, inverted-pyramid supports, and crosshead-beam supports. A detailed finite element (FE) model was developed in ABAQUS to conduct a nonlinear time-history analysis under recorded earthquake excitation. The selected record captures the temporal variation in ground motion and enables an accurate assessment of structural response under dynamic loading. The Concrete Damage Plasticity model was incorporated into the analysis of the concrete slab. The steel was modeled using an elastic–plastic material behavior to mimic the formation of plastic hinges. Maximum lateral displacements, base shear forces, and hysteretic behavior were studied to evaluate the comparative performance of the systems. The results show that the inverted-pyramid configuration reduced vertical (Y-direction) displacement by 33.6% compared to the simple point support. At the same time, the crosshead-beam system exhibited similar levels of vertical displacement. However, it exhibited significantly enhanced energy-dissipation capacity, with hysteretic force ranges up to 1250 kN, compared to approximately 922 kN and 860 kN for the simple point and inverted configurations, respectively. In the X-direction (lateral displacement), the simple support and inverted-pyramid cases showed comparable responses, whereas the crosshead-beam configuration exhibited greater displacement, indicating reduced lateral stiffness. Overall, the results of this study indicate that the inverted-pyramid system improves displacement control, and the crosshead-beam configuration provides superior hysteretic energy dissipation. These findings highlight the importance of selecting appropriate support configurations in the seismic design of composite space frame systems.