Abdulamir Atalla Almayah

Prof. Dr. Abdulamir Atalla Almayah

Civil Engineering, University of Basrah, Basra, Iraq
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2024 in Eng
Verified
Journal Article
Open access
PDF file
NANoor Alhuda Sami Aljabbri
Noor Alhuda Sami Aljabbri
Abdulamir Atalla AlmayahAbdulamir Atalla Almayah
Abdulamir Atalla Almayah
FMFareed Hameed Majeed
Fareed Hameed Majeed
Strength enhancement of non-seismic concrete beam–column joints (NSCBCJs) via carbon fiber-reinforced polymer composites (CFRPCs) integration has become a viable strategy. However, the implementation of these NSCBCJs without transverse reinforcement shows poor performance during earthquakes in seismic locations. Thus, strengthening the anti-seismic performance of NSCBCJs to meet the acceptance criteria of ACI 374.1-05 is fundamentally significant. Yet, in addition to limited experimental results, only a few numerical studies based on the finite element model have been performed to determine the anti-seismic behavior of NSCBCJs. Consequently, the stress contribution of CFRPCs to NSCBCJs is not clearly understood. Therefore, we used a finite element model to examine the strength contribution of CFRPCs to NSCBCJs. The performance of the proposed finite element model was validated using the experimental results, demonstrating a good agreement between them. It was shown that the strength of NSCBCJs was improved due to CFRPC incorporation, thereby achieving compliance with the seismic requirements of ACI 374.1-05. In addition, CFRPCs presence could enhance the confinement, reduce the deformation of the NSCBCJs and, thus, decrease their stiffness and strength degradation, while simultaneously improving the energy dissipation.

1 September 2025 in Civil Engineering Journal
Verified
Journal Article
Open access
PDF file
KNKadhim Zuboon Naser
Kadhim Zuboon Naser
HAHussein A. Al-Gusab
Hussein A. Al-Gusab
ATAnsam Zuhair Thamer
Ansam Zuhair Thamer
Abdulamir Atalla AlmayahAbdulamir Atalla Almayah
Abdulamir Atalla Almayah
MMMuthana Sh. Mahdi
Muthana Sh. Mahdi
MAMazin D. Abdullah
Mazin D. Abdullah
This study investigates the structural performance of semi-precast concrete slabs (SPCSs), an innovative hybrid construction system that integrates factory-produced precast concrete units with a cast-in-place (CIP) concrete topping to create a composite structural element. This system offers notable advantages in terms of construction acceleration, improved quality control, and reduced labor requirements, as the precast unit serves as both a load-bearing component and a permanent formwork. To evaluate the structural behavior of the SPCSs, an experimental program was conducted on seven full-scale, one-way slab specimens with varying span lengths (4.75 m and 6.0 m), precast unit thicknesses (80 mm and 100 mm), and shear connector geometries (rectangular and triangular). A control slab without shear connectors was also tested to establish a baseline for comparison. The results demonstrated that the inclusion of shear connectors significantly enhanced structural performance. Specifically, the ultimate load capacity increased by 186.4%, and the cracking load increased by 220% compared to the control specimen. Rectangular connectors proved more effective than triangular ones in minimizing interface slip and enhancing ductility. The initial stiffness increased by 163.95%, while the energy dissipation capacity improved by 411.35%. Although variations in span length and topping thickness had relatively minor effects, the presence and geometry of shear connectors played a decisive role in ensuring effective composite action. All reinforced slabs exhibited flexural failure modes, indicating strong bonding and interaction between the precast and cast-in-place (CIP) concrete layers, whereas the control slab experienced premature failure due to interlayer debonding. Theoretical equations based on ACI 318-19 were used to estimate the nominal flexural capacities of the hybrid SPCS slabs, showing reliable agreement with the experimental results. These findings demonstrated the importance of shear connector design in maximizing the load-bearing capacity, ductility, and structural stiffness of SPCS systems under both service and extreme loading conditions.

27 July 2026 in Buildings
Verified
Journal Article
Open access
PDF file
ATAnsam Zuhair Thamer
Ansam Zuhair Thamer
AAAbdulameer AL-Mubarak
Abdulameer AL-Mubarak
HAHussein A. A. Al-Gusab
Hussein A. A. Al-Gusab
HBHaleem Al Bremani
Haleem Al Bremani
Abdulamir Atalla AlmayahAbdulamir Atalla Almayah
Abdulamir Atalla Almayah
The connection between the space frame and its supporting columns is a critical aspect of structural design. The way these two elements are joined significantly influences the overall stability, load transfer, and behavior of the entire structure. This study investigates the seismic behavior of composite double-layer space frames with reinforced concrete (RC) slabs under three alternative support configurations: simple point supports, inverted-pyramid supports, and crosshead-beam supports. A detailed finite element (FE) model was developed in ABAQUS to conduct a nonlinear time-history analysis under recorded earthquake excitation. The selected record captures the temporal variation in ground motion and enables an accurate assessment of structural response under dynamic loading. The Concrete Damage Plasticity model was incorporated into the analysis of the concrete slab. The steel was modeled using an elastic–plastic material behavior to mimic the formation of plastic hinges. Maximum lateral displacements, base shear forces, and hysteretic behavior were studied to evaluate the comparative performance of the systems. The results show that the inverted-pyramid configuration reduced vertical (Y-direction) displacement by 33.6% compared to the simple point support. At the same time, the crosshead-beam system exhibited similar levels of vertical displacement. However, it exhibited significantly enhanced energy-dissipation capacity, with hysteretic force ranges up to 1250 kN, compared to approximately 922 kN and 860 kN for the simple point and inverted configurations, respectively. In the X-direction (lateral displacement), the simple support and inverted-pyramid cases showed comparable responses, whereas the crosshead-beam configuration exhibited greater displacement, indicating reduced lateral stiffness. Overall, the results of this study indicate that the inverted-pyramid system improves displacement control, and the crosshead-beam configuration provides superior hysteretic energy dissipation. These findings highlight the importance of selecting appropriate support configurations in the seismic design of composite space frame systems.

24 January 2024 in International Academic Journal of Science and Engineering
Verified
Journal Article
Open access
PDF file
NANoor Alhuda Sami Aljabbri
Noor Alhuda Sami Aljabbri
Abdulamir Atalla AlmayahAbdulamir Atalla Almayah
Abdulamir Atalla Almayah
FMFareed Hameed Majeed
Fareed Hameed Majeed
In the seismic load-facilitated (vertical and lateral) reinforced concrete beam-column (RCBC), strong linkages are vital to protect the integrity of any civil structure foundation. Compared to other structural components, these joints often collapse during an earthquake in the seismic locations due to plastic-hinge zone mechanism. Most of the earlier reports on these issues mainly focused on two-dimensional RCBC joints and seldom emphasized on the need of three-dimensional RCBC linkages. Based on this fact, we critically overviewed several recent-state-of-the-art studies carried out on the improvement of RCBC linkages subjected to seismic loading. A careful evaluation of these articles revealed that the factors like shear strength (SS), failure, processing and selection of materials, as well as methods of strengthening (MS) of these RCBC joints are responsible for the collapse. It is established that for low axial load the ductility and bending resistance of the column must be enhanced to strengthen the RCBC links, enabling the diagonal strips or bars more robust than vertical ones and vice versa. Briefly, this article may provide the taxonomy for navigating the researchers into this field, leading to future sustainable development in the civil engineering construction sectors.