Abdulameer AL-Mubarak

Dr. Abdulameer AL-Mubarak


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2024 in Iranian Journal of Science and Technology, Transactions of Civil Engineering
Verified
Journal Article
Closed access
PDF file
AKAmin Khajehdezfuly
Amin Khajehdezfuly
YYYahya Mohammad Younus
Yahya Mohammad Younus
AKAbdolghafour Khademalrasoul
Abdolghafour Khademalrasoul
AAAbdulameer AL-Mubarak
Abdulameer AL-Mubarak

2 October 2019 in Kufa Journal of Engineering
Verified
Journal Article
Open access
PDF file
AAAbdulameer AL-Mubarak
Abdulameer AL-Mubarak
In this paper, the finite element ANSYS software was used to study the seismic behavior of cylindrical fuel storage tanks in west of Basra governorate. Single and group tanks are analyzed under free vibration (empty and full tanks) and under the El-Centro earthquake component for an impulsive case and full tank with fuel. The interaction between tanks wall and internal fuel was considered. The study includes Hoop forces, bending moment, shear force, horizontal displacement and hydrodynamic pressure. Also, the reflection point for bending moment and shear force for tank wall is estimated. This study shows that the response of a single tank is larger than group tanks, and the hoop force decreases about (10-17) %, while the pressure and displacement decrease about (5-10) %, and the shear force and bending moment are decreased about (37-42) %. The increase in tank diameter leads to increase the response of tank. The Time has come to the understanding that the fixed support of tank is more stable than hinge support.

20 June 2025 in Passer Journal of Basic and Applied Sciences
Verified
Journal Article
Open access
PDF file
AAAbdulameer AL-Mubarak
Abdulameer AL-Mubarak
RQRafi Mohammed Qasim
Rafi Mohammed Qasim
AYAyad Abdulkhaleq Yahya
Ayad Abdulkhaleq Yahya
Piles foundation has been widely used to support and transfer loads to deeply strong soil. Piles have been used as foundation for tall building, tower, onshore structure, offshore structure and bridge. This paper investigates the behavior of cast in place pile under harmonic torsional loading. This study investigates the effect of pile diameter, steel tubular wall thickness, load eccentricity, torque magnitude and concrete compressive strength on the response of single pile to harmonic torsional loading. The pile response includies displacement, shear force, bending moment, torsional moment, principal stresses, skin friction, Von miss stress and soil reaction. ABAQUS Software is used to perform the numerical simulation. The pile has elastoplastic properties; similarly, the clay soil is modeled as an elastoplastic material described by the cam- clay model. The procedure used in this investigation involves fixing four parameters and varying one, such as fixing the steel tubular wall thickness, load eccentricity, torque magnitude, concrete compressive strength, and change pile diameter in order to study pile 's response. The results show that increasing the pile diameter and wall thickness leads to a decrease in the displacement by 24% , 19% respectively, while an increase in applied torque results in a 27% increase in displacement. also, It is also found that the compressive strength of concrete has a smaller effect on the response of the pile.

30 March 2025 in Al-Qadisiyah Journal for Engineering Sciences
Verified
Journal Article
Open access
PDF file
AAAbdulameer AL-Mubarak
Abdulameer AL-Mubarak
Most water stations use concrete tanks to store water, and the tanks may be above or below ground level. In designing tanks, many engineering requirements are taken into account to ensure the structural safety of the tank and the absence of water leakage. The research aims to study the response of different shapes of concrete tanks (square, rectangular, circular, and hexagonal), that based on clay soil and subjected to an earthquake wave (type El Centro), by studying some engineering variables related to tanks and soil. ABAQUS program was used to analyze the tanks, and used different analysis cases like Dynamic Explicit, geotechnical and soil analysis. The study concluded that there are advantages and disadvantages for each of the studied shapes. It is preferable to use circular tanks because they have a high resistance to shear forces, bending moments, stresses, lateral strength, and have small soil consolidation compare with the other tanks, but the bad characteristic is that cracks are high. Also, It is also preferable to avoid using a rectangular tank due to its poor response to seismic loads.

27 July 2026 in Buildings
Verified
Journal Article
Open access
PDF file
ATAnsam Zuhair Thamer
Ansam Zuhair Thamer
AAAbdulameer AL-Mubarak
Abdulameer AL-Mubarak
HAHussein A. A. Al-Gusab
Hussein A. A. Al-Gusab
HBHaleem Al Bremani
Haleem Al Bremani
Abdulamir Atalla AlmayahAbdulamir Atalla Almayah
Abdulamir Atalla Almayah
The connection between the space frame and its supporting columns is a critical aspect of structural design. The way these two elements are joined significantly influences the overall stability, load transfer, and behavior of the entire structure. This study investigates the seismic behavior of composite double-layer space frames with reinforced concrete (RC) slabs under three alternative support configurations: simple point supports, inverted-pyramid supports, and crosshead-beam supports. A detailed finite element (FE) model was developed in ABAQUS to conduct a nonlinear time-history analysis under recorded earthquake excitation. The selected record captures the temporal variation in ground motion and enables an accurate assessment of structural response under dynamic loading. The Concrete Damage Plasticity model was incorporated into the analysis of the concrete slab. The steel was modeled using an elastic–plastic material behavior to mimic the formation of plastic hinges. Maximum lateral displacements, base shear forces, and hysteretic behavior were studied to evaluate the comparative performance of the systems. The results show that the inverted-pyramid configuration reduced vertical (Y-direction) displacement by 33.6% compared to the simple point support. At the same time, the crosshead-beam system exhibited similar levels of vertical displacement. However, it exhibited significantly enhanced energy-dissipation capacity, with hysteretic force ranges up to 1250 kN, compared to approximately 922 kN and 860 kN for the simple point and inverted configurations, respectively. In the X-direction (lateral displacement), the simple support and inverted-pyramid cases showed comparable responses, whereas the crosshead-beam configuration exhibited greater displacement, indicating reduced lateral stiffness. Overall, the results of this study indicate that the inverted-pyramid system improves displacement control, and the crosshead-beam configuration provides superior hysteretic energy dissipation. These findings highlight the importance of selecting appropriate support configurations in the seismic design of composite space frame systems.

19 March 2025 in Asian Journal of Civil Engineering
Verified
Journal Article
Closed access
PDF file
AAAbdulameer AL-Mubarak
Abdulameer AL-Mubarak
YYYahya Mohammad Younus
Yahya Mohammad Younus