Even in modern times, the popularity level of medicinal plants and herbal medicines in therapy is still high. The World Health Organization estimates that 80% of the population in developing countries uses these types of remedies. Even though herbal medicine products are usually perceived as low risk, their potential health risks should be carefully assessed. Several factors can cause the toxicity of herbal medicine products: plant components or metabolites with a toxic potential, adulteration, environmental pollutants (heavy metals, pesticides), or contamination of microorganisms (toxigenic fungi). Their correct evaluation is essential for the patient’s safety. The toxicity assessment of herbal medicine combines in vitro and in vivo methods, but in the past decades, several new techniques emerged besides conventional methods. The use of omics has become a valuable research tool for prediction and toxicity evaluation, while DNA sequencing can be used successfully to detect contaminants and adulteration. The use of invertebrate models (Danio renio or Galleria mellonella) became popular due to the ethical issues associated with vertebrate models. The aim of the present article is to provide an overview of the current trends and methods used to investigate the toxic potential of herbal medicinal products and the challenges in this research field.
Periodontitis is one of the most common immune-mediated inflammatory conditions resulting in progressive destruction of periodontium. Metalloproteinase-9 (MMP-9), an enzyme that is involved in the degradation of gelatin and collagen and present in the gingival crevicular fluid, is markedly increased in periodontitis. The aim of the study is to evaluate the effects of periodontal treatment either alone or in combination with orthodontic treatment on MMP-9 levels. In this study, 60 individuals were subjected to periodontal treatment (PD) or periodontal treatment combined with orthodontic treatment (POD). Both periodontal and periodontal plus orthodontic treatments significantly improved clinical parameters and lowered MMP-9 levels compared to control group. However, the combination of periodontal with orthodontic treatment further improved clinical parameters and enhanced the lowering effect on MMP-9 levels compared to periodontal or control groups alone. Finally, the degree of malocclusion significantly affected the effect of the treatment on MPP-9 levels with PD treatment having the most pronounced effect. We concluded that salivary MMP-9 can serve to accurately predict the level of inflammation in affected periodontal tissues during orthodontic treatment that is also associated with the type of malocclusion, making it a viable diagnosis tool in monitoring the progression of the periodontium during orthodontic treatment.
Inlay-retained dental bridges can be a viable minimally invasive alternative when patients reject the idea of implant therapy or conventional retained full-coverage fixed dental prostheses, which require more tooth preparation. Inlay-retained dental bridges are indicated in patients with good oral hygiene, low susceptibility to caries, and a minimum coronal tooth height of 5 mm. The present study aims to evaluate, through the finite element method (FEM), the stability of these types of dental bridges and the stresses on the supporting teeth, under the action of masticatory forces. The analysis revealed the distribution of the load on the bridge elements and on the retainers, highlighting the areas of maximum pressure. The results of our study demonstrate that the stress determined by the loading force cannot cause damage to the prosthetic device or to abutment teeth. Thus, it can be considered an optimal economical solution for treating class III Kennedy edentation in young patients or as a provisional pre-implant rehabilitation option. However, special attention must be paid to its design, especially in the connection area between the bridge elements, because the connectors and the retainers represent the weakest parts.
Electronic nicotine delivery systems first appeared on the market in 2003 and have been promoted as healthier alternatives to conventional tobacco cigarettes. The rapid evolution of technology for these products generated a wide variety of models, and electronic cigarettes have quickly gained worldwide popularity. However, research regarding the effects of both short-term and long-term exposure revealed a wide variety of potential negative effects on human health, and the first system to be affected by these electronic smoking devices is the oral cavity. This review makes an up-to-date extensive presentation of the possible mechanisms that associate electronic cigarette smoking with increased prevalence and progression of oral cancer. Oxidative stress, inflammation response, and DNA damage are the main mechanisms that explain e-cigarettes’ cytotoxicity, but there are still questions to be answered. At present, tens of thousands of e-liquids are available, with distinct compositions, which makes the research even more challenging. Another aspect approached in the present paper is the effect of nicotine on chemotherapy drug resistance. Nicotine activates nicotinic acetylcholine receptors, consecutively inhibiting apoptosis, increasing tumor cells proliferation and survival, and reducing the effects of chemotherapy drugs.
Background and Objectives: The surface condition of the materials that are used for temporary prostheses influences their microbial colonization, with a direct impact on the oral tissues. This study aims at a comparative analysis of three types of resins for temporary bridges using conventional and digital technologies. The attention was focused on the analysis of the surface characteristics and mechanical strength of these materials. Materials and Methods: The surface condition was assessed for three distinct materials both before and after polishing- heat-curing resin Superpont C + B (SpofaDental, Jicin, Czech Republic) used unconventional technology, Zotion dental milling polymethyl methacrylate (PMMA) block (Zotion, Chongqing, China) for provisional crowns/bridges used in digital subtractive technologies and Freeprint Temp (Detax GmbH & Co. KG, Ettlingen, Germany) resin for temporary crowns and bridges that are used in 3D printing technologies. The two-way ANOVA analysis indicated that polishing leads to a statistically significant increase in roughness coefficients for all the three resins that were tested (p < 0.001). While the highest roughness coefficients were displayed in the 3D cured sample, the largest decrease was reported by the milled sample Results: The results revealed that surface roughness was significantly influenced by both the type of resin that was used (p < 0.001) and the treatment that was induced by finishing and polishing (p < 0.001). Similar p-values were obtained for each of the three resins. Conclusions: The results demonstrated a significant optimization of the surfaces after finishing and polishing and statistically significant differences between the surface parameters and the mechanical properties of the samples. The low values of the roughness and the acceptable values of the mechanical resistance for the conventional samples indicate these materials for the long-term temporary bridge’s realization, allowing the correct restoration of the functions and the rehabilitation at the oral level.
The growing popularity of electronic cigarettes has raised several public health concerns, including the risks associated with heavy metals exposure via e-liquids and vapors. The purpose of this study was to determine, using atomic absorption spectrometry, the concentrations of Pb, Ni, Zn, and Co in some commercially available e-liquid samples from Romania immediately after purchase and after storage in clearomizers. Lead and zinc were found in all investigated samples before storage. The initial concentrations of Pb ranged from 0.13 to 0.26 mg L−1, while Zn concentrations were between 0.04 and 0.07 mg L−1. Traces of nickel appeared in all investigated e-liquids before storage but in very small amounts (0.01–0.02 mg L−1). Co was below the detection limits. We investigated the influence of the storage period (1, 3, and 5 days), storage temperature (22 °C and 40 °C), and type of clearomizer. In most cases, the temperature rise and storage period increase were associated with higher concentrations of heavy metals. This confirms that storage conditions can affect metal transfer and suggests that the temperature of storage is another parameter that can influence this phenomenon.