Electronic nicotine delivery systems first appeared on the market in 2003 and have been promoted as healthier alternatives to conventional tobacco cigarettes. The rapid evolution of technology for these products generated a wide variety of models, and electronic cigarettes have quickly gained worldwide popularity. However, research regarding the effects of both short-term and long-term exposure revealed a wide variety of potential negative effects on human health, and the first system to be affected by these electronic smoking devices is the oral cavity. This review makes an up-to-date extensive presentation of the possible mechanisms that associate electronic cigarette smoking with increased prevalence and progression of oral cancer. Oxidative stress, inflammation response, and DNA damage are the main mechanisms that explain e-cigarettes’ cytotoxicity, but there are still questions to be answered. At present, tens of thousands of e-liquids are available, with distinct compositions, which makes the research even more challenging. Another aspect approached in the present paper is the effect of nicotine on chemotherapy drug resistance. Nicotine activates nicotinic acetylcholine receptors, consecutively inhibiting apoptosis, increasing tumor cells proliferation and survival, and reducing the effects of chemotherapy drugs.
Background and Objectives: The surface condition of the materials that are used for temporary prostheses influences their microbial colonization, with a direct impact on the oral tissues. This study aims at a comparative analysis of three types of resins for temporary bridges using conventional and digital technologies. The attention was focused on the analysis of the surface characteristics and mechanical strength of these materials. Materials and Methods: The surface condition was assessed for three distinct materials both before and after polishing- heat-curing resin Superpont C + B (SpofaDental, Jicin, Czech Republic) used unconventional technology, Zotion dental milling polymethyl methacrylate (PMMA) block (Zotion, Chongqing, China) for provisional crowns/bridges used in digital subtractive technologies and Freeprint Temp (Detax GmbH & Co. KG, Ettlingen, Germany) resin for temporary crowns and bridges that are used in 3D printing technologies. The two-way ANOVA analysis indicated that polishing leads to a statistically significant increase in roughness coefficients for all the three resins that were tested (p < 0.001). While the highest roughness coefficients were displayed in the 3D cured sample, the largest decrease was reported by the milled sample Results: The results revealed that surface roughness was significantly influenced by both the type of resin that was used (p < 0.001) and the treatment that was induced by finishing and polishing (p < 0.001). Similar p-values were obtained for each of the three resins. Conclusions: The results demonstrated a significant optimization of the surfaces after finishing and polishing and statistically significant differences between the surface parameters and the mechanical properties of the samples. The low values of the roughness and the acceptable values of the mechanical resistance for the conventional samples indicate these materials for the long-term temporary bridge’s realization, allowing the correct restoration of the functions and the rehabilitation at the oral level.
Background and Objectives: Orthodontic treatment aims to enhance dental aesthetics and function, yet many patients report dissatisfaction. This study was designed with the following objectives: To assess overall patient satisfaction during active orthodontic treatment; to identify key psychosocial and clinical predictors of satisfaction, including self-confidence, social experiences, and cost perception; to evaluate the impact of orthodontist–patient communication on satisfaction and perceived treatment outcomes; to explore the relationship between aesthetic improvement and willingness to undergo treatment again. Materials and Methods: A cross-sectional survey was conducted using structured questionnaires to assess satisfaction, pain perception, treatment expectations, and communication quality. Statistical analyses, including correlations and regression models, were used to identify predictors of satisfaction. The study included 450 orthodontic patients from the north-eastern region of Romania, undergoing active treatment at the time of data collection. Results: The strongest predictor of satisfaction was improved self-confidence and smile aesthetics (r = 0.62). Effective communication with orthodontists significantly increased satisfaction (r = 0.58, p = 0.002), while perceived high costs had a negative impact (r = −0.41). Pain and discomfort were common, with 90% of patients experiencing treatment-related pain, leading to reduced compliance. Social embarrassment due to braces also contributed to dissatisfaction (r = −0.47). Conclusions: Patient satisfaction with orthodontic treatment is primarily influenced by aesthetic improvements and effective communication. While enhanced smile perception boosts confidence, financial concerns and social discomfort may negatively affect the overall experience. Improving accessibility to treatment and providing comprehensive patient support are essential for optimizing patient satisfaction.
Background and Objectives: Acrylic resins remain the materials of choice for removable prosthesis due to their indisputable qualities. The continuous evolution in the field of dental materials offers practitioners today a multitude of therapeutic options. With the development of digital technologies, including both subtractive and additive methods, workflow has been considerably reduced and the precision of prosthetic devices has increased. The superiority of prostheses made by digital methods compared to conventional prostheses is much debated in the literature. Our study’s objective was to compare the mechanical and surface properties of three types of resins used in conventional, subtractive, and additive technologies and to determine the optimal material and the most appropriate technology to obtain removable dentures with the highest mechanical longevity over time. Materials and Methods: For the mechanical tests, 90 samples were fabricated using the conventional method (heat curing), CAD/CAM milling, and 3D printing technology. The samples were analyzed for hardness, roughness, and tensile tests, and the data were statistically compared using Stata 16.1 software (StataCorp, College Station, TX, USA). A finite element method was used to show the behavior of the experimental samples in terms of the crack shape and its direction of propagation. For this assessment the materials had to be designed inside simulation software that has similar mechanical properties to those used for obtaining specimens for tensile tests. Results: The results of this study suggested that CAD/CAM milled samples showed superior surface characteristics and mechanical properties, comparable with conventional heat-cured resin samples. The propagation direction predicted by the finite element analysis (FEA) software was similar to that observed in a real-life specimen subjected to a tensile test. Conclusions: Removable dentures made from heat-cured resins remain a clinically acceptable option due to their surface quality, mechanical properties, and affordability. Three-dimensional printing technology can be successfully used as a provisional or emergency therapeutic solution. CAD/CAM milled resins exhibit the best mechanical properties with great surface finishes compared to the other two processing methods.
Orthodontic mini-implants are devices used for anchorage in various orthodontic treatments. We conducted a pilot study which aimed to observe preliminary trends regarding the impact of heat treatment on the elastic modulus of Ti6Al4V alloy and stainless steel 316L mini-implants. The initial phase involved testing the impact of heat treatment on the mechanical properties of Ti6Al4V alloy and stainless steel 316L mini-implants. Material and methods: Ten self-drilling mini-implants sourced from two distinct manufacturers (Jeil Medical Corporation® and Leone®) with dimensions of 2.0 mm diameter and 10 mm length were tested. They were separated into two material groups: Ti6Al4V and 316L. Using the CETRUMT-2 microtribometer equipment, indentation testing was conducted employing a diamond-tipped Rockwell penetrator at a constant force of 4.5 N. Results: Slight differences were observed in the elastic modulus of the Ti6Al4V alloy (103.99 GPa) and stainless steel 316L (203.20 GPa) compared to natural bone. The higher elastic moduli of these materials indicate that they are stiffer, which could potentially lead to stress-shielding phenomena and bone resorption. Heat treatment resulted in significant changes in mechanical properties, including elastic modulus reductions of approximately 26.14% for Ti6Al4V and 24.82% for 316L, impacting their performance in orthodontic applications. Conclusion: Understanding the effects of heat treatment on these alloys is crucial for optimizing their biomechanical compatibility and longevity in orthodontic treatment. To fully evaluate the effects of heat treatment on mini-implants and to refine their design and efficacy in clinical practice, further research is needed.
Objective: This study aims to investigate the mechanical behavior of titanium (Ti6Al4V) mini-implants (MIs) under varying orthodontic forces using finite element analysis (FEA) and to evaluate their performance and durability under realistic clinical conditions. Optimal orthodontic forces significantly influence the structural integrity and functional longevity of MIs while minimizing adverse effects on surrounding bone tissues. Materials and Methods: A commercially available MI (diameter: 2.0 mm, length: 12 mm) was modeled using FEA. The mandible geometry was obtained using computed tomography (CT) scanning, reconstructed in 3D using SpaceClaim software 2023.1, and discretized into 10-node tetrahedral elements in ANSYS Workbench. Material properties were assigned based on the existing literature, and the implant–bone interaction was simulated using a nonlinear frictional contact model. Orthodontic forces of 2 N and 10 N, inclined at 30°, were applied to simulate clinical loading conditions. Total displacement, von Mises stresses, equivalent strains, fatigue life, and safety factors were analyzed to assess the implant’s mechanical performance. Results: At 2 N, the MI demonstrated minimal displacement (0.0328 mm) and sustained approximately 445,000 cycles under safe fatigue loading conditions, with a safety factor of 4.8369. At 10 N, the implant’s lifespan was drastically reduced to 1546 cycles, with significantly elevated stress (6.468 × 105 MPa) and strain concentrations, indicating heightened risks of mechanical failure and bone damage. The findings revealed the critical threshold beyond which orthodontic forces compromise implant stability and peri-implant bone health. Conclusions: This study confirms that maintaining orthodontic forces within an optimal range, approximately 2 N, is essential to prolong MI lifespan and preserve bone integrity. Excessive forces, such as 10 N, lead to a rapid decline in durability and increased risks of failure, emphasizing the need for calibrated force application in clinical practice. These insights provide valuable guidance for enhancing MI performance and optimizing orthodontic treatment outcomes.