Natalia Lastovets

Dr. Natalia Lastovets

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in Building and Environment
Verified
Journal Article
Closed access
Risto KosonenRisto Kosonen
Risto Kosonen
NLNatalia Lastovets
Natalia Lastovets
PMPanu Mustakallio
Panu Mustakallio
Guilherme Carrilho Da GraçaGuilherme Carrilho Da Graça
Guilherme Carrilho Da Graça
NMNuno M. Mateus
Nuno M. Mateus
MRMarko Rosenqvist
Marko Rosenqvist

27 March 2019 in International Journal of Ventilation
Verified
Journal Article
Closed access
NLNatalia Lastovets
Natalia Lastovets
Risto KosonenRisto Kosonen
Risto Kosonen
PMPanu Mustakallio
Panu Mustakallio
JJJuha Jokisalo
Juha Jokisalo
ALAngui Li
Angui Li
An accurate temperature gradient calculation is essential for displacement ventilation (DV) system design, since it directly relates to the calculation of supply air flow rate. Several simplified nodal models were developed and implemented in the various building simulation programmes to estimate the temperature stratification in rooms with displacement ventilation. However, the most commonly used models do not take into account the types and locations of the heat loads in rooms with DV. As a result, the calculated air temperature in the occupied zone can defer from the real one by 2–3 °C, which causes poor thermal comfort and inadequate sizing of the ventilation and cooling systems. In the present study, the nodal model was proposed to provide a simplified technique to predict the vertical temperature gradient in rooms with DV. In addition, the effect of the room height and locations of the indoor heat sources were studied for the typical office environment. The measurement data were compared with the existing nodal models and the proposed nodal model in terms of predicting the occupied zone temperatures. The presented nodal model demonstrates an accurate calculation of the temperature gradient for the typical heat loads and combinations of them.

9 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
YYYat Huang Yau
Yat Huang Yau
Umair AhmedUmair Ahmed
Umair Ahmed
ARAltaf Hussain Rajpar
Altaf Hussain Rajpar
NLNatalia Lastovets
Natalia Lastovets
A variable refrigerant flow integrated stratum ventilation (VRF-SV) system was proposed as an energy efficient substitute for conventional central cooling systems for buildings. The novel system provided conditioned air to enclosed spaces with high indoor air quality and thermal comfort. This study investigated the effects of different types of ASTDs on the performance of the VRF-SV hybrid system. The performance was experimentally evaluated with five air terminal types, including bar grille, double deflection grille, jet slot, perforated and drum louver diffusers. The evaluation was carried out using standard indices: temperature and velocity distribution, airflow pattern, effective draft temperature (EDT), air distribution performance index (ADPI), thermal sensation vote and comfort feedback survey. The results indicated that the ASTD type had a significant impact on airflow pattern. Furthermore, the bar grille diffuser provided the occupants with greater thermal comfort and acceptable indoor environment. Almost all the EDT values determined in the breathing zone in the case with bar grille diffuser found under the satisfactory range, i.e., −1.2 < K < 1.2. Based on these values, the ADPI for bar grille diffuser was calculated as 92.8%. Thus, the bar grille diffuser is recommended to be installed with the VRF-SV hybrid system in buildings.

6 July 2020 in International Journal of Ventilation
Verified
Journal Article
Closed access
NLNatalia Lastovets
Natalia Lastovets
KSKai Sirén
Kai Sirén
RKRisto Kosonen
Risto Kosonen
JJJuha Jokisalo
Juha Jokisalo
SKSimo Kilpeläinen
Simo Kilpeläinen
An accurate temperature gradient calculation is essential for displacement ventilation (DV) system design since it directly relates to thecalculation of the required supply airflow rate. Inaccurate temperature prediction can cause poor thermal comfort and wrong sizing of the ventilation and cooling systems. A heat balance-based method is usually applied in displacement ventilation (DV) design when overheating is the primary indoor climate concern. The temperature gradient in DV systems is usually calculated with lumped-parameter nodal models. Several simplified nodal models were developed and implemented in the various building simulation software to estimate the temperature stratification in rooms with DV. Recent studies reveal that the multi-nodal models provide the most accurate temperature gradient prediction. However, the majority of dynamic calculation methods assumes either complete mixing of zone air or linearised temperature gradient. The present study introduces the dynamic temperature gradient model for DV and investigates the effect of thermal mass on the temperature stratification. The model was validated with the experimental results of a lecture room with displacement ventilation. The room air temperature measurements were conducted during three weeks at 20 different heights. The supply air temperature and occupancy rate were recorded during each scheduled lecture. The developed dynamic nodal model is able to calculate the air temperatures in the occupied zone accurately. The effect of the thermal mass and changing heat gains on the room air temperature stratification is analysed for the lecture room with DV.

7 November 2020 in Building Simulation
Verified
Journal Article
Open access
PDF file
NLNatalia Lastovets
Natalia Lastovets
RKRisto Kosonen
Risto Kosonen
JJJuha Jokisalo
Juha Jokisalo
A temperature-based method is usually applied in displacement ventilation (DV) design when overheating is the primary indoor climate concern. Different steady-state models have been developed and implemented to calculate airflow rate in rooms with DV. However, in practical applications, the performance of DV depends on potentially dynamic parameters, such as strength, type and location of heat gains and changing heat gain schedule. In addition, thermal mass affects dynamically changing room air temperature. The selected steady-state and dynamic models were validated with the experimental results of a lecture room and an orchestra rehearsal room. Among the presented models, dynamic DV model demonstrated a capability to take into account the combination of dynamic parameters in typical applications of DV. The design airflow rate is calculated for the case studies of dynamic DV design in the modelled lecture room in both dynamic and steady-state conditions. In dynamic conditions of heavy construction in 2–4 hours occupancy periods, the actual airflow rate required could be 50% lower than the airflow rate calculated with the steady-state models. The difference between steady-state and dynamic multi-nodal model is most significant with heavyweight construction and short occupancy period (17%–28%). In cases with light construction, the dynamic DV model provides roughly the same airflow rates for four-hour occupancy period than the Mund’s model calculates. The dynamic model can significantly decrease the design airflow rate of DV, which can result in a reduction of investment costs and electrical consumption of fans.

6 May 2024 in Heliyon
Verified
Journal Article
Open access
IKIlpo Kulmala
Ilpo Kulmala
ATAimo Taipale
Aimo Taipale
ESEnni Sanmark
Enni Sanmark
NLNatalia Lastovets
Natalia Lastovets
PSPiia Sormunen
Piia Sormunen
ASArto Säämänen
Arto Säämänen
We estimated the hourly probability of airborne severe acute respiratory coronavirus 2 (SARS-CoV-2) transmission and further the estimated number of persons at transmission risk in a day care centre by calculating the inhaled dose for airborne pathogens based on their concentration, exposure time and activity. Information about the occupancy and activity of the rooms was collected from day care centre personnel and building characteristics were obtained from the design values. The generation rate of pathogens was calculated as a product of viral load of the respiratory fluids and the emission of the exhaled airborne particles, considering the prevalence of the disease and the activity of the individuals. A well-mixed model was used in the estimation of the concentration of pathogens in the air. The Wells-Riley model was used for infection probability. The approach presented in this study was utilised in the identification of hot spots and critical events in the day care centre. Large variation in the infection probabilities and estimated number of persons at transmission risk was observed when modelling a normal day at the centre. The estimated hourly infection probabilities between the worst hour in the worst room and the best hour in the best room varied in the ratio of 100:1. Similarly, the number of persons at transmission risk between the worst and best cases varied in the ratio 1000:1. Although there are uncertainties in the input values affecting the absolute risk estimates the model proved to be useful in ranking and identifying the hot spots and events in the building and implementing effective control measures.