Giulia Paolani

Dr. Giulia Paolani

IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Emilia-Romagna, Italy
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MSMiriam Santoro
Miriam Santoro
SSSilvia Strolin
Silvia Strolin
GPGiulia Paolani
Giulia Paolani
GGGiuseppe Della Gala
Giuseppe Della Gala
Alessandro BartoloniAlessandro Bartoloni
Alessandro Bartoloni
LSLidia Strigari
Lidia Strigari
In recent decades, artificial intelligence (AI) tools have been applied in many medical fields, opening the possibility of finding novel solutions for managing very complex and multifactorial problems, such as those commonly encountered in radiotherapy (RT). We conducted a PubMed and Scopus search to identify the AI application field in RT limited to the last four years. In total, 1824 original papers were identified, and 921 were analyzed by considering the phase of the RT workflow according to the applied AI approaches. AI permits the processing of large quantities of information, data, and images stored in RT oncology information systems, a process that is not manageable for individuals or groups. AI allows the iterative application of complex tasks in large datasets (e.g., delineating normal tissues or finding optimal planning solutions) and might support the entire community working in the various sectors of RT, as summarized in this overview. AI-based tools are now on the roadmap for RT and have been applied to the entire workflow, mainly for segmentation, the generation of synthetic images, and outcome prediction. Several concerns were raised, including the need for harmonization while overcoming ethical, legal, and skill barriers.

2 March 2023 in Frontiers in Oncology
Verified
Journal Article
Open access
SSSilvia Strolin
Silvia Strolin
MSMiriam Santoro
Miriam Santoro
GPGiulia Paolani
Giulia Paolani
IAIlario Ammendolia
Ilario Ammendolia
AAAlessandra Arcelli
Alessandra Arcelli
LSLidia Strigari
Lidia Strigari
Background: A CE- and FDA-approved cloud-based Deep learning (DL)-tool for automatic organs at risk (OARs) and clinical target volumes segmentation on computer tomography images is available. Before its implementation in the clinical practice, an independent external validation was conducted.Methods: At least a senior and two in training Radiation Oncologists (ROs) manually contoured the volumes of interest (VOIs) for 6 tumoral sites. The auto-segmented contours were retrieved from the DL-tool and, if needed, manually corrected by ROs. The level of ROs satisfaction and the duration of contouring were registered. Relative volume differences, similarity indices, satisfactory grades, and time saved were analyzed using a semi-automatic tool.Results: Seven thousand seven hundred sixty-five VOIs were delineated on the CT images of 111 representative patients. The median (range) time for manual VOIs delineation, DL-based segmentation, and subsequent manual corrections were 25.0 (8.0-115.0), 2.3 (1.2-8) and 10.0 minutes (0.3-46.3), respectively. The overall time for VOIs retrieving and modification was statistically significantly lower than for manual contouring (p<0.001). The DL-tool was generally appreciated by ROs, with 44% of vote 4 (well done) and 43% of vote 5 (very well done), correlated with the saved time (p<0.001). The relative volume differences and similarity indexes suggested a better inter-agreement of manually adjusted DL-based VOIs than manually segmented ones.Conclusions: The application of the DL-tool resulted satisfactory, especially in complex delineation cases, improving the ROs inter-agreement of delineated VOIs and saving time.

13 September 2023 in Cancers
Verified
Journal Article
Open access
PDF file
CCCamelia Alexandra Coada
Camelia Alexandra Coada
MSMiriam Santoro
Miriam Santoro
VZVladislav Zybin
Vladislav Zybin
MSMarco Di Stanislao
Marco Di Stanislao
GPGiulia Paolani
Giulia Paolani
Anna PerroneAnna Perrone
Anna Perrone
Background: Current prognostic models lack the use of pre-operative CT images to predict recurrence in endometrial cancer (EC) patients. Our study aimed to investigate the potential of radiomic features extracted from pre-surgical CT scans to accurately predict disease-free survival (DFS) among EC patients. Methods: Contrast-Enhanced CT (CE-CT) scans from 81 EC cases were used to extract the radiomic features from semi-automatically contoured volumes of interest. We employed a 10-fold cross-validation approach with a 6:4 training to test set and utilized data augmentation and balancing techniques. Univariate analysis was applied for feature reduction leading to the development of three distinct machine learning (ML) models for the prediction of DFS: LASSO-Cox, CoxBoost and Random Forest (RFsrc). Results: In the training set, the ML models demonstrated AUCs ranging from 0.92 to 0.93, sensitivities from 0.96 to 1.00 and specificities from 0.77 to 0.89. In the test set, AUCs ranged from 0.86 to 0.90, sensitivities from 0.89 to 1.00 and specificities from 0.73 to 0.90. Patients classified as having a high recurrence risk prediction by ML models exhibited significantly worse DSF (p-value < 0.001) across all models. Conclusions: Our findings demonstrate the potential of radiomics in predicting EC recurrence. While further validation studies are needed, our results underscore the promising role of radiomics in forecasting EC outcomes.

8 January 2023 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
Valerio Da RosValerio Da Ros
Valerio Da Ros
LOLetizia Oddo
Letizia Oddo
YTYosra Toumia
Yosra Toumia
EGEugenia Guida
Eugenia Guida
SMSilvia Minosse
Silvia Minosse
FDFabio Domenici
Fabio Domenici
This proof-of-concept study lays the foundations for the development of a delivery strategy for radioactive lanthanides, such as Yttrium-90, against recurrent glioblastoma. Our appealing hypothesis is that by taking advantage of the combination of biocompatible polyvinyl alcohol (PVA) microbubbles (MBs) and endovascular radiopharmaceutical infusion, a minimally invasive selective radioembolization can be achieved, which can lead to personalized treatments limiting off-target toxicities for the normal brain. The results show the successful formulation strategy that turns the ultrasound contrast PVA-shelled microbubbles into a microdevice, exhibiting good loading efficiency of Yttrium cargo by complexation with a bifunctional chelator. The selective targeting of Yttrium-loaded MBs on the glioblastoma-associated tumor endothelial cells can be unlocked by the biorecognition between the overexpressed αVβ3 integrin and the ligand Cyclo(Arg-Gly-Asp-D-Phe-Lys) at the PVA microbubble surface. Hence, we show the suitability of PVA MBs as selective Y-microdevices for in situ injection via the smallest (i.e., 1.2F) neurointerventional microcatheter available on the market and the accumulation of PVA MBs on the HUVEC cell line model of integrin overexpression, thereby providing ~6 × 10−15 moles of Y90 per HUVEC cell. We further discuss the potential impact of using such versatile PVA MBs as a new therapeutic chance for treating glioblastoma multiforme recurrence.

18 November 2022 in Cancers
Verified
Journal Article
Open access
PDF file
SMSusanna Mattoni
Susanna Mattoni
AFAndrea Farolfi
Andrea Farolfi
FFFabio Formaggio
Fabio Formaggio
GBGabriel Bruno
Gabriel Bruno
PCPaola Caroli
Paola Caroli
Stefano FantiStefano Fanti
Stefano Fanti
Background: To evaluate the diagnostic performance of PSMA-PET compared to conventional imaging/liver biopsy in the detection of liver metastases in CRPC patients. Moreover, we evaluated a PSMA-PET/CT-based radiomic model able to identify liver metastases. Methods: Multicenter retrospective study enrolling patients with the following inclusion criteria: (a) proven CRPC patients, (b) PSMA-PET and conventional imaging/liver biopsy performed in a 6 months timeframe, (c) no therapy changes between PSMA-PET and conventional imaging/liver biopsy. PSMA-PET sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for liver metastases were calculated. After the extraction of radiomic features, a prediction model for liver metastases identification was developed. Results: Sixty CRPC patients were enrolled. Within 6 months before or after PSMA-PET, conventional imaging and liver biopsy identified 24/60 (40%) patients with liver metastases. PSMA-PET sensitivity, specificity, PPV, NPV, and accuracy for liver metastases were 0.58, 0.92, 0.82, 0.77, and 0.78, respectively. Either number of liver metastases and the maximum lesion diameter were significantly associated with the presence of a positive PSMA-PET (p < 0.05). On multivariate regression analysis, the radiomic feature-based model combining sphericity, and the moment of inverse difference (Idm), had an AUC of 0.807 (95% CI:0.686-0.920). Conclusion: For liver metastases assessment, [68Ga]Ga-PSMA-11-PET demonstrated moderate sensitivity while high specificity, PPV, and inter-reader agreement compared to conventional imaging/liver biopsy in CRPC patients.

30 March 2023 in Medical Physics
Verified
Journal Article
Open access
FZFederico Zagni
Federico Zagni
SVSara Vichi
Sara Vichi
GPGiulia Paolani
Giulia Paolani
MSMiriam Santoro
Miriam Santoro
GGGiuseppe Della Gala
Giuseppe Della Gala
LSLidia Strigari
Lidia Strigari
Background: High‐dose rate brachytherapy using a non‐sealed 188Rhenium resin (188Re) is a recently approved treatment option for non‐melanoma skin cancer (NMSC). The treatment goal is to deliver a personalized absorbed dose to the deepest point of neoplastic infiltration corresponding to the minimal target dose. The treatment consists of the application of a 188Re‐based resin over a plastic foil placed on the target skin surface. However, there is no treatment planning tool to assess the 188Re activity needed for a personalized treatment.Purpose: The paper aims to present a novel Monte Carlo (MC)‐based tool for 188Re‐based resin activity and dose calculation, experimentally validated using Gafchromic EBT3 films.Methods: MC simulations were carried out using FLUKA modeling density and composition of 188Re resin. The MC‐based look up table (LUT) was incorporated in an ad hoc developed tool. The proposed tool allows the personalized calculation of treatment parameters (i.e., activity to be dispensed, the treatment duration, and dose volume histograms), according to the target dimension. The proposed tool was compared using Bland–Altman analysis to the previous calculation approaches conducted using VARSKIN in a retrospective cohort of 76 patients. The tool was validated in ad hoc experimental set ups using a stack of calibrated Gafchromic EBT3 films covered by a plastic film and exposed using a homogenous activity distribution of 188Re eluate and a heterogeneous activity distribution of 188Re resin mimic the patient treatment.Results: The agreement between the proposed tool and VARSKIN was evaluated on the investigated cohort with median range of target area, target depth, and treatment time equal to 4.8 [1.0–60.1] cm2, 1.1 [0.2–3.0] mm, and 70 [21–285] min, with a median range of target dose (Gy) of 23.5 [10–54.9]. The calculated minimal target doses, ranged from 1% to 10% for intermediate target depths (1.2 ± 0.7 mm), while showing significant differences in the estimation of superficial (maximal) target doses. The agreement between MC calculation and measurements at different plans in a stack of Gafchromic EBT3 films was within 10% for both the homogenous and heterogeneous activity distribution of 188Re. Worst agreements were observed for absorbed doses lower than 0.3 Gy.Conclusions: Our results support the implementation of our MC‐based tool in the practical routine for calculating the 188Re resin activity and treatment parameters necessary for obtaining the prescribed minimal target dose.