Viet Dao

Mr. Viet Dao


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
VDViet Dao
Viet Dao
EMEkaterina Mikhaylova
Ekaterina Mikhaylova
MAMax Ludwig Ahnen
Max Ludwig Ahnen
JFJannis Fischer
Jannis Fischer
KTKris Thielemans
Kris Thielemans
CTCharalampos Tsoumpas
Charalampos Tsoumpas
Software for Tomographic Image Reconstruction (STIR) is an open source C++ library used to reconstruct single photon emission tomography and positron emission tomography (PET) data. STIR has an experimental scanner geometry modelling feature to accurately model detector placement. In this study, we test and improve this new feature using several types of data: Monte Carlo simulations and measured phantom data acquired from a dedicated brain PET prototype scanner. The results show that the new geometry class applied to non-cylindrical PET scanners improved spatial resolution, uniformity, and image contrast. These are directly observed in the reconstructions of small features in the test quality phantom. Overall, we conclude that the revised “BlocksOnCylindrical” class will be a valuable addition to the next STIR software release with adjustments of existing features (Single Scatter Simulation, forward projection, attenuation corrections) to “BlocksOnCylindrical”.

30 July 2025 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
ZLZekai Li
Zekai Li
PMPhilipp Mohr
Philipp Mohr
VDViet Dao
Viet Dao
GLGert Luurtsema
Gert Luurtsema
ABAdrienne Brouwers
Adrienne Brouwers
CTCharalampos Tsoumpas
Charalampos Tsoumpas
Simultaneous dual-tracer positron emission tomography (PET) allows for the measurement of two distinct physiological processes within a single scan, i.e. under identical biological conditions. Quantification of 89Zr-labeled monoclonal antibody (89ZrmAb) uptake can be influenced by perfusion. Perfusion can be measured using 15.OH2O PET, but considerable variability in perfusion between scans may be an issue, there is a need to measure it at the same time as 89ZrmAb uptake. Based on the high sensitivity of long axial field-of-view (LAFOV) PET, this simulation study uses digital twins based on real patient scans to evaluate the feasibility of 15OH2O and 89ZrmAb dual-tracer imaging. Using a 15-minute scanning protocol, kinetic-based and subtraction-based methods were employed to recover 15OH2O kinetic parameters (K1 and VT) at both volume-of-interest (VOI) and voxel levels for various tracer uptake scenarios. Quantitative assessment was carried out using scatter and Bland-Altman plots by comparing 15OH2O parameters derived from a dual-tracer scan with those derived from the corresponding single tracer 15OH2O results. Both methods showed excellent recovery of 15OH2O kinetic parameters, with correlation coefficients exceeding 0.99 for VOI-level estimates and 0.94 for voxel-level estimates. Performance was further validated through bias versus standard deviation analyses. This study demonstrates the feasibility of a clinically practical 15-minute protocol for a simultaneous 15OH2O and 89ZrmAb PET acquisition while retaining accuracy of 15OH2O quantification.