Jamal Mehralipour

Dr. Jamal Mehralipour


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
ATAli Toolabi
Ali Toolabi
MTMahsa Tahergorabi
Mahsa Tahergorabi
JMJamal Mehralipour
Jamal Mehralipour
NSNeda Seyedi
Neda Seyedi
NNNegin Nasseh
Negin Nasseh
Ternary g-C3N4/CQD/Ag photocatalysts were synthesized via deposition of carbon quantum dots (CQDs) and silver nanoparticles (Ag) onto graphitic carbon nitride (g-C3N4) for efficient acetaminophen degradation. The nanocomposites exhibited enhanced photoresponse and broad-spectrum photocatalytic activity under both UV (254 nm, 250 W) and Xenon (>420 nm, 500 W) irradiation. Characterization by XRD, FTIR, SEM, PL, and EDX elucidated the material’s composition, structure, morphology, and optical properties. Optimized photocatalytic degradation of acetaminophen (50 mg/L) was achieved at pH 7 with 0.6 g/L catalyst loading and 60 min irradiation, yielding degradation efficiencies of 87.5% (UV) and 85.3% (Xenon). Radical quenching experiments and GC-MS analysis identified hydroxyl radicals as the primary reactive species and revealed a gradual decrease in intermediate toxicity during mineralization. This study demonstrates the superior photocatalytic performance of the ternary g-C3N4/CQD/Ag nanocomposites compared to binary systems for effective acetaminophen removal.

18 February 2020 in International Journal of Environmental Analytical Chemistry
Verified
Journal Article
Closed access
MBMojtaba Yegane Badi
Mojtaba Yegane Badi
MVMehdi Vosoughi
Mehdi Vosoughi
HSHadi Sadeghi
Hadi Sadeghi
SMS.Ahmad Mokhtari
S.Ahmad Mokhtari
JMJamal Mehralipour
Jamal Mehralipour
This experimental study investigated the performance of Catechol degradation by US/TiO2/H2O2 process as an integrated advance oxidation process. In this experimental study, initial pH, dose of TiO2, initial concentration of Catechol, H2O2 concentration and reaction time parameters optimised BBD. The results suggest that US/TiO2/H2O2 process has a high efficiency in Catechol degradation. Optimum condition of US/TiO2/H2O2 process is pH = 3.43, H2O2 concentration = 130 mg/l, TiO2 dose = 0.34 g/l, Catechol concentration = 12.52 mg/l and reaction time = 70.64 min. According to predicate point, the percentage of Catechol removal in this condition was 96.2 and 92.34 as a predicated and experimental percentage of Catechol removal by this process. The kinetics of reaction follows pseudo-first-order kinetic. The synergist effect of sonolysis, TiO2 and H2O2 is 2.09 fold. 70 and 63% of initial COD and TOC were removed. Presence of radical scavenger has an adverse impact on the performance of US/TiO2/H2O2 process.

20 September 2021 in International Journal of Environmental Analytical Chemistry
Verified
Journal Article
Closed access
SKSanaz Khoramipour
Sanaz Khoramipour
JMJamal Mehralipour
Jamal Mehralipour
MHMohadesh Hosseini
Mohadesh Hosseini
Landfilling in many countries is the most embraced method for disposal of municipal, agricultural and industrial waste. However, the main issue imposed for landfilling is the landfill leachate (LL) leakage. Leachate with high pollution is threating the soil and water resources. Leachate treatment is known as a challenging and issues due to inherent liable and refractory composition. A hybrid processes sono-electrocoagulation is an efficient and applicable method for LL treatment. In the present study, response surface methodology (RSM) and central composite design (CCD) approach were employed to optimise the important influencing factors (pH, reaction time, direct electrical current) in Sono-electrocoagulation for LL treatment. The results obtained from the present study indicated that the optimum condition is pH = 6 for efficient COD removal. An important quadratic regression model was taken to fit the laboratory data; the influencing factors were statistically significant. The purposed model was considered for the response in permitted error. The fit precision ratio was achieved as 54.36. The COD removal in optimised conditions (pH: 5.7, reaction time: 80 min, direct current: 1.9 A) was found to be 86%. The kinetics of reaction (R2 = 0.98) followed from first-order kinetic. Electrocoagulation process (45%) and sonolysis mechanism (12%) have a lower performance in COD removal individually. However, the combined Sono-electrocoagulation showed a synergist effect and increased the COD removal in leachate (SF = 1.5). In the optimum condition, the operational cost of the sono-electrocoagulation process is 6.28 US $/m3. The changes in the sludge the during process indicate the changes in the microscopic structure and elements in the sludge produced after the process.

22 January 2021 in Journal of Environmental Health Science and Engineering
Verified
Journal Article
Open access
PDF file
Majid KermaniMajid Kermani
Majid Kermani
ASAbbas Shahsavani
Abbas Shahsavani
PGPegah Ghaderi
Pegah Ghaderi
PKPooria Kasaee
Pooria Kasaee
JMJamal Mehralipour
Jamal Mehralipour
With increased population, treatment of solid waste landfill and its leachate is of major concern. Municipal landfill leachate shows variable, heterogeneous and incontrollable characteristics and contains wide range highly concentrated organic and inorganic compounds, in which hampers the application of a solo method in its treatment. Among different approaches, biological treatment can be used, however it is not effective enough to elimination all refractory organics, containing fulvic-like and humic-like substance. In this experimental study, the UV Electroperoxone process as a hybrid procedure has been employed to treat landfill leachate. The effect of various parameters such as pH, electrical current density, ozone concentration, and reaction time were optimized using central composite design (CCD). In the model fitting, the quadratic model with a P-Value less than 0.5 was suggested (< 0.0001). The R2, R2 adj, and R2 pre were determined equal to 0.98,0.96, and 0.91 respectively. Based on the software prediction, the process can remove 83% of initial COD, in the optimum condition of pH = 5.6, ozone concentration of 29.1 mg/l. min, the current density of 74.7 mA/cm2, and process time of 98.6 min. In the optimum condition, 55/33 mM H2O2 was generated through electrochemical mechanism. A combination of ozonation, photolysis and electrolysis mechanism in this hybrid process increases COD efficiency removal up 29 percent which is higher than the sum of separated mechanisms. Kinetic study also demonstrated that the UV-EPP process follows pseudo-first order kinetics (R2 = 0.99). Based on our results, the UV-EPP process can be informed as an operative technique for treatment of old landfills leachates. Graphical abstract

5 August 2025 in Chemical Engineering Science
Verified
Journal Article
Closed access
EAElham Abbasnejad Ara
Elham Abbasnejad Ara
AJAhmad Jonidi Jafari
Ahmad Jonidi Jafari
Majid KermaniMajid Kermani
Majid Kermani
JMJamal Mehralipour
Jamal Mehralipour
AEAli Esrafili
Ali Esrafili

2 June 2024 in Journal of Advances in Environmental Health Research
Verified
Journal Article
Open access
PDF file
RMRoya Mafigholami
Roya Mafigholami
JMJamal Mehralipour
Jamal Mehralipour
MHMona Hosseini
Mona Hosseini
MJMajid Jahanshiri
Majid Jahanshiri
Background: Water contamination by synthetic organic chemicals like antibiotics is a major environmental issue. Tetracycline (TC), an antibiotic in a wide family, is notable. A moving bed sequenced batch reactor (MBSBR) is tested for treating hospital raw wastewater containing TC. Methods: A 35-L pilot system was constructed, with 30 L usable. PVC suspended carriers (Kaldnes K3) with 584.3 m2 /m3 specific surface area made about 70% of the functional volume. The independent variables in this study were hydraulic retention duration (1, 1.5, 2, and 2.5 hours) and starting TC concentration (5, 10, and 15 mg/L). Results: The findings of the study demonstrated satisfactory performance under the conditions of an initial TC concentration of 5 mg/L and an organic load of 350 mg/L. The overall removal efficiencies for TC, chemical oxygen demand (COD), and biological oxygen demand (BOD5 ) were 72.8%, 83%, and 93.9%, respectively. The optimal performance of the system was primarily observed during the initial phase, characterized by a TC concentration of 5 mg/L and a hydraulic retention time (HRT) of 2.5 hours. The experimental results also indicated that the maximum removal efficiency was 1.8 kg COD/m2 .day, as determined by a fitted surface loading rate (SLR). Furthermore, the food-tomicroorganism (F/M) ratio decreased from 0.101 to 0.038 as the HRT increased from 1 to 2.5 hours. Conclusion: The results of the study indicate that the MBSBR exhibits a high level of efficiency in removing TC from hospital wastewater.