In-Su Bae

Prof. In-Su Bae

Kangwon National University
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2024 in Energies
Verified
Journal Article
Open access
PDF file
YSYeong Geon Son
Yeong Geon Son
SKSung-Yul Kim
Sung-Yul Kim
In-Su BaeIn-Su Bae
In-Su Bae
To advance carbon neutrality policies, many countries are increasingly integrating Renewable Energy Sources (RESs) into their energy mix. However, for harnessing natural energy in power generation, RESs present challenges in output control, potentially leading to power imbalances. Such imbalances, when coupled with an excessive reliance on unpredictable RES, may necessitate the curtailment of grid-integrated renewable generation, halting production despite available capacity. This paper proposes strategies to mitigate the economic and operational efficiency impacts of increased RESs on the power grid. It focuses on the optimal operation of Battery Energy Storage Systems (BESSs) and Power to Gas (P2G) technology, which flexibly converts surplus electricity into hydrogen. By employing Mixed Integer Linear Programming (MILP) for optimization and Stochastic Programming (SP) for the management of the uncertainty of renewable energy output, this paper evaluates the anticipated benefits of BESS and P2G applications.

23 November 2023 in IEEE Access
Verified
Journal Article
Open access
In-Su BaeIn-Su Bae
In-Su Bae
ESEun-Tae Son
Eun-Tae Son
SKSung-Yul Kim
Sung-Yul Kim
Dong-Min KimDong-Min Kim
Dong-Min Kim
This study proposes a method for optimizing the cable sizes in the collection systems of wind turbines on offshore wind farms. Although cable size optimizations for offshore wind farms may require a high initial investment, the power losses are considerably reduced over the system lifespan, thereby justifying the high investment. The proposed method employs a simple binary integer programming model that can determine optimum cable sizes and related cable costs (installation and loss costs) with minimal inputs regarding the topology of the wind-turbine collection system. It can be employed to design the electrical infrastructure of offshore wind farms using heuristic or metaheuristic approaches, as it can automatically calculate the power flows in arcs using bus injection to branch current matrices, even if the system topology changes. Furthermore, we have introduced a method of calculating the power losses by accounting for the diverse capacities and availabilities of WTs to reflect the actual characteristics of WTs. Our method was validated at two offshore wind-farm sites in the Southwestern Sea of Korea, one 60 MW and the other 400 MW, and this study provides some simple examples and the related parameters. Owing to the optimal cable size, the proposed technique (combined with K-clustering based genetic algorithm) demonstrated cost savings in the range of 1.55%-2.21% within the wind-turbine collection system when compared with the conventional metaheuristic methods. Moreover, the cost-based topology modifications achieved cost savings in the range of 0.18%-0.66%.

15 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
ESEun-Tae Son
Eun-Tae Son
In-Su BaeIn-Su Bae
In-Su Bae
SKSung-Yul Kim
Sung-Yul Kim
Dong-Min KimDong-Min Kim
Dong-Min Kim
Recently, it has been suggested that microgrids (MGs) can improve the resilience of distribution systems. However, predictions about future faults are uncertain. This makes calculating the exact value of the benefits of system resilience enhancement close to impossible at the time of MG planning. Therefore, this paper proposes a framework for MG planning, which focuses on resilience estimation. To consider the uncertainties of future failure events, the proposed method for estimating the resilience utilized the Monte Carlo simulation. In addition, an optimal scenario was estimated using a cost–benefit analysis and constraints on the expected value of resilience enhancement. In the case study, an actual MG installation at D-university was evaluated to obtain the optimal MG planning scenario. The results show that the capacity and installation locations of the distributed generators (DGs) impact the resilience enhancement. The proposed method can effectively derive the optimal MG planning scenario by evaluating the possibility of future operations based on the segmentation of both the system configuration and type of DG to improve the resilience of distribution systems.

6 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
In-Su BaeIn-Su Bae
In-Su Bae
SKSung-Yul Kim
Sung-Yul Kim
Dong-Min KimDong-Min Kim
Dong-Min Kim
When a meteorological disaster occurs and equipment becomes damaged, a significant amount of time is required to repair the damaged components as it is impossible to repair several components simultaneously. Therefore, the determination of repair priority is a significant aspect of a distribution system’s resilience. This study proposes a technique to identify the unserved areas of a radial distribution system based on the bus injection to the branch current (BIBC) matrix, as opposed to a complex optimization technique, for evaluating the repair priority determination strategy for all the possible disaster scenarios. Generally, most resilience metrics include the concept of duration; therefore, the strategy for resilience enhancement must optimize the recovery priority using an objective function that consists of the recovered capacity increment, rather than the recovered capacity. To verify the proposed method, in this paper, the resilience is evaluated under all the disaster scenarios that can occur in contingencies from N-2 to N-5. Since complex restoration or repair strategies could be simplified using the proposed method, it is expected that this study will make a significant contribution to the resilience enhancement in distribution systems.

12 April 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ESEun-Tae Son
Eun-Tae Son
Dong-Min KimDong-Min Kim
Dong-Min Kim
In-Su BaeIn-Su Bae
In-Su Bae
DZDongbo Zhao
Dongbo Zhao
SKSung-Yul Kim
Sung-Yul Kim
In power system resilience, the dynamic state of a system can be assessed via the sectionalization process which is necessary to search for available and unavailable load points (ALP, ULP) in a system configuration that changes over time. To develop an automatic and quick search for ALP and ULP in a dynamic system configuration, this paper proposes an ALP searching (ALPS) method with formulation. In the case study, the accuracy and computational performance of the proposed method are analyzed based on the recovery strategies considered during the resilience assessment process. The proposed method has the ability to exactly analyze ALP and ULP in radial, loop, and mesh system configurations, which can be applied to both transmission and distribution systems. The results of this paper demonstrate that the proposed method yields an excellent performance for various system configurations and recovery strategies.

21 November 2025 in Mathematics
Verified
Journal Article
Open access
PDF file
Dong-Min KimDong-Min Kim
Dong-Min Kim
In-Su BaeIn-Su Bae
In-Su Bae
JRJae-Ho Rhee
Jae-Ho Rhee
WSWoo-Chang Song
Woo-Chang Song
SBSunghyun Bae
Sunghyun Bae
This paper presents an optimal-design methodology for small-scale Integrated Energy Systems (IESs) that couple electricity and heat in distributed networks. A hybrid reliability assessment integrates probabilistic state enumeration with scenario-based simulation. Mathematically, the design is cast as a stochastic, reliability-driven ranking: time-sequential Monte Carlo (MC) produces estimators of Loss of Load Probability (LOLP), Expected Energy Not Supplied (EENS), and Self-Sufficiency Rate (SSR), which are normalized and combined into a Composite Reliability Index (CRI) that orders candidate siting/sizing options. The case study is the D-campus microgrid with Photovoltaic (PV), Combined Heat and Power (CHP), Fuel Cell (FC), Battery Energy Storage Systems (BESSs), and Heat Energy Storage Systems (HESSs; also termed TESs), across multiple siting and sizing scenarios. Results show consistent reductions in LOLP and EENS and increases in SSR as distributed energy resource capacity increases and resources are placed near critical nodes, with the strongest gains observed in the best-performing configurations. The CRI also reveals trade-offs across intermediate scenarios. The operational concept of the campus Energy Management System (EMS), including full operating modes and scheduling logic, is developed to maintain a design focus on reliability-driven decision making. Probability-based formulations, reliability metrics, and the sequential MC setup underpin the proposed ranking framework. The proposed method supports Distributed Energy Resource (DER) sizing and siting decisions for reliable, autonomy-oriented IESs.