Jae-Ho Rhee

Prof. Dr. Jae-Ho Rhee


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2023 in Energies
Verified
Journal Article
Open access
PDF file
HLhyun seung Lee
hyun seung Lee
HKHyung-Wook Kang
Hyung-Wook Kang
JRJae-Ho Rhee
Jae-Ho Rhee
KLKun-a Lee
Kun-a Lee
Hybrid circuit breakers are the most promising circuit breakers among DC circuit breakers. Conventional hybrid circuit breakers complete fault current isolation by converting current to IGBT when fault current occurs. However, in this case, the fault current continues to increase, so the IGBT must be large enough to withstand this current. In addition, in the case of a method of detecting and operating a fault, a delay time of up to hundreds of microseconds occurs, and in a hybrid circuit breaker, this delay time is a very large value. To solve this problem, this paper proposes a hybrid Z-source circuit breaker that operates without delay for low-impedance faults. The proposed breaker is designed to reduce stress on IGBTs and mechanical switches by generating a current zero crossing, as well as to enable the breaker to trip quickly in high-risk cases such as low-impedance fault circuits. Due to the limited environment of the laboratory, we performed 600 V fault isolation experiments. As a result of the experiment, it was confirmed that the proposed circuit breaker successfully isolated the fault within 1.6 ms. The current limiting feature of the Z-source appears to reduce stress on the IGBTs and MOVs used, and it allows for faster fault isolation.

24 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
HLhyun seung Lee
hyun seung Lee
YCYoung-Maan Cho
Young-Maan Cho
KLKun-a Lee
Kun-a Lee
JRJae-Ho Rhee
Jae-Ho Rhee
In this paper, a new design is provided so that the Z-source circuit breaker with a mechanical switch operates quickly at a low-impedance fault. When the fault occurs, the Z-source circuit breaker uses an impedance network to generate forced current zero crossing on the switch. This current zero-crossing time is not sufficient when mechanical switches are applied. In addition, since the MS switch operates through the fault detection sensor, the speed is slowed down. At a slower speed, the circuit breaker may not allow fault current isolation. To solve this problem, the Thomson coil was added to the circuit. It operates immediately in a low-impedance fault without additional fault detection devices. As a result, the faster operating speed is expected to reduce the size of the Z-source circuit breaker component and the stress of the breaker. It is mathematically analyzed and derived, and verified through simulations and experiments. The main features of the proposed model are fast detection and operation, normal-state circuit disconnect, fault current limitation, and low conduction loss.

20 September 2023 in Energies
Verified
Journal Article
Open access
PDF file
HKHyung-Wook Kang
Hyung-Wook Kang
HLhyun seung Lee
hyun seung Lee
JRJae-Ho Rhee
Jae-Ho Rhee
KLKun-a Lee
Kun-a Lee
Studies have been conducted on Energy storage systems (ESS) that replaced lithium-ion batteries (LIB) by the thermal runaway of the existing LIB. Using only the supercapacitor (SC) as a direct current power source in applications such as supercapacitor-based ESSs and mobile electric vehicle charging stations (MCSs) reduces the output voltage of the SC linearly. To solve this problem, this paper combines a boost converter capable of achieving regulatable constant voltage from an input of an SC bank to an output of a rectifier and an inductor/capacitor/capacitor (LCC) resonance converter. In this paper, an electrical double-layer capacitor (EDLC) known as SC was constructed as 64.8-V 400-FEDLC for experimental analysis. This EDLC is a high-capacity EDLC bank using 120 EDLCs with 30 serial connections and 4 parallel connections. In addition, resonance compensation circuits are analyzed and designed using a first-order harmonic approximation method (FHA). The analysis shows that the LCC resonance compensation converter is more suitable for EDLC standalone systems as an energy storage system, for LCC resonance converter topologies combined with EDLC discharge characteristics, constant voltage discharge is designed under an efficient discharge strategy, i.e., variable load conditions after the first constant voltage discharge. Based on LCC compensation analysis, the system has an optimum frequency, which allows the system to operate at the maximum efficiency point. By combining constant voltage power characteristics, constant voltage power becomes the same as the optimal power point, and thus high efficiency could be maintained in the constant voltage stage. Finally, the above design is verified through experiments.

21 November 2025 in Mathematics
Verified
Journal Article
Open access
PDF file
Dong-Min KimDong-Min Kim
Dong-Min Kim
In-Su BaeIn-Su Bae
In-Su Bae
JRJae-Ho Rhee
Jae-Ho Rhee
WSWoo-Chang Song
Woo-Chang Song
SBSunghyun Bae
Sunghyun Bae
This paper presents an optimal-design methodology for small-scale Integrated Energy Systems (IESs) that couple electricity and heat in distributed networks. A hybrid reliability assessment integrates probabilistic state enumeration with scenario-based simulation. Mathematically, the design is cast as a stochastic, reliability-driven ranking: time-sequential Monte Carlo (MC) produces estimators of Loss of Load Probability (LOLP), Expected Energy Not Supplied (EENS), and Self-Sufficiency Rate (SSR), which are normalized and combined into a Composite Reliability Index (CRI) that orders candidate siting/sizing options. The case study is the D-campus microgrid with Photovoltaic (PV), Combined Heat and Power (CHP), Fuel Cell (FC), Battery Energy Storage Systems (BESSs), and Heat Energy Storage Systems (HESSs; also termed TESs), across multiple siting and sizing scenarios. Results show consistent reductions in LOLP and EENS and increases in SSR as distributed energy resource capacity increases and resources are placed near critical nodes, with the strongest gains observed in the best-performing configurations. The CRI also reveals trade-offs across intermediate scenarios. The operational concept of the campus Energy Management System (EMS), including full operating modes and scheduling logic, is developed to maintain a design focus on reliability-driven decision making. Probability-based formulations, reliability metrics, and the sequential MC setup underpin the proposed ranking framework. The proposed method supports Distributed Energy Resource (DER) sizing and siting decisions for reliable, autonomy-oriented IESs.