Angelos Karatsidis

Dr. Angelos Karatsidis

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2016 in Sensors
Verified
Journal Article
Open access
PDF file
AKAngelos Karatsidis
Angelos Karatsidis
GBGiovanni Bellusci
Giovanni Bellusci
MSMartin Schepers
Martin Schepers
Mark de ZeeMark de Zee
Mark de Zee
Michael AndersenMichael Andersen
Michael Andersen
PVPeter Veltink
Peter Veltink
Ground reaction forces and moments (GRF&M) are important measures used as input in biomechanical analysis to estimate joint kinetics, which often are used to infer information for many musculoskeletal diseases. Their assessment is conventionally achieved using laboratory-based equipment that cannot be applied in daily life monitoring. In this study, we propose a method to predict GRF&M during walking, using exclusively kinematic information from fully-ambulatory inertial motion capture (IMC). From the equations of motion, we derive the total external forces and moments. Then, we solve the indeterminacy problem during double stance using a distribution algorithm based on a smooth transition assumption. The agreement between the IMC-predicted and reference GRF&M was categorized over normal walking speed as excellent for the vertical (ρ = 0.992, rRMSE = 5.3%), anterior (ρ = 0.965, rRMSE = 9.4%) and sagittal (ρ = 0.933, rRMSE = 12.4%) GRF&M components and as strong for the lateral (ρ = 0.862, rRMSE = 13.1%), frontal (ρ = 0.710, rRMSE = 29.6%), and transverse GRF&M (ρ = 0.826, rRMSE = 18.2%). Sensitivity analysis was performed on the effect of the cut-off frequency used in the filtering of the input kinematics, as well as the threshold velocities for the gait event detection algorithm. This study was the first to use only inertial motion capture to estimate 3D GRF&M during gait, providing comparable accuracy with optical motion capture prediction. This approach enables applications that require estimation of the kinetics during walking outside the gait laboratory.

5 February 2019 in Medical Engineering & Physics
Verified
Journal Article
Open access
AKAngelos Karatsidis
Angelos Karatsidis
MJMoonki Jung
Moonki Jung
HSH. Martin Schepers
H. Martin Schepers
GBGiovanni Bellusci
Giovanni Bellusci
Mark de ZeeMark de Zee
Mark de Zee
MAMichael Skipper Andersen
Michael Skipper Andersen
Inverse dynamic analysis using musculoskeletal modeling is a powerful tool, which is utilized in a range of applications to estimate forces in ligaments, muscles, and joints, non-invasively. To date, the conventional input used in this analysis is derived from optical motion capture (OMC) and force plate (FP) systems, which restrict the application of musculoskeletal models to gait laboratories. To address this problem, we propose the use of inertial motion capture to perform musculoskeletal model-based inverse dynamics by utilizing a universally applicable ground reaction force and moment (GRF&M) prediction method. Validation against a conventional laboratory-based method showed excellent Pearson correlations for sagittal plane joint angles of ankle, knee, and hip (ρ=0.95, 0.99, and 0.99, respectively) and root-mean-squared-differences (RMSD) of 4.1 ± 1.3°, 4.4 ± 2.0°, and 5.7 ± 2.1°, respectively. The GRF&M predicted using IMC input were found to have excellent correlations for three components (vertical: ρ=0.97, RMSD = 9.3 ± 3.0 %BW, anteroposterior: ρ=0.91, RMSD = 5.5 ± 1.2 %BW, sagittal: ρ=0.91, RMSD = 1.6 ± 0.6 %BW*BH), and strong correlations for mediolateral (ρ=0.80, RMSD = 2.1 ± 0.6 %BW) and transverse (ρ=0.82, RMSD = 0.2 ± 0.1 %BW*BH). The proposed IMC-based method removes the complexity and space restrictions of OMC and FP systems and could enable applications of musculoskeletal models in either monitoring patients during their daily lives or in wider clinical practice.

9 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
JKJason Konrath
Jason Konrath
AKAngelos Karatsidis
Angelos Karatsidis
HSH. Martin Schepers
H. Martin Schepers
GBGiovanni Bellusci
Giovanni Bellusci
Mark de ZeeMark de Zee
Mark de Zee
Michael AndersenMichael Andersen
Michael Andersen
Knee osteoarthritis is a major cause of pain and disability in the elderly population with many daily living activities being difficult to perform as a result of this disease. The present study aimed to estimate the knee adduction moment and tibiofemoral joint contact force during daily living activities using a musculoskeletal model with inertial motion capture derived kinematics in an elderly population. Eight elderly participants were instrumented with 17 inertial measurement units, as well as 53 opto-reflective markers affixed to anatomical landmarks. Participants performed stair ascent, stair descent, and sit-to-stand movements while both motion capture methods were synchronously recorded. A musculoskeletal model containing 39 degrees-of-freedom was used to estimate the knee adduction moment and tibiofemoral joint contact force. Strong to excellent Pearson correlation coefficients were found for the IMC-derived kinematics across the daily living tasks with root mean square errors (RMSE) between 3° and 7°. Furthermore, moderate to strong Pearson correlation coefficients were found in the knee adduction moment and tibiofemoral joint contact forces with RMSE between 0.006–0.014 body weight × body height and 0.4 to 1 body weights, respectively. These findings demonstrate that inertial motion capture may be used to estimate knee adduction moments and tibiofemoral contact forces with comparable accuracy to optical motion capture.

15 August 2018 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
AKAngelos Karatsidis
Angelos Karatsidis
RRRosie E. Richards
Rosie E. Richards
JKJason Konrath
Jason Konrath
JNJosien C. van Den Noort
Josien C. van Den Noort
MSMartin Schepers
Martin Schepers
PVPeter Veltink
Peter Veltink
Gait retraining interventions using real-time biofeedback have been proposed to alter the loading across the knee joint in patients with knee osteoarthritis. Despite the demonstrated benefits of these conservative treatments, their clinical adoption is currently obstructed by the high complexity, spatial demands, and cost of optical motion capture systems. In this study we propose and evaluate a wearable visual feedback system for gait retraining of the foot progression angle (FPA). The primary components of the system are inertial measurement units, which track the human movement without spatial limitations, and an augmented reality headset used to project the visual feedback in the visual field. The adapted gait protocol contained five different target angles ranging from 15 degrees toe-out to 5 degrees toe-in. Eleven healthy participants walked on an instrumented treadmill, and the protocol was performed using both an established laboratory visual feedback driven by optical motion capture, and the proposed wearable system. The wearable system tracked FPA with an accuracy of 2.4 degrees RMS and ICC=0.94 across all target angles and subjects, when compared to an optical motion capture reference. In addition, the effectiveness of the biofeedback, reflected by the number of steps with FPA value ±2 degrees from the target, was found to be around 50% in both wearable and laboratory approaches. These findings demonstrate that retraining of the FPA using wearable inertial sensing and visual feedback is feasible with effectiveness matching closely an established laboratory method. The proposed wearable setup may reduce the complexity of gait retraining applications and facilitate their transfer to routine clinical practice.

18 February 2025 in Multiple Sclerosis Journal
Verified
Journal Article
Open access
AKAngelos Karatsidis
Angelos Karatsidis
LALorenza Angelini
Lorenza Angelini
MSMatthew Scaramozza
Matthew Scaramozza
EBEmmanuel Bartholome
Emmanuel Bartholome
SCSusanne P Clinch
Susanne P Clinch
LCLicinio Craveiro
Licinio Craveiro
Background: Mobility assessment is essential for monitoring disease progression in people with multiple sclerosis (PwMS). Technologies such as wearable sensors show potential for this purpose, but consensus is needed to optimize collection and interpretation of digital measures in PwMS. Objective: To propose a framework for measuring and interpreting key aspects of impaired gait in PwMS using a smartphone worn at the waist level. Methods: The framework was developed on the basis of clinical understanding and knowledge of sensor signal processing, supported by a systematic literature review (SLR). The SLR targeted articles published after 2011 that measured gait characteristics in PwMS. Findings were used to propose standardized definitions for complementary gait domains and define digital measures that should be captured for each domain. Results: The resulting framework for PwMS recommends definitions for pace, rhythm, stability, symmetry, variability, smoothness, complexity and fatigability gait domains. For each domain, a set of digital measures is described with respect to their interpretability and associated caveats. Conclusion: This framework provides recommendations for measuring complex gait patterns in PwMS using widely available technology. This work promotes the use of standardized gait domain definitions and harmonized descriptions of associated digital measures, paving the way for future validation efforts.

5 January 2018 in arXiv
Verified
Preprint
Open access
PDF file
AKAngelos Karatsidis
Angelos Karatsidis
MJMoonki Jung
Moonki Jung
HSH. Martin Schepers
H. Martin Schepers
GBGiovanni Bellusci
Giovanni Bellusci
MZMark de Zee
Mark de Zee
MAMichael Skipper Andersen
Michael Skipper Andersen
Inverse dynamic analysis using musculoskeletal modeling is a powerful tool, which is utilized in a range of applications to estimate forces in ligaments, muscles, and joints, non-invasively. To date, the conventional input used in this analysis is derived from optical motion capture (OMC) and force plate (FP) systems, which restrict the application of musculoskeletal models to gait laboratories. To address this problem, we propose a musculoskeletal model, capable of estimating the internal forces based solely on inertial motion capture (IMC) input and a ground reaction force and moment (GRF&M) prediction method. We validated the joint angle and kinetic estimates of the lower limbs against an equally constructed musculoskeletal model driven by OMC and FP system. The sagittal plane joint angles of ankle, knee, and hip presented excellent Pearson correlations (\rho = 0.95, 0.99, and 0.99, respectively) and root-mean-squared differences (RMSD) of 4.1 $\pm$ 1.3$\circ$, 4.4 $\pm$ 2.0$\circ$, and 5.7 $\pm$ 2.1$\circ$, respectively. The GRF&M predicted using IMC input were found to have excellent correlations for three components (vertical:\rho = 0.97, RMSD=9.3 $\pm$ 3.0 %BW, anteroposterior: \rho = 0.91, RMSD=5.5 $\pm$ 1.2 %BW, sagittal: \rho = 0.91, RMSD=1.6 $\pm$ 0.6 %BW*BH), and strong correlations for mediolateral (\rho = 0.80, RMSD=2.1 $\pm$ 0.6%BW ) and transverse (\rho = 0.82, RMSD=0.2 $\pm$ 0.1 %BW*BH). The proposed IMC-based method removes the complexity and space-restrictions of OMC and FP systems and could enable applications of musculoskeletal models in either monitoring patients during their daily lives or in wider clinical practice.