Michael Andersen

Dr. Michael Andersen

Department of Materials and Production, Aalborg Universitet, 9220 Aalborg, Denmark
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2016 in Sensors
Verified
Journal Article
Open access
PDF file
AKAngelos Karatsidis
Angelos Karatsidis
GBGiovanni Bellusci
Giovanni Bellusci
MSMartin Schepers
Martin Schepers
Mark de ZeeMark de Zee
Mark de Zee
Michael AndersenMichael Andersen
Michael Andersen
PVPeter Veltink
Peter Veltink
Ground reaction forces and moments (GRF&M) are important measures used as input in biomechanical analysis to estimate joint kinetics, which often are used to infer information for many musculoskeletal diseases. Their assessment is conventionally achieved using laboratory-based equipment that cannot be applied in daily life monitoring. In this study, we propose a method to predict GRF&M during walking, using exclusively kinematic information from fully-ambulatory inertial motion capture (IMC). From the equations of motion, we derive the total external forces and moments. Then, we solve the indeterminacy problem during double stance using a distribution algorithm based on a smooth transition assumption. The agreement between the IMC-predicted and reference GRF&M was categorized over normal walking speed as excellent for the vertical (ρ = 0.992, rRMSE = 5.3%), anterior (ρ = 0.965, rRMSE = 9.4%) and sagittal (ρ = 0.933, rRMSE = 12.4%) GRF&M components and as strong for the lateral (ρ = 0.862, rRMSE = 13.1%), frontal (ρ = 0.710, rRMSE = 29.6%), and transverse GRF&M (ρ = 0.826, rRMSE = 18.2%). Sensitivity analysis was performed on the effect of the cut-off frequency used in the filtering of the input kinematics, as well as the threshold velocities for the gait event detection algorithm. This study was the first to use only inertial motion capture to estimate 3D GRF&M during gait, providing comparable accuracy with optical motion capture prediction. This approach enables applications that require estimation of the kinetics during walking outside the gait laboratory.

1 February 2015 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
MMMarco A. Marra
Marco A. Marra
VVValentine Vanheule
Valentine Vanheule
RFRene Fluit
Rene Fluit
BKBart H. F. J. M. Koopman
Bart H. F. J. M. Koopman
John RasmussenJohn Rasmussen
John Rasmussen
Michael AndersenMichael Andersen
Michael Andersen
Musculoskeletal (MS) models should be able to integrate patient-specific MS architecture and undergo thorough validation prior to their introduction into clinical practice. We present a methodology to develop subject-specific models able to simultaneously predict muscle, ligament, and knee joint contact forces along with secondary knee kinematics. The MS architecture of a generic cadaver-based model was scaled using an advanced morphing technique to the subject-specific morphology of a patient implanted with an instrumented total knee arthroplasty (TKA) available in the fifth “grand challenge competition to predict in vivo knee loads” dataset. We implemented two separate knee models, one employing traditional hinge constraints, which was solved using an inverse dynamics technique, and another one using an 11-degree-of-freedom (DOF) representation of the tibiofemoral (TF) and patellofemoral (PF) joints, which was solved using a combined inverse dynamic and quasi-static analysis, called force-dependent kinematics (FDK). TF joint forces for one gait and one right-turn trial and secondary knee kinematics for one unloaded leg-swing trial were predicted and evaluated using experimental data available in the grand challenge dataset. Total compressive TF contact forces were predicted by both hinge and FDK knee models with a root-mean-square error (RMSE) and a coefficient of determination (R2) smaller than 0.3 body weight (BW) and equal to 0.9 in the gait trial simulation and smaller than 0.4 BW and larger than 0.8 in the right-turn trial simulation, respectively. Total, medial, and lateral TF joint contact force predictions were highly similar, regardless of the type of knee model used. Medial (respectively lateral) TF forces were over- (respectively, under-) predicted with a magnitude error of M < 0.2 (respectively > −0.4) in the gait trial, and under- (respectively, over-) predicted with a magnitude error of M > −0.4 (respectively < 0.3) in the right-turn trial. Secondary knee kinematics from the unloaded leg-swing trial were overall better approximated using the FDK model (average Sprague and Geers' combined error C = 0.06) than when using a hinged knee model (C = 0.34). The proposed modeling approach allows detailed subject-specific scaling and personalization and does not contain any nonphysiological parameters. This modeling framework has potential applications in aiding the clinical decision-making in orthopedics procedures and as a tool for virtual implant design.

1 July 2014 in Journal of Biomechanics
Verified
Journal Article
Closed access
RFR. Fluit
R. Fluit
Michael AndersenMichael Andersen
Michael Andersen
SKS. Kolk
S. Kolk
NVN. Verdonschot
N. Verdonschot
HKH.F.J.M. Koopman
H.F.J.M. Koopman

1 April 2010 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
Michael AndersenMichael Andersen
Michael Andersen
MDM. Damsgaard
M. Damsgaard
BMBruce MacWilliams
Bruce MacWilliams
John RasmussenJohn Rasmussen
John Rasmussen
This paper introduces a general optimisation-based method for identification of biomechanically relevant parameters in kinematically determinate and over-determinate systems from a given motion. The method is designed to find a set of parameters that is constant over the time frame of interest as well as the time-varying system coordinates, and it is particularly relevant for biomechanical motion analysis where the system parameters can be difficult to accurately determine by direct measurements. Although the parameter identification problem results in a large-scale optimisation problem, we show that, due to a special structure in the linearised Karush–Kuhn–Tucker optimality conditions, the solution can be found very efficiently. The method is applied to a set of test problems relevant for gait analysis. These involve determining the local coordinates of markers placed on the model, segment lengths and joint axes of rotation from both gait and range of motion experiments.

22 July 2009 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
Michael AndersenMichael Andersen
Michael Andersen
MDM. Damsgaard
M. Damsgaard
John RasmussenJohn Rasmussen
John Rasmussen
In this paper, we introduce a new general method for kinematic analysis of rigid multi body systems subject to holonomic constraints. The method extends the standard analysis of kinematically determinate rigid multi body systems to the over-determinate case. This is accomplished by introducing a constrained optimisation problem with the objective function given as a function of the set of system equations that are allowed to be violated while the remaining equations define the feasible set. We show that exact velocity and acceleration analysis can also be performed by solving linear sets of equations, originating from differentiation of the Karush–Kuhn–Tucker optimality conditions. The method is applied to the analysis of an 18 degrees-of-freedom gait model where the kinematical drivers are prescribed with data from a motion capture experiment. The results show that significant differences are obtained between applying standard kinematic analysis or minimising the least-square errors on the two fully equivalent 3D gait models with only the way the experimental data is processed being different.