Sebastian Michael Peter Tansella

Dr. Sebastian Michael Peter Tansella


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2019 in Materials
Verified
Journal Article
Open access
PDF file
Mario BerettaMario Beretta
Mario Beretta
PPPier Paolo Poli
Pier Paolo Poli
SPSilvia Pieriboni
Silvia Pieriboni
STSebastian Michael Peter Tansella
Sebastian Michael Peter Tansella
Mattia ManfrediniMattia Manfredini
Mattia Manfredini
CMCarlo Maiorana
Carlo Maiorana
Introduction: An optimal aesthetic implant restoration is a combination of a visually pleasing prosthesis and adequate surrounding peri-implant soft tissue architecture. This study describes a novel workflow for one-step formation of the supra-implant emergence profile. Materials and Methods: Two randomized groups were selected. Ten control group participants received standard healing screws at the surgical stage. Ten individualized healing abutments were Computer aided Design/Computer aided Manufacturing (CAD/CAM)-fabricated out of polyether ether ketone (PEEK) restoration material in a fully digital workflow and seated at the surgical stage in the test group. The modified healing abutment shape was extracted from a virtual library. The standard triangulation language (STL) files of a premolar and a molar were obtained considering the coronal anatomy up to the cement-enamel junction (CEJ). After a healing period ranging from 1 to 3 months depending on the location of the surgical site, namely, mandible or maxilla, a digital impression was taken. The functional implant prosthodontics score (FIPS) and the numerical rating scale (NRS) of pain were recorded and compared. Results: The mean FIPS value for the test group was 9.1 ± 0.9 while the control group mean value was 7.1 ± 0.9. In the test group, pain assessment at crown placement presented a mean value of 0.5 ± 0.7. On the contrary, the control group showed a mean value of 5.5 ± 1.6. Conclusions: Patients in the test group showed higher FIPS values and lower NRS scores during the early phases compared to the control group.

21 April 2022 in Prosthesis
Verified
Journal Article
Open access
PDF file
Mario BerettaMario Beretta
Mario Beretta
Mattia ManfrediniMattia Manfredini
Mattia Manfredini
Pier Paolo PoliPier Paolo Poli
Pier Paolo Poli
STSebastian Michael Peter Tansella
Sebastian Michael Peter Tansella
CMCarlo Maiorana
Carlo Maiorana
Implant rehabilitation is a daily practice in dentistry, and patients often have heightened expectations regarding both the functional and the aesthetic outcome. Implant–abutment connection (IAC) is involved in the long-term aesthetic quality of the rehabilitation. The use of one-piece implants for fixing dentures may prevent the mechanical and biological implication of the implant–abutment interface, resulting in a better quality of hard and soft tissue maintenance. In this case report, we present a novel one-piece implant in a maxillary rehabilitation with a full model-free digital approach.