Introduction: An optimal aesthetic implant restoration is a combination of a visually pleasing prosthesis and adequate surrounding peri-implant soft tissue architecture. This study describes a novel workflow for one-step formation of the supra-implant emergence profile. Materials and Methods: Two randomized groups were selected. Ten control group participants received standard healing screws at the surgical stage. Ten individualized healing abutments were Computer aided Design/Computer aided Manufacturing (CAD/CAM)-fabricated out of polyether ether ketone (PEEK) restoration material in a fully digital workflow and seated at the surgical stage in the test group. The modified healing abutment shape was extracted from a virtual library. The standard triangulation language (STL) files of a premolar and a molar were obtained considering the coronal anatomy up to the cement-enamel junction (CEJ). After a healing period ranging from 1 to 3 months depending on the location of the surgical site, namely, mandible or maxilla, a digital impression was taken. The functional implant prosthodontics score (FIPS) and the numerical rating scale (NRS) of pain were recorded and compared. Results: The mean FIPS value for the test group was 9.1 ± 0.9 while the control group mean value was 7.1 ± 0.9. In the test group, pain assessment at crown placement presented a mean value of 0.5 ± 0.7. On the contrary, the control group showed a mean value of 5.5 ± 1.6. Conclusions: Patients in the test group showed higher FIPS values and lower NRS scores during the early phases compared to the control group.
Background: bone augmentation by means of manually shaped titanium mesh is an established procedure to regenerate atrophic alveolar ridges and recreate a proper contour of the peri-implant bone anatomy. Conversely, current literature on the use of preformed titanium meshes instead of traditional grids remains lacking. Therefore, the aim of the present prospective study was to evaluate the use of preformed titanium mesh to support bone regeneration simultaneously to implant placement at dehiscence-type defects from clinical, radiological, and patient-related outcomes. Methods: 8 implants showing buccal dehiscence defects were treated with preformed titanium mesh directly fixed to flat abutments screwed to the implant. Intrasurgical clinical measurements and radiographic evaluations by means of cone-beam computed tomography scans were performed to assess the horizontal bone gain after 8 months from the augmentation surgery. Biological and patient-centered outcomes were also evaluated.; Results: clinically, a mean horizontal bone gain of 4.95 ± 0.96 mm, and a mean horizontal thickness of the buccal plate of 3.25 ± 0.46 mm were found. A mean horizontal bone gain of 5.06 ± 0.88 mm associated with a mean horizontal thickness of the buccal plate of 3.45 ± 0.68 mm were observed radiographically. From a macroscopic aspect, the remodeled graft appeared well integrated with the host bone. Well vascularized newly formed bone-like tissue was observed in intimate contact with the implants. Conclusions: preformed titanium mesh may be effective in supporting simultaneous horizontal bone regeneration at dehiscence-type peri-implant defects. Titanium mesh exposure still remain an issue in this type of surgery.
1 March 2022 in Photodiagnosis and Photodynamic Therapy
Implant rehabilitation is a daily practice in dentistry, and patients often have heightened expectations regarding both the functional and the aesthetic outcome. Implant–abutment connection (IAC) is involved in the long-term aesthetic quality of the rehabilitation. The use of one-piece implants for fixing dentures may prevent the mechanical and biological implication of the implant–abutment interface, resulting in a better quality of hard and soft tissue maintenance. In this case report, we present a novel one-piece implant in a maxillary rehabilitation with a full model-free digital approach.
The quality and quantity of peri-implant soft tissues at the crestal portion of dental implants are important aspects to consider for a long-term successful implant-supported rehabilitation. Some relevant factors attributed to the implant health include mucosal thickness and keratinization. In this respect, many techniques and materials have been described to augment and improve buccal peri-implant soft tissues. Over the last few years, newly developed xenogeneic collagen matrices have been introduced in peri-implant plastic surgery to replace autogenous soft tissue grafts; however, data remain controversial so far. Thus, the purpose of the present report was to present a novel surgical technique conceived to augment buccal peri-implant soft tissues in combination with a volume-stable porcine collagen matrix. The rationale and the fundamental concepts that led to the use of a xenogeneic matrix to increase soft tissue volumes were also discussed.