Hrvoje Bulat

Mr. Hrvoje Bulat

HOPS

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
HBHrvoje Bulat
Hrvoje Bulat
Dubravko FrankovićDubravko Franković
Dubravko Franković
Saša VlahinićSaša Vlahinić
Saša Vlahinić
Contingency analysis (CA) is a well-known function in power system planning and operation. In accordance with CA results, the system operator dispenses information regarding static security of the power system (overloads and/or voltage outside tolerable limits). However, classic CA with remedial action schemes cannot distinguish safe operating regimes from potentially dangerous ones in terms of voltage (in)stability. In fact, voltage instability is considered as one of the major threats leading to power system insecurity. Therefore, in this study an enhanced contingency analysis (ECA) is presented where the classical CA is extended with static voltage analysis based on the modal analysis. The article presents a dedicated methodology for the proposed ECA tool, with special emphasis on the analysis of corrective measures provided by the system operator, intended for enhancing power system security (regulation transformer action, distributed generation and energy storage). Also the influence of the load model was analyzed by simulation and the main conclusions are presented. The study demonstrated the advantages that distributed generation resources and energy storage can provide in the context of voltage stability. Also, the simulations acknowledged the importance of correct load modeling, since over or under estimation of a certain load-type component can result in too optimistic or too pessimistic power system operation limits.
1

17 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
AJAlen Jakoplić
Alen Jakoplić
Dubravko FrankovićDubravko Franković
Dubravko Franković
JHJuraj Havelka
Juraj Havelka
HBHrvoje Bulat
Hrvoje Bulat
With the steady increase in the use of renewable energy sources in the energy sector, new challenges arise, especially the unpredictability of these energy sources. This uncertainty complicates the management, planning, and development of energy systems. An effective solution to these challenges is short-term forecasting of the output of photovoltaic power plants. In this paper, a novel method for short-term production prediction was explored which involves continuous photography of the sky above the photovoltaic power plant. By analyzing a series of sky images, patterns can be identified to help predict future photovoltaic power generation. A hybrid model that integrates both a Convolutional Neural Network (CNN) and a Long Short-Term Memory (LSTM) for short-term production forecasting was developed and tested. This model effectively detects spatial and temporal patterns from images and power output data, displaying considerable prediction accuracy. In particular, a 74% correlation was found between the model’s predictions and actual future production values, demonstrating the model’s efficiency. The results of this paper suggest that the hybrid CNN-LSTM model offers an improvement in prediction accuracy and practicality compared to traditional forecasting methods. This paper highlights the potential of Deep Learning in improving renewable energy practices, particularly in power prediction, contributing to the overall sustainability of power systems.

9 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
Michele RojnićMichele Rojnić
Michele Rojnić
Rene PrencRene Prenc
Rene Prenc
HBHrvoje Bulat
Hrvoje Bulat
Dubravko FrankovićDubravko Franković
Dubravko Franković
The optimization of overcurrent relays’ operation is a topic associated with protection coordination of distribution networks. Usually, this refers to medium-voltage networks, since they are protected by numerical relay devices, as opposed to low-voltage networks, where utility operators allocate fuses. Correct setting of relays and optimal coordination is becoming a serious challenge to Distribution Network Operators around the world, since their networks’ passive operation has been greatly altered in the past two decades. Distributed generation units, a growing liberalized electricity market and more stringent legislation for distribution network planning and operation by state regulatory bodies have all indirectly affected the evolving of protection philosophy for distribution networks. In this paper the traditional optimization problem of overcurrent relay operation will be addressed and critically examined from both a theoretical and practical point of view. Optimization function, constraints and relay parameters will all be observed and compared with solutions used in distribution networks, and their modifications and improvements will be proposed and elaborated in detail.