Saša Vlahinić

Prof. Saša Vlahinić

Faculty of Engineering - University of Rijeka
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Zoran ŠverkoZoran Šverko
Zoran Šverko
MVMiroslav Vrankic
Miroslav Vrankic
Saša VlahinićSaša Vlahinić
Saša Vlahinić
PRPeter Rogelj
Peter Rogelj
In the background of all human thinking—acting and reacting are sets of connections between different neurons or groups of neurons. We studied and evaluated these connections using electroencephalography (EEG) brain signals. In this paper, we propose the use of the complex Pearson correlation coefficient (CPCC), which provides information on connectivity with and without consideration of the volume conduction effect. Although the Pearson correlation coefficient is a widely accepted measure of the statistical relationships between random variables and the relationships between signals, it is not being used for EEG data analysis. Its meaning for EEG is not straightforward and rarely well understood. In this work, we compare it to the most commonly used undirected connectivity analysis methods, which are phase locking value (PLV) and weighted phase lag index (wPLI). First, the relationship between the measures is shown analytically. Then, it is illustrated by a practical comparison using synthetic and real EEG data. The relationships between the observed connectivity measures are described in terms of the correlation values between them, which are, for the absolute values of CPCC and PLV, not lower that 0.97, and for the imaginary component of CPCC and wPLI—not lower than 0.92, for all observed frequency bands. Results show that the CPCC includes information of both other measures balanced in a single complex-numbered index.

10 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
HBHrvoje Bulat
Hrvoje Bulat
Dubravko FrankovićDubravko Franković
Dubravko Franković
Saša VlahinićSaša Vlahinić
Saša Vlahinić
Contingency analysis (CA) is a well-known function in power system planning and operation. In accordance with CA results, the system operator dispenses information regarding static security of the power system (overloads and/or voltage outside tolerable limits). However, classic CA with remedial action schemes cannot distinguish safe operating regimes from potentially dangerous ones in terms of voltage (in)stability. In fact, voltage instability is considered as one of the major threats leading to power system insecurity. Therefore, in this study an enhanced contingency analysis (ECA) is presented where the classical CA is extended with static voltage analysis based on the modal analysis. The article presents a dedicated methodology for the proposed ECA tool, with special emphasis on the analysis of corrective measures provided by the system operator, intended for enhancing power system security (regulation transformer action, distributed generation and energy storage). Also the influence of the load model was analyzed by simulation and the main conclusions are presented. The study demonstrated the advantages that distributed generation resources and energy storage can provide in the context of voltage stability. Also, the simulations acknowledged the importance of correct load modeling, since over or under estimation of a certain load-type component can result in too optimistic or too pessimistic power system operation limits.
1

24 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
Saša VlahinićSaša Vlahinić
Saša Vlahinić
Dubravko FrankovićDubravko Franković
Dubravko Franković
VKVitomir Komen
Vitomir Komen
AAAnamarija Antonić
Anamarija Antonić
Photovoltaic (PV) system inverters usually operate at unitary power factor, injecting only active power into the system. Recently, many studies have been done analyzing potential benefits of reactive power provisioning, such as voltage regulation, congestion mitigation and loss reduction. This article analyzes possibilities for loss reduction in a typical medium voltage distribution system. Losses in the system are compared to the losses in the PV inverters. Different load conditions and PV penetration levels are considered and for each scenario various active power generation by PV inverters are taken into account, together with allowable levels of reactive power provisioning. As far as loss reduction is considered, there is very small number of PV inverters operating conditions for which positive energy balance exists. For low and medium load levels, there is no practical possibility for loss reduction. For high loading levels and higher PV penetration specific reactive savings, due to reactive power provisioning, increase and become bigger than additional losses in PV inverters, but for a very limited range of power factors.

9 January 2009 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Saša VlahinićSaša Vlahinić
Saša Vlahinić
DBDalibor Brnobic
Dalibor Brnobic
NSNino Stojkovic
Nino Stojkovic
Among the different power quality parameters, the voltage total harmonic distortion is important and is often studied. Different indices have previously been suggested to measure and monitor both the current and the voltage distortion in power systems, but the harmonic characterization of a power system can still not be performed in a satisfactory way. The state of the harmonic distortion is difficult to predict due to the variability and a large number of unknowns, such as detailed consumer and system characteristics. In this paper, a new index that describes the total harmonic distortion in the current measurements, i.e., the total rated distortion (TRD), is suggested to simplify and standardize the harmonic current measurements. Another index that represents the increase of the harmonic voltage distortion with TRD, i.e., the equivalent harmonic impedance z eq, is proposed as an efficient way of characterizing a particular site. It is analyzed when z eq is increased or decreased with regard to the angle between the harmonic voltages and currents. Finally, extensive harmonic measurements of a real distribution system were performed to prove the usefulness of the proposed indices.

16 October 2020 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Saša VlahinićSaša Vlahinić
Saša Vlahinić
Dubravko FrankovićDubravko Franković
Dubravko Franković
BJBorna Jurisa
Borna Jurisa
ZZZoran Zbunjak
Zoran Zbunjak
High impedance faults are rather difficult to detect, due to their inherent characteristics. However, in most cases high-impedance low-current faults evolve to low-impedance high-current faults, thus giving rise to life hazard situations and equipment damage. In this paper, a novel back up protection scheme for high impedance fault detection, based on synchrophasor measurement technology, is proposed. In fact, the presented detection method can be thought as the combination of a classic differential and a classic admittance relay. The protection device designated for high impedance fault detection, incorporating the proposed novel protection algorithm, permanently monitors transmission line’s shunt admittance thus being able to detect changes-increase in the resistive part of shunt admittance, namely the shunt conductance. Actually, a sudden rise of transmission line’s shunt conductance is a strong indicator of high impedance fault inception. Conducted computer simulations confirmed a high degree of selectivity and sensitivity of the proposed method. Moreover, the technical feasibility of the approach was tested considering real-world measurement data obtained for two 220 kV transmission lines. From the acquired data, measurement uncertainties of the monitored parameters in normal operating conditions, were calculated. The results demonstrate excellent sensitivity of the proposed method, even for the case of short transmission lines during low-loading conditions.

2 April 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Saša VlahinićSaša Vlahinić
Saša Vlahinić
Dubravko FrankovićDubravko Franković
Dubravko Franković
MDMarijana Zivic Durovic
Marijana Zivic Durovic
NSNino Stojkovic
Nino Stojkovic
Transmission line parameters vary with environmental and operating conditions, thus introducing uncertainties in power flow studies and protection zone settings of relay protection equipment. Variations of line parameters are fundamental for the determination of static and dynamic line power ratings. Usually, nominal values are given without an associated confidence interval, and therefore an important piece of information is missing. With the proliferation of phasor measurement units (PMUs) that allows for synchronized measurements at different geographical positions, arouse the possibility for simple and efficient measurements of line parameters. This article analyzes uncertainties associated with the estimation of line parameters, based on the equivalent π model, valid for short and medium length transmission lines. This problem has been addressed in literature, but only from a theoretical perspective and obtained results were verified with simulations only. Here, measurements conducted on two 220 kV transmission lines are analyzed. It was found that correlation between voltage and current measurements must be taken into consideration when analyzing uncertainty propagation law. Only then statistical analysis of estimations match predictions obtained by applying the theoretical model. Accuracy limits were analyzed as well, but in this case some results were within calculated limits, while others did not follow predictions. Improvements in accuracy limits determination require the separation of environmental and operating condition variations from deviations due to measurement equipment, thus requiring additional information.