Rubens Nisie Tango

Dr. Rubens Nisie Tango

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2008 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
RJRenato Morales Joias
Renato Morales Joias
RTRubens Nisie Tango
Rubens Nisie Tango
JAJose Eduardo Junho de Araujo
Jose Eduardo Junho de Araujo
MAMaria Amelia Junho de Araujo
Maria Amelia Junho de Araujo
GSGuilherme de Siqueira Ferreira Anzaloni Saavedra
Guilherme de Siqueira Ferreira Anzaloni Saavedra
EKEstevao Tomomitsu Kimpara
Estevao Tomomitsu Kimpara

1 November 2014 in Journal of Dentistry
Verified
Journal Article
Closed access
AAA. Arata
A. Arata
TCT.M.B. Campos
T.M.B. Campos
JMJ.P.B. Machado
J.P.B. Machado
DLD.R.R. Lazar
D.R.R. Lazar
VUV. Ussui
V. Ussui
RTRubens Nisie Tango
Rubens Nisie Tango

1 December 2005 in Brazilian Dental Journal
Verified
Journal Article
Open access
PDF file
ACAmérico Bortolazzo Correr
Américo Bortolazzo Correr
MSMário Alexandre Coelho Sinhoreti
Mário Alexandre Coelho Sinhoreti
LSLourenço Correr Sobrinho
Lourenço Correr Sobrinho
RTRubens Nisie Tango
Rubens Nisie Tango
LSLuis Felipe Jochims Schneider
Luis Felipe Jochims Schneider
SCSimonides Consani
Simonides Consani
The aim of this study was to evaluate the effect of the increase of energy density on Knoop hardness of Z250 and Esthet-X composite resins. Cylindrical cavities (3 mm in diameter X 3 mm in depth) were prepared on the buccal surface of 144 bovine incisors. The composite resins were bulk-inserted and polymerized using different light-curing units and times: conventional QTH (quartz-tungsten-halogen; 700 mW/cm²; 20 s, 30 s and 40 s); LED (light-emitting diode; 440 mW/cm²; 20 s, 30 s and 40 s); PAC (xenon plasma arc; 1700 mW/cm²; 3 s, 4.5 s and 6 s). The specimens were stored at 37°C for 24 h prior to sectioning for Knoop hardness assessment. Three measurements were obtained for each depth: top surface, 1 mm and 2 mm. Data were analyzed statistically by ANOVA and Tukey's test (p<0.05). Regardless of the light source or energy density, Knoop hardness of Z250 was statistically significant higher than that of Esthet-X (p<0.05). Specimens cured with PAC had lower hardness than those cured with QTH and LED (p<0.05). Higher Knoop hardness was obtained when the energy density was increased for LED and PAC (p0.05) were found for QTH. Knoop hardness values decreased with the increase of depth. The increase of energy density produced composites with higher Knoop hardness means using LED and PAC.

9 January 2012 in Gerodontology
Verified
Journal Article
Closed access
PDF file
LSLucas H. da Silva
Lucas H. da Silva
SFSabrina A. Feitosa
Sabrina A. Feitosa
Marcia Carneiro ValeraMarcia Carneiro Valera
Marcia Carneiro Valera
MAMaria A.M. de Araujo
Maria A.M. de Araujo
RTRubens Nisie Tango
Rubens Nisie Tango
1

7 December 2017 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
João Paulo Mendes TribstJoão Paulo Mendes Tribst
João Paulo Mendes Tribst
Amanda Dal PivaAmanda Dal Piva
Amanda Dal Piva
JSJamil Awad Shibli
Jamil Awad Shibli
Alexandre BorgesAlexandre Borges
Alexandre Borges
RTRubens Nisie Tango
Rubens Nisie Tango
This study evaluated the effect of implantoplasty on different bone insertion levels of exposed implants. A model of the Bone Level Tapered implant (Straumann Institute, Waldenburg, Switzerland) was created through the Rhinoceros software (version 5.0 SR8, McNeel North America, Seattle, WA, USA). The abutment was fixed to the implant through a retention screw and a monolithic crown was modeled over a cementation line. Six models were created with increasing portions of the implant threads exposed: C1 (1 mm), C2 (2 mm), C3 (3 mm), C4 (4 mm), C5 (5 mm) and C6 (6 mm). The models were made in duplicates and one of each pair was used to simulate implantoplasty, by removing the threads (I1, I2, I3, I4, I5 and I6). The final geometry was exported in STEP format to ANSYS (ANSYS 15.0, ANSYS Inc., Houston, USA) and all materials were considered homogeneous, isotropic and linearly elastic. To assess distribution of stress forces, an axial load (300 N) was applied on the cusp. For the periodontal insert, the strains increased in the peri-implant region according to the size of the exposed portion and independent of the threads’ presence. The difference between groups with and without implantoplasty was less than 10%. Critical values were found when the inserted portion was smaller than the exposed portion. In the exposed implants, the stress generated on the implant and retention screw was higher in the models that received implantoplasty. For the bone tissue, exposure of the implant’s thread was a damaging factor, independent of implantoplasty. Implantoplasty treatment can be safely used to control peri-implantitis if at least half of the implant is still inserted in bone.

1 January 2010 in Operative Dentistry
Verified
Journal Article
Closed access
PCPaula Carolina Komori de Carvalho
Paula Carolina Komori de Carvalho
APA. B. Paula
A. B. Paula
AMA. A. Martin
A. A. Martin
RTRubens Nisie Tango
Rubens Nisie Tango
MSM. A. C. Sinhoreti
M. A. C. Sinhoreti
LCL. Correr-Sobrinho
L. Correr-Sobrinho
SUMMARY: This study evaluated the effect of different light energy densities on conversion degree (CD) and Knoop hardness number (KHN) of RelyX ARC (RLX) resin cement. After manipulation according to the manufacturer's instructions, RLX was inserted into a rubber mold (0.8 mm X 5 mm) and covered with a Mylar strip. The tip of the light-curing unit (LCU) was positioned in contact with the Mylar surface. Quartz-tungsten-halogen (QTH) and light-emitting diode (LED) LCUs with light densities of 10, 20 and 30 J/cm2 were used to light-cure the specimens. After light curing, the specimens were stored dry in lightproof containers at 37°C. After 24 hours, the CD was analyzed by FT-Raman and, after an additional 24-hours, samples were submitted to Knoop hardness testing. The data of the CD (%) and KHN were submitted to two-way ANOVA and the Tukey's test (α=0.05). QTH and LED were effective light curing units. For QTH, there were no differences among the light energy densities for CD or KHN. For LED, there was a significant reduction in CD with the light energy density set at 10 J/cm2. KHN was not influenced by the light-curing unit and by its light energy density.