Weilin Ye

Dr. Weilin Ye

Department of Mechatronics Engineering, College of Engineering, Shantou University, 243#, Daxue Road, Shantou 515063, Guangdong, China
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
BLBin Li
Bin Li
CZChuantao Zheng
Chuantao Zheng
HLHuifang Liu
Huifang Liu
QHQixin He
Qixin He
Weilin YeWeilin Ye
Weilin Ye
YWYiding Wang
Yiding Wang

18 July 2016 in Optics Express
Verified
Journal Article
Open access
PDF file
Weilin YeWeilin Ye
Weilin Ye
CLChunguang Li
Chunguang Li
Chuantao ZhengChuantao Zheng
Chuantao Zheng
NSNancy P. Sanchez
Nancy P. Sanchez
AGAleksander Głuszek
Aleksander Głuszek
FTFrank K. Tittel
Frank K. Tittel
A continuous-wave (CW) interband cascade laser (ICL) based mid-infrared sensor system was demonstrated for simultaneous detection of atmospheric methane (CH4) and ethane (C2H6). A 3.337 µm CW ICL with an emitting wavenumber range of 2996.0−3001.5 cm−1 was used to simultaneously target two absorption lines, C2H6 at 2996.88 cm−1 and CH4 at 2999.06 cm−1, respectively. The sensor performance was first evaluated for single-gas detection by only targeting the absorption line of one gas species. Allan deviations of 11.2 parts per billion in volume (ppbv) for CH4 and 1.86 ppbv for C2H6 with an averaging time of 3.4 s were achieved for the detection of these two gases. Dual-gas detection was realized by using a long-term scan signal to target both CH4 and C2H6 lines. The Allan deviations increased slightly to 17.4 ppbv for CH4 and 2.4 ppbv for C2H6 with an averaging time of 4.6 s due to laser temperature and power drift caused by long-term wavelength scanning. Measurements for both indoor and outdoor concentration changes of CH4 and C2H6 were conducted. The reported single ICL based dual-gas sensor system has the advantages of reduced size and cost compared to two separate sensor systems.

6 July 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
HZHuadan Zheng
Huadan Zheng
MLMinhan Lou
Minhan Lou
Lei DongLei Dong
Lei Dong
HWHongpeng Wu
Hongpeng Wu
Weilin YeWeilin Ye
Weilin Ye
FTFrank K. Tittel
Frank K. Tittel
A photoacoustic module (PAM) for methane detection was developed by combining a novel 3.2 μm interband cascade light emitting device (ICLED) with a compact differential photoacoustic cell. The ICLED with a 22-stage interband cascade active core emitted a collimated power of ~700 μW. A concave Al-coat reflector was positioned adjacent to the photoacoustic cell to enhance the gas absorption length. Assembly of the ICLED and reflector with the photoacoustic cell resulted in a robust and portable PAM without any moving parts. The PAM performance was evaluated in terms of operating pressure, sensitivity and linearity. A 1σ detection limit of 3.6 ppmv was achieved with a 1-s integration time.

1 June 2017 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
CZChuantao Zheng
Chuantao Zheng
Weilin YeWeilin Ye
Weilin Ye
NSNancy P. Sanchez
Nancy P. Sanchez
CLChunguang Li
Chunguang Li
Lei DongLei Dong
Lei Dong
FTFrank K. Tittel
Frank K. Tittel

26 April 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
MDMing Dong
Ming Dong
Chuantao ZhengChuantao Zheng
Chuantao Zheng
DYDan Yao
Dan Yao
GZGuoqiang Zhong
Guoqiang Zhong
SMShuzhuo Miao
Shuzhuo Miao
FTFrank K. Tittel
Frank K. Tittel
Design and fabrication of a dual spot-ring Herriott cell (DSR-HC) were proposed. The sealed Herriott cell with a dimensional size of 5.5 cm × 9.2 cm × 32.1 cm, possessed two input/output coupling holes leading to two absorption path lengths of ~20 m and ~6 m, respectively. An acetylene (C2H2) sensor system with a double-range was developed using the DSR-HC and wavelength modulation spectroscopy (WMS) technique. A near-infrared distributed feedback (DFB) laser was employed for targeting a C2H2 absorption line at 6521.2 cm−1. C2H2 concentration measurements were carried out by modulating the laser at a 5 kHz frequency and demodulating the detector signal with LabVIEW software. An Allan-Werle deviation analysis indicated that the limit of detection (LoD) for the two absorption path lengths of 20 m and 6 m are 7.9 parts-per-million in volume (ppmv) and 4.0 ppmv, respectively. The DSR-HC concept can be used to fabricate similar cells for single-gas detection requiring two different detection ranges as well as for dual-gas detection requiring different absorption path lengths.

1 April 2022 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
YLYafei Li
Yafei Li
LYLing Yu
Ling Yu
Chuantao ZhengChuantao Zheng
Chuantao Zheng
ZMZhuo Ma
Zhuo Ma
SYShuo Yang
Shuo Yang
FTFrank K. Tittel
Frank K. Tittel