Matrix metalloproteinase (MMP) inhibition has been shown to reduce adhesive bond degradation when applied as a pre-conditioner, adding to clinical steps in the placement of adhesives, but their incorporation within dental adhesives has not been fully explored. This study examined the effect of including 2 MMP inhibitors (BB94 and GM6001) within the primers of 3 commercially available adhesives. Fluorometric assay and zymography showed that adhesives with MMP inhibitors had high affinity toward both synthetic fluorogenic FRET peptides (95%) and dentin powder substrates, respectively. The immediate microtensile bond strength was enhanced for 2 types of adhesives following the addition of both inhibitors. However, no changes were detected between the control and the inhibitor groups following 3-month storage. The modified two-step etch-and-rinse and single-step systems showed less Rhodamine B penetration to the “hybrid layer” and to the “adhesive”, respectively. The incorporation of BB94 and GM6001 within the primers resulted in the inhibition of dentin MMPs with improved initial bond strength and enhanced sealing ability.
The aim of this study was to evaluate and correlate objectively the microspectroscopically derived biochemical components of sound, infected and affected carious dentine with their microhardness and autofluorescence (AF) characteristics. Over 3 million high-resolution Raman spectra from 8 extracted human carious teeth were recorded using Raman spectrometer with parallel spectrum acquisition. Green AF signals across each carious lesion from all samples were acquired with a similar spatial resolution using confocal fluorescence microscopy. The Knoop microhardness (KHN) from a total of 233 co-localized areas was recorded from the same samples and allocated subjectively into the three zones. Cluster analysis of the Raman data, performed using in-house software, produced five independent spectral components representing mineral content, protein content, porphyrin fluorescence (PF), putative infected dentine signal (IDS) and affected dentine signal (ADS). The distributions of the 5 Raman components and the AF signal were matched across all samples and their average values were calculated for each corresponding KHN area. The infected dentine was defined significantly by the KHN, AF and by the relative contribution of the mineral, PF and IDS clusters. Protein cluster was not statistically related to the KHN or AF. A delineation between affected and sound dentine was observed using the KHN, AF, PF and ADS parameters. This study concludes that micro-Raman spectroscopy can provide a non-invasive and objective evaluation of different carious dentine zones. Being able to detect and assess clinically the caries-affected dentine during minimally invasive operative caries management is important to control the risk of unnecessary tissue removal.
The aim of this study was to evaluate the effect of universal adhesives (UA) and silane on the microtensile bond strength (μTBS) of resin cement to a hybrid ceramic Vita Enamic (VE). VE specimens were acid etched using hydrofluoric acid (HF) and were assigned to three groups (n = 10) based on the applied bonding technique. In group 1 (S), a silane-based primer was used as a surface treatment prior to the application of a resin cement (Variolink Esthetic DC). In group 2, a silane-containing UA, Clearfil Universal Bond (CUB) was used for the surface treatment, and in group 3, A silane-free UA, Tetric N-Bond Universal (TNU) was used for surface treatment. Resin cement build-ups were prepared. The bonded specimens were sectioned into resin-ceramic beams. Half of the beams of each group were stored for 24 h at 37 °C and the other half were subjected to a thermo-cycling aging. The microtensile bond strength (μTBS) was measured at a crosshead speed of 0.5 mm/min. Failure modes were assessed accordingly. Data were analyzed using a) two-way analysis of variance ANOVA followed by one-way ANOVA and Tukey tests between groups and b) independent t-test to detect differences (α = 0.05) for each group. The surface topographies of the ceramic surface were evaluated using scanning electron microscopy. The results showed that silane-based primer (S) application resulted in significantly higher (p < 0.05) μTBS values after 24 h and after thermocycling compared to both silane-containing UA (CUB) and silane-free UA (TNU). The μTBS values of all groups were significantly reduced after thermocycling. No statistically significant difference was observed between the μTBS of CUB and TNU after 24 h. However, TNU showed significantly higher μTBS after thermocycling. Different failure modes were observed, and adhesive failure was the most common in all groups. Marked surface topographic changes were observed following HF etching. It is concluded that, the UAs tested cannot be recommended as substitutes to the silanization of Hybrid ceramic.
Background. Suturing plays a critical role in the healing of surgical wounds. The tensile strength of suture materials indicates the ability of the material to withstand stress during knotting and protect the wound during an extended period of healing. Objective. An in vitro study was conducted to determine the effect of two commercially available mouthwashes on the tensile strength and breakage mode of two absorbable intraoral sutures. Materials and Methods. Two common absorbable sutures, Vicryl® and Monocryl®, both with 4-0 and 5-0 gauges were used. A total of 400 specimens were sutured around rubber rods and immersed in three thermostatically controlled experimental conditions: artificial saliva, 0.2% chlorhexidine gluconate (Parodontax® extra), and essential oils-based rinse (Listerine® Zero™), and these were compared to a nonimmersed dry condition. All specimens were stored in an incubator at 37°C. Tensile strengths were assessed after days 1, 3, 7, 10, and 14 of immersion using a universal Instron® testing machine. The maximum load for suture breakage and the location of the point of breakage were assessed. Results. Unlike Monocryl® 4-0, the tensile strength of both gauges of Vicryl® sutures significantly increased in chlorhexidine and Listerine®. There was a significant decrease in the strength for all suture types after day 10, regardless of the immersion solution. Listerine® significantly reduced the tensile strength of Monocryl® 5-0. Conclusion. Oral surgeons and periodontists should be cautious when prescribing commercial mouthwashes for patients relative to their selection of suture materials. However, further studies are needed to understand the molecular changes in sutures when exposed to chemical solutions found in mouthwashes.
Background: Sealing occlusal pits and fissures is an effective preventive measure against dental caries. Pit and fissure sealants (PFS) should be strongly bonded to the teeth to prevent partial or complete loss of the sealant, which may limit its preventive effect. Objective: The objective of the study was to compare the microtensile bond strength (μTBS) of bioactive resin-based sealants (Bio-RBS) and resin-based sealants (RBS), with and without the use of a bonding agent, to the enamel of primary and permanent teeth. Methods: One hundred and twenty caries-free primary molar specimens and 120 permanent molar specimens were divided to eight groups (30 specimens per group), both primary and permanent teeth were sealed with a Bio-RBS BioCoatTM (Premier®, Plymouth Meeting, PA, USA) or with a RBS ClinproTM (3M ESPE, Saint Paul, MN, USA), with or without the use of a bonding agent (Prime & Bond NT; Dentsply, Inc., Charlotte, NC, USA). Half the specimens were aged with 5000 thermal cycles, and all specimens were tested for the μTBS and failure mode. Results: The mean μTBS of aged Bio-RBS was higher in permanent teeth than primary teeth, and the aging process reduced the μTBS of RBS more than that of Bio-RBS. Moreover, the addition of a bonding agent improved the μTBS of aged RBS in permanent teeth. Conclusion: We concluded that Bio-RBS exhibit superior μTBS than RBS when applied to permanent teeth.