Mohamed Moustafa Awad

Dr. Mohamed Moustafa Awad

College of dentistry, Prince Sattam Bin abdulaziz university
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2017 in Journal of Adhesion Science and Technology
Verified
Journal Article
Closed access
AAAli Alrahlah
Ali Alrahlah
Mohamed Moustafa AwadMohamed Moustafa Awad
Mohamed Moustafa Awad
FVFahim Vohra
Fahim Vohra
AAAbdulellah Al-Mudahi
Abdulellah Al-Mudahi
ZJZaid A. Al Jeaidi
Zaid A. Al Jeaidi
MEMohamed Elsharawy
Mohamed Elsharawy

9 October 2022 in Biomimetics
Verified
Journal Article
Open access
PDF file
AAAbdullah Alshehri
Abdullah Alshehri
FAFeras Alhalabi
Feras Alhalabi
Mohammed MustafaMohammed Mustafa
Mohammed Mustafa
Mohamed Moustafa AwadMohamed Moustafa Awad
Mohamed Moustafa Awad
MAMohammed Alqhtani
Mohammed Alqhtani
AAAbdulrahman Alshabib
Abdulrahman Alshabib
The aim of this in vitro study is to compare the color stability and surface roughness of conventional and self-blending resin composites before and after staining and aging. Three conventional composites (Filtek Z350, IPS Empress Direct, and Estalite Palfique LX5) and one self-blending (Omnichroma) resin composite were used in this study. Sixty discs were prepared and polymerized in a metal mold (n = 15 per group). Samples were then finished and polished by Layan discs. Color testing and roughness testing were measured as a baseline (T0) by a spectrophotometer and profilometry. Samples were then stained with tea for 24 h, water aged for 30 days, and then a second reading (T1) was performed. Finishing and polishing were performed again, and a third reading (T2) was collected. All groups showed significant decrease in all color parameters (L*, a*, and b*); however, after polishing, all groups showed color enhancements matching pre-experiment baseline colors in all color parameters (L*, a*, and b*), except for Estelite Palfique LX5, which showed a significant difference in L relative to the baseline. Furthermore, Estalite Palfique LX5 showed increased roughness after staining compared to the baseline, unlike other groups. No significant differences in color stability were found between self-blending composites and other composite materials. Accelerated aging and staining had minimal effects on the surface roughness of self-blending composite.

28 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
Mohamed Moustafa AwadMohamed Moustafa Awad
Mohamed Moustafa Awad
FAFeras Alhalabi
Feras Alhalabi
KAKhaled M. Alzahrani
Khaled M. Alzahrani
MAMajed Almutiri
Majed Almutiri
Fawaz AlqanawiFawaz Alqanawi
Fawaz Alqanawi
MAMohammed Ahmed
Mohammed Ahmed
Contamination of zirconia restorations before cementation can impair the resin–zirconia bonding durability. The objective of this study was to evaluate the effect of human saliva or blood decontamination with 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP)-containing cleaner on the resin–zirconia shear bond strength (SBS). Methods: A total of 220 zirconia specimens were prepared and air-abraded and randomly distributed into 11 groups (n = 20 per group). Except for the control group (no contamination), zirconia specimens were contaminated with either human saliva (five groups) or blood (five groups), and then subjected to one of five cleaning methods: water rinsing, 38% phosphoric acid etchant (Pulpdent Corp., Watertown, MA, USA), 70% isopropanol alcohol (Avalon Pharma, Riyadh, Saudi Arabia), Ivoclean (Ivoclar Vivadent, Schaan, Lichtenstein) and Katana Cleaner (Kuraray Noritake, Tokyo, Japan). The resin–zirconia SBS was tested at 24 h and after thermocycling (10 k cycles). Three-way ANOVA followed by Tukey’s multiple comparisons test were utilized to analyze the SBS data. Failure modes were evaluated using a scanning electron microscope. Results: Both blood and saliva significantly affected resin–zirconia SBS as contaminants. After thermocycling, there was no statistically significant difference between SBS obtained after decontamination with the Katana Cleaner (blood, 6.026 ± 2.805 MPa; saliva, 5.206 ± 2.212 MPa) or Ivoclean (blood, 7.08 ± 3.309 MPa; saliva, 6.297 ± 3.083 MPa), and the control group (no contamination, 7.479 ± 3.64 MPa). Adhesive and mixed failures were the most frequent among the tested groups. Conclusion: Both 10-MDP-containing cleaner (Katana Cleaner) and zirconium oxide-containing cleaner (Ivoclean) could eliminate the negative effect of saliva and blood contamination on resin–zirconia SBS.

6 August 2019 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
Mohamed Moustafa AwadMohamed Moustafa Awad
Mohamed Moustafa Awad
LALamees Albedaiwi
Lamees Albedaiwi
AAAhmed Almahdy
Ahmed Almahdy
RKRawaiz Khan
Rawaiz Khan
Nikolaos SilikasNikolaos Silikas
Nikolaos Silikas
AAAli Alrahlah
Ali Alrahlah
The aim of this study was to evaluate the effect of universal adhesives (UA) and silane on the microtensile bond strength (μTBS) of resin cement to a hybrid ceramic Vita Enamic (VE). VE specimens were acid etched using hydrofluoric acid (HF) and were assigned to three groups (n = 10) based on the applied bonding technique. In group 1 (S), a silane-based primer was used as a surface treatment prior to the application of a resin cement (Variolink Esthetic DC). In group 2, a silane-containing UA, Clearfil Universal Bond (CUB) was used for the surface treatment, and in group 3, A silane-free UA, Tetric N-Bond Universal (TNU) was used for surface treatment. Resin cement build-ups were prepared. The bonded specimens were sectioned into resin-ceramic beams. Half of the beams of each group were stored for 24 h at 37 °C and the other half were subjected to a thermo-cycling aging. The microtensile bond strength (μTBS) was measured at a crosshead speed of 0.5 mm/min. Failure modes were assessed accordingly. Data were analyzed using a) two-way analysis of variance ANOVA followed by one-way ANOVA and Tukey tests between groups and b) independent t-test to detect differences (α = 0.05) for each group. The surface topographies of the ceramic surface were evaluated using scanning electron microscopy. The results showed that silane-based primer (S) application resulted in significantly higher (p < 0.05) μTBS values after 24 h and after thermocycling compared to both silane-containing UA (CUB) and silane-free UA (TNU). The μTBS values of all groups were significantly reduced after thermocycling. No statistically significant difference was observed between the μTBS of CUB and TNU after 24 h. However, TNU showed significantly higher μTBS after thermocycling. Different failure modes were observed, and adhesive failure was the most common in all groups. Marked surface topographic changes were observed following HF etching. It is concluded that, the UAs tested cannot be recommended as substitutes to the silanization of Hybrid ceramic.

1 December 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
CFC. Fu
C. Fu
SDS. Deng
S. Deng
IKI. Koneski
I. Koneski
Mohamed Moustafa AwadMohamed Moustafa Awad
Mohamed Moustafa Awad
ZAZohaib Akram
Zohaib Akram
Amr FawzyAmr Fawzy
Amr Fawzy

1 April 2019 in International Journal of Adhesion and Adhesives
Verified
Journal Article
Closed access
Mohamed Moustafa AwadMohamed Moustafa Awad
Mohamed Moustafa Awad
AAAli Alrahlah
Ali Alrahlah
JMJukka P. Matinlinna
Jukka P. Matinlinna
HHHamdi HAMAMA
Hamdi HAMAMA