Aims: To examine the mid-term outcome and cost utility of the BioPro metallic hemiarthroplasty for the treatment of hallux rigidius. Patients and Methods: We reviewed 97 consecutive BioPro metallic hemiarthroplasties performed in 80 patients for end-stage hallux rigidus, with a minimum follow-up of five years. There were 19 men and 61 women; their mean age was 55 years (22 to 74). No patient was lost to follow-up. Results: A total of 12 patients (15 first metatarso-phalangeal joints (MTPJs)) required a revision; one for infection, two for osteolysis and 12 for pain. The all cause rate of survival at five years was 85.6% (95% confidence interval (CI) 83.5 to 87.9). Younger age was a significant predictor of revision (odds ratio 1.09, 95% CI 1.02 to 1.17, p = 0.014) on excluding infection and adjusting for confounding variables (Cox regression). Significant improvements were demonstrated at five years in the Manchester Oxford Foot Questionnaire (13.9, 95% CI 10.5 to 17.2) and in the physical component of the Short Form-12 score (6.5, 95% CI 4.1 to 8.9). The overall rate of satisfaction was 75%. The cost per quality adjusted life year at five years, accounting for a 14% rate of revision was between £4431 and £6361 depending on the complexity and morbidity of the patient. Conclusion: The BioPro hemiarthroplasty offers good short to mid-term functional outcome and is a cost effective intervention. The relatively high revision rate is associated with younger age and perhaps the use of this implant should be limited to older patients. Cite this article: Bone Joint J 2016;98-B:945–51.
The temporomandibular joint (TMJ) is a critical joint for the opening and closing of the mouth. The generation of customised TMJs according to individuals’ dental anatomy is needed. Currently, the implants available on the market lack consideration of the patient’s dental anatomy. This leads to the creation of an imbalance in the reaction forces on both ends of the TMJ. This requires a slight structural change in the design parameters to give a solution. The purpose of this study is to propose a new design that includes the geometry and materials for a TMJ implant. Stress analysis was carried out on the TMJ to balance the reaction forces at both TMJ ends. A static analysis was performed using ANSYS Workbench, to compare the results of two customised designs of TMJ implants, in order to better balance the reaction forces at both ends. The model in the study showed that the reaction forces for both the patient-specific TMJ implants were nearly balanced. The reaction forces were better balanced, and almost equivalent to the intact conditions. The stresses in the mandible were more uniformly distributed in the customised design of the TMJ implant. The two types of design showed that the custom design took up less space in the patient’s region of surgery, making it a better option compared to a stock TMJ implant. The custom implant would allow faster patient rehabilitation, as the reaction forces would be close to those in intact conditions.