Yousef Al-handarish

Dr. Yousef Al-handarish

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2019 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
TITobore Igbe
Tobore Igbe
JLJingzhen Li
Jingzhen Li
LYLiu Yuhang
Liu Yuhang
YAYousef Al-handarish
Yousef Al-handarish
AKAbhishek Kandwal
Abhishek Kandwal
Lei WangLei Wang
Lei Wang
The use of deep learning (DL) for the analysis and diagnosis of biomedical and health care problems has received unprecedented attention in the last decade. The technique has recorded a number of achievements for unearthing meaningful features and accomplishing tasks that were hitherto difficult to solve by other methods and human experts. Currently, biological and medical devices, treatment, and applications are capable of generating large volumes of data in the form of images, sounds, text, graphs, and signals creating the concept of big data. The innovation of DL is a developing trend in the wake of big data for data representation and analysis. DL is a type of machine learning algorithm that has deeper (or more) hidden layers of similar function cascaded into the network and has the capability to make meaning from medical big data. Current transformation drivers to achieve personalized health care delivery will be possible with the use of mobile health (mHealth). DL can provide the analysis for the deluge of data generated from mHealth apps. This paper reviews the fundamentals of DL methods and presents a general view of the trends in DL by capturing literature from PubMed and the Institute of Electrical and Electronics Engineers database publications that implement different variants of DL. We highlight the implementation of DL in health care, which we categorize into biological system, electronic health record, medical image, and physiological signals. In addition, we discuss some inherent challenges of DL affecting biomedical and health domain, as well as prospective research directions that focus on improving health management by promoting the application of physiological signals and modern internet technology.

8 January 2020 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
YAYousef Al-handarish
Yousef Al-handarish
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
TITobore Igbe
Tobore Igbe
SHShipeng Han
Shipeng Han
HLHui Li
Hui Li
Lei WangLei Wang
Lei Wang
Over the past few decades, tactile sensors have become an emerging field of research in both academia and industry. Recent advances have demonstrated application of tactile sensors in the area of biomedical engineering and opened up new opportunities for building multifunctional electronic skin (e‐skin) which is capable of imitating the human sense‐of‐touch for medical purposes. Analyses have shown that current smart tactile sensing technology has the advantages of high performance, low‐cost, time efficiency, and ease‐of‐fabrication. Tactile sensing systems have thus sufficiently matured for integration into several fields related to biomedical engineering. Furthermore, artificial intelligence has the potential for being applied in human‐machine interfacing, for instance, in medical robotic manipulation, especially during minimally invasive robotic surgery, where tactile sensing is usually a problem. In this survey, we present a comprehensive review of the state of the art of tactile sensors. We focus on the technical details of transduction mechanisms such as piezoresistivity, capacitance, piezoelectricity, and triboelectric and highlight the role of novel and commonly used materials in tactile sensing. In addition, we discuss contributions that have been reported in the field of biomedical engineering, which includes its present and future applications in building multifunctional e‐skins, human‐machine interfaces, and minimally invasive surgical robots. Finally, some challenges and notable improvements that have been made in the technical aspects of tactile sensing systems are reported.

19 February 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Toluwanimi Oluwadara AkinyemiToluwanimi Oluwadara Akinyemi
Toluwanimi Oluwadara Akinyemi
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
WDWenke Duan
Wenke Duan
GLGan Lu
Gan Lu
YAYousef Al-handarish
Yousef Al-handarish
Lei WangLei Wang
Lei Wang
The adoption of non-surgical procedures for the treatment of cardiovascular diseases has yielded several benefits such as lesser perioperative pain, shorter hospital stay, and faster recovery time while introducing radiation-specific, orthopedic, force-related health risks etc. during manual procedures. To address these challenges, robotic catheter systems were unveiled for better procedural outcomes while also offering a vast decline in orthopedic and radiation risks witnessed aforetime. However, distal force sensing and feedback acquisition were lacking in most of these systems. Currently, miniaturized force-sensing catheters for smart catheterization and acquisition of tool-tissue or tool-vessel contact force rely mostly on electrical or optical-based approaches with fiber Bragg grating (FBG) sensing technique receiving an increased attention lately. Hence, this paper presents an extensive overview of FBG-based distal force sensors for both conventional and robot-assisted cardiac interventions with emphasis on its fundamental principles, progressive development, design methodology, significance, as well as current challenges. In addition, the safety and feasibility of existing robotic catheter systems was analyzed based on existing studies. An outlook on future improvement of robotic catheter systems and adoption of FBG-based distal force sensors for wider minimally invasive applications were presented.

29 September 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
YAYousef Al-handarish
Yousef Al-handarish
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
WDWen ke Duan
Wen ke Duan
JCJing Chen
Jing Chen
LZLuo Zebang
Luo Zebang
Lei WangLei Wang
Lei Wang
Recently, flexible tactile sensors based on three-dimensional (3D) porous conductive composites, endowed with high sensitivity, a wide sensing range, fast response, and the capability to detect low pressures, have aroused considerable attention. These sensors have been employed in different practical domain areas such as artificial skin, healthcare systems, and human–machine interaction. In this study, a facile, cost-efficient method is proposed for fabricating a highly sensitive piezoresistive tactile sensor based on a 3D porous dielectric layer. The proposed sensor is designed with a simple dip-coating homogeneous synergetic conductive network of carbon black (CB) and multi-walled carbon nanotube (MWCNTs) composite on polydimethysiloxane (PDMS) sponge skeletons. The unique combination of a 3D porous structure, with hybrid conductive networks of CB/MWCNTs displayed a superior elasticity, with outstanding electrical characterization under external compression. The piezoresistive tactile sensor exhibited a high sensitivity of (15 kPa−1), with a rapid response time (100 ms), the capability of detecting both large and small compressive strains, as well as excellent mechanical deformability and stability over 1000 cycles. Benefiting from a long-term stability, fast response, and low-detection limit, the piezoresistive sensor was successfully utilized in monitoring human physiological signals, including finger heart rate, pulses, knee bending, respiration, and finger grabbing motions during the process of picking up an object. Furthermore, a comprehensive performance of the sensor was carried out, and the sensor’s design fulfilled vital evaluation metrics, such as low-cost and simplicity in the fabrication process. Thus, 3D porous-based piezoresistive tactile sensors could rapidly promote the development of high-performance flexible sensors, and make them very attractive for an enormous range of potential applications in healthcare devices, wearable electronics, and intelligent robotic systems.

7 April 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
SHShipeng Han
Shipeng Han
YAYousef Al-handarish
Yousef Al-handarish
WDWenjing Du
Wenjing Du
WDWen ke Duan
Wen ke Duan
Lei WangLei Wang
Lei Wang
Success of the da Vinci surgical robot in the last decade has motivated the development of flexible access robots to assist clinical experts during single-port interventions of core intrabody organs. Prototypes of flexible robots have been proposed to enhance surgical tasks, such as suturing, tumor resection, and radiosurgery in human abdominal areas; nonetheless, precise constraint control models are still needed for flexible pathway navigation. In this paper, the design of a flexible snake-like robot is presented, along with the constraints model that was proposed for kinematics and dynamics control, motion trajectory planning, and obstacle avoidance during motion. Simulation of the robot and implementation of the proposed control models were done in Matlab. Several points on different circular paths were used for evaluation, and the results obtained show the model had a mean kinematic error of 0.37 ± 0.36 mm with very fast kinematics and dynamics resolution times. Furthermore, the robot’s movement was geometrically and parametrically continuous for three different trajectory cases on a circular pathway. In addition, procedures for dynamic constraint and obstacle collision detection were also proposed and validated. In the latter, a collision-avoidance scheme was kept optimal by keeping a safe distance between the robot’s links and obstacles in the workspace. Analyses of the results showed the control system was optimal in determining the necessary joint angles to reach a given target point, and motion profiles with a smooth trajectory was guaranteed, while collision with obstacles were detected a priori and avoided in close to real-time. Furthermore, the complexity and computational effort of the algorithmic models were negligibly small. Thus, the model can be used to enhance the real-time control of flexible robotic systems.

13 March 2020 in IEEE Access
Verified
Journal Article
Open access
WDWenjing Du
Wenjing Du
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
WDWen ke Duan
Wen ke Duan
TZTao Zhou
Tao Zhou
XLXiaodan Lv
Xiaodan Lv
LWLei Wang
Lei Wang
Despite the great proven advantages of imaging techniques in percutaneous coronary interventions (PCIs), the recent rapid increase in the number of PCI procedures exposes both surgical experts and patients to more radiation and orthopedic hazards in the intervention room. While patients are minimally exposed, many appearance of interventionists subject them to frequent exposure of the operational hazards. Despite promoting the use of robot-assisted intravascular PCI in the Cath-Labs, cognitive and technical skills of interventionists’ are yet to be explored towards reducing procedure time and minimal exposure of surgeon to operational hazards. In this study, a random forest classification framework is developed for proper identification of technical manipulation skills of surgeons along with underlying motion patterns of the flexible intravascular tools (viz. guidewire and catheter) during PCI catheterization. For this purpose, analysis of interventionists’ muscular activities and related hand motion were decoded from physiological signals recorded with sensors. Surface electromyography, electromagnetic, and tactile force signals were acquired concurrently from seven interventionists during specified guidewire movement viz. pull, push, rotate-pull (clockwise rotation with pull), rotate-push (counterclockwise rotation with push), CR (clockwise rotation), and CCR (counterclockwise rotation). While relations were established between force and muscle activities in the surgeon groups using Spearman's Rank-Order statistical method, Wilcoxon test and Kruskal-Wallis one-way ANOVA test were employed to identify intra-group and inter-group differences. From the experimental results obtained, guidewire delivery patterns exhibit stable characteristics with overall classification accuracies of 94.11% based on nineteen features subset from muscle activities and hand motion, followed by 88.01% based on twelve features subset from muscle activities, 71.97% based on seven features subset from hand motion, 84.56% based on ten features subset from part muscle activities and hand motion. Thus, this study shows existence of significant correlation (p < 0.05) between force and muscle activity during intravascular catheterization for PCIs, while comparably high tactile force values were experience in vascular model with plaque or stenosis.