Su-hyun Hwang

Ms. Su-hyun Hwang

Dental and Life Science Institute of Pusan National University
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
YSYong-Ho Seo
Yong-Ho Seo
SHSu-hyun Hwang
Su-hyun Hwang
YKYu-Na Kim
Yu-Na Kim
HKHyung Joon Kim
Hyung Joon Kim
EBEun-Bin Bae
Eun-Bin Bae
JHJung-Bo Huh
Jung-Bo Huh
In this study, we aimed to investigate the bone regeneration efficiency of two-layer porcine-derived bone scaffolds composed of cancellous and cortical bones in a rabbit calvarial defect model. Four circular calvaria defects were formed on cranium of rabbit and were filled with block bone scaffolds of each group: cortical bone block (Cortical group), cancellous bone block (Cancellous group), and two-layer bone block (2layer group). After 8 weeks, new bones were primarily observed in cancellous parts of the Cancellous and 2layer groups, while the Cortical group exhibited few new bones. In the results of new bone volume and area analyses, the Cancellous group showed the highest value, followed by the 2layer group, and were significantly higher than the Cortical group. Within the limitations of this study, the cancellous and two-layer porcine-derived bone scaffolds showed satisfactory bone regeneration efficiency; further studies on regulating the ratio of cortical and cancellous bones in two-layer bones are needed.

13 June 2021 in Materials
Verified
Journal Article
Open access
PDF file
WCWon-Tak Cho
Won-Tak Cho
So-Yeun KimSo-Yeun Kim
So-Yeun Kim
SJSung-In Jung
Sung-In Jung
SKSeong Soo Kang
Seong Soo Kang
SKSe Eun Kim
Se Eun Kim
JHJung-Bo Huh
Jung-Bo Huh
This study aimed to compare two methods of crosslinking collagen type I on implanted titanium surfaces, that is, using glutaraldehyde (GA) or gamma-rays (GRs), in a beagle dog model. For in vivo experiments, implants were allocated to three groups and applied to mandibular bone defects in beagle dogs; Group SLA; non-treated Sandblasted, large grit, acid-etched (SLA) implants, Group GA; SLA implants coated with GA crosslinked collagen type I, Group GR; SLA surface implants coated with collagen type I and crosslinked using 25 kGy of 60Co gamma radiation. New bone μCT volumes were obtained, and histologic and histometric analyses were performed in regions of interest. The GR group had significantly better new bone areas (NBAs) and bone to implant contact (BIC) results than the SLA group (p < 0.05), but the GA and GR groups were similar in this respect. New bone volumes and inter-thread bone densities (ITBD) were non-significantly different in the three groups (p > 0.05). Within the limits of this study, gamma-ray collagen crosslinking on titanium implants can be considered a substitute for glutaraldehyde crosslinking.

23 February 2023 in Materials
Verified
Journal Article
Open access
PDF file
SHSu-hyun Hwang
Su-hyun Hwang
KMKeumok Moon
Keumok Moon
WDWen Du
Wen Du
WCWon-Tak Cho
Won-Tak Cho
JHJung-Bo Huh
Jung-Bo Huh
EBEun-Bin Bae
Eun-Bin Bae
In this study, hydroxypropyl methylcellulose (HPMC) was mixed with particle-type xenografts, derived from two different species (bovine and porcine), to increase the manipulability of bone grafts and compare the bone regeneration ability. Four circular defects with a diameter of 6 mm were formed on each rabbit calvaria, and the defects were randomly divided into three groups: no treatment (control group), HPMC-mixed bovine xenograft (Bo-Hy group), and HPMC-mixed porcine xenograft (Po-Hy group). At eight weeks, micro-computed tomography (µCT) scanning and histomorphometric analyses were performed to evaluate new bone formation within the defects. The results revealed that the defects treated with the Bo-Hy and the Po-Hy showed higher bone regeneration than the control group (p < 0.05), while there was no significant difference between the two xenograft groups (p > 0.05). Within the limitations of the present study, there was no difference in new bone formation between porcine and bovine xenografts with HPMC, and bone graft material was easily moldable with the desired shape during surgery. Therefore, the moldable porcine-derived xenograft with HPMC used in this study could be a promising substitute for the currently used bone grafts as it exhibits good bone regeneration ability for bony defects.

9 August 2021 in Materials
Verified
Journal Article
Open access
PDF file
So-Yeun KimSo-Yeun Kim
So-Yeun Kim
YLYou-Jin Lee
You-Jin Lee
WCWon-Tak Cho
Won-Tak Cho
SHSu-hyun Hwang
Su-hyun Hwang
SHSoonchul Heo
Soonchul Heo
JHJung-Bo Huh
Jung-Bo Huh
The purpose of this study was to evaluate the bone-generating ability of a new bovine-derived xenograft (S1-XB) containing hydrogel. For control purposes, we used Bio-Oss and Bone-XB bovine-derived xenografts. S1-XB was produced by mixing Bone-XB and hydrogel. Cell proliferation and differentiation studies were performed to assess cytotoxicities and cell responses. For in vivo study, 8 mm-sized cranial defects were formed in 16 rats, and then the bone substitutes were transplanted into defect sites in the four study groups, that is, a Bio-Oss group, a Bone-XB group, an S1-XB group, and a control (all n = 4); in the control group defects were left empty. Eight weeks after surgery, new bone formation areas were measured histomorphometrically. In the cell study, extracts of Bio-Oss, Bone-XB, and S1-XB showed good results in terms of the osteogenic differentiation of human mesenchymal stem cells (hMSCs) and no cytotoxic reaction was evident. No significant difference was observed between mean new bone areas in the Bio-Oss (36.93 ± 4.27%), Bone-XB (35.07 ± 3.23%), and S1-XB (30.80 ± 6.41%) groups, but new bone area was significantly smaller in the control group (18.73 ± 5.59%) (p < 0.05). Bovine-derived bone graft material containing hydrogel (S1-XB) had a better cellular response and an osteogenic effect similar to Bio-Oss.

Verified
Journal Article
Open access
PDF file
YSYoung-Gun Shin
Young-Gun Shin
WCWon-Tak Cho
Won-Tak Cho
HLHo-Kyung Lim
Ho-Kyung Lim
SHSu-hyun Hwang
Su-hyun Hwang
DDDddd Dddd
Dddd Dddd
JHJung-Bo Huh
Jung-Bo Huh
This prospective study was undertaken to evaluate the clinical usefulness of a newly developed one-piece, screw-free, and micro-locking implant system, which was designed to overcome the shortcomings of the existing implant systems. Thirty-eight patients were recruited and randomly and equally assigned to an experimental group (micro-locking one-piece fixture, MLF; n = 19) or a control group (micro-locking abutment, MLA). Cumulative implant survival rates, marginal bone resorptions, probing depths, plaque indices, bleeding indices, and complications were obtained by using clinical and radiographic findings at 6 months and 12 months after prosthesis placement. Complications that occurred multiple times for single implants were counted. During the 12 month observation period, survival rates were 100% in both groups. No significant intergroup differences were observed for marginal bone resorption, probe depth, or bleeding index. However, mean plaque index was significantly lower in the MLF group at 12 months (p < 0.05). During the 12-month observation period, food impaction (26.3%) was the main complication in the MLF group and screw loosening (5.3%), prosthesis detachment (5.3%), and food impaction (5.3%) were observed in the MLA group. The results of this study suggest that the one-piece micro-locking implant system offers a predictable treatment method.

28 June 2023 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
EBEun-Bin Bae
Eun-Bin Bae
WCWon-Tak Cho
Won-Tak Cho
DPDo-Hyun Park
Do-Hyun Park
SHSu-hyun Hwang
Su-hyun Hwang
SLSo-Hyoun Lee
So-Hyoun Lee
JHJung-Bo Huh
Jung-Bo Huh
Bae EB, et al. J Adv Prosthodont. 2023 Jun;15(3):155-170. https://doi.org/10.4047/jap.2023.15.3.155