Background: Early cancer detection is crucial for improving patient outcomes. Molecular imaging biomarkers offer the potential for non-invasive, early-stage cancer diagnosis. Objectives: To evaluate the effectiveness and accuracy of molecular imaging biomarkers for early cancer detection across various imaging modalities and cancer types. Methods: A comprehensive search of PubMed/MEDLINE, Embase, Web of Science, Cochrane Library, and Scopus was performed, covering the period from January 2010 to December 2023. Eligibility criteria included original research articles published in English on molecular imaging biomarkers for early cancer detection in humans. The risk of bias for included studies was evaluated using the QUADAS-2 tool. The findings were synthesized through narrative synthesis, with quantitative analysis conducted where applicable. Results: In total, 50 studies were included. Positron emission tomography (PET)-based biomarkers showed the highest sensitivity (mean: 89.5%, range: 82–96%) and specificity (mean: 91.2%, range: 85–100%). Novel tracers such as [68Ga]-PSMA for prostate cancer and [18F]-FES for breast cancer demonstrated promising outcomes. Optical imaging techniques showed high specificity in intraoperative settings. Conclusions: Molecular imaging biomarkers show significant potential for improving early cancer detection. Integration into clinical practice could lead to earlier interventions and improved outcomes. Further research is needed to address standardization and cost-effectiveness.
Purpose: Investigate the impact of acquisition time and reconstruction parameters on single‐photon emission computed tomography/computed tomography (SPECT/CT) image quality with the ultimate aim of finding the shortest possible acquisition time for clinical whole‐body SPECT/CT (WB‐SPECT/CT) while maintaining image qualityMethods: The National Electrical Manufacturers Association (NEMA) image quality measurements were performed on a SPECT/CT imaging system using a NEMA International Electrotechnical Commission (IEC) phantom with spherical inserts of varying diameter (10–37 mm), filled with 99mTc in activity sphere‐to‐background concentration ratio of 8.5:1. A gated acquisition was acquired and binned data were summed to simulate acquisitions of 15, 8, and 3 s per projection angle. Images were reconstructed on a Hermes (HERMES Medical Solutions AB, Stockholm, Sweden) workstation using eight subsets and between 4 and 24 iterations of the three‐dimensional (3D) ordered subset expectation maximization (OSEM) algorithm. Reconstructed images were post‐smoothed with 3D Gaussian filter ranging from 0 to 12 mm full‐width at half maximum (FWHM). Contrast recovery, background variability, and contrast‐to‐noise ratio were evaluatedResults: As expected, the spheres were more clearly defined as acquisition time and count statistics improved. The optimal iteration number and Gaussian filter were determined from the contrast recovery convergence and level of noise. Convergence of contrast recovery was observed at eight iterations while 12 iterations yielded stabilized values at all acquisition times. In addition, it was observed that applying 3D Gaussian filter of 8–12 mm FWHM suppressed the noise and mitigated Gibbs artifacts. Background variability was larger for small spheres than larger spheres and the noise decreased when acquisition time became longer. A contrast‐to‐noise ratio >5 was reached for the two smallest spheres of 10 and 13 mm at acquisition times of 8 sConclusion: Optimized reconstruction parameters preserved image quality with reduce acquisition time in present study. This study suggests an optimal protocol for clinical 99mTc SPECT/CT can be reached at 8 s per projection angle, with data reconstructed using 12 iterations and eight subset of the 3D OSEM algorithm and 8 mm Gaussian post‐filter.
Computed Tomography (CT) is vital for diagnosing and monitoring medical conditions. However, increased usage raises concerns about patient radiation exposure. Diagnostic Reference Levels (DRLs) aim to minimize radiation doses in CT imaging. This study examines CT DRLs in India compared to other countries to identify optimization opportunities. A literature review was conducted to gather data from published studies, guidelines, and regulatory authorities. Findings show significant international variations in CT DRLs, with differences up to 50%. In India, DRLs also vary significantly across states. For head CT exams, Indian DRLs are generally 20–30% lower than international standards (27–47 mGy vs. 60 mGy). Conversely, for abdominal CT scans, Indian DRLs are 10–15% higher (12–16 mGy vs. 13 mGy). Factors influencing DRL variations include equipment differences, imaging protocols, patient demographics, and regulatory conditions. Dose-optimization techniques like automatic exposure control and iterative reconstruction can reduce radiation exposure by 25–60% while maintaining image quality. Comparative data highlight best practices, such as the United Kingdom’s 30% reduction in CT doses from 1984 to 1995 via DRL implementation. This study suggests that adopting similar practices in India could reduce radiation doses by 20–40% for common CT procedures, promoting responsible CT usage and minimizing patient exposure.
Objective: To investigate the impact of reduced SPECT acquisition time on reconstructed image quality for diagnostic purposes. Method: Data from five patients referred for a routine bone SPECT/CT using the standard multi-bed SPECT/CT protocol were reviewed. The acquisition time was 900 s using gating technique; SPECT date was resampled into reduced data sets of 480 s, 450 s, 360 s and 180 s acquisition duration per bed position. Each acquisition time was reconstructed using a fixed number of subsets (8 subsets) and 4, 8, 12, and 16 iterations, followed by a post-reconstruction 3D Gaussian filter of 8 mm FWHM. Two Nuclear Medicine physicians analysed all images independently to score image quality, noise and diagnostic confidence based on a pre-defined 4-point scale. Results: Our result showed that the most frequently selected categories for 480 s and 450 s images were good image quality, average noise and fair confidence, particularly at lower iteration numbers 4 and 8. For the shortened acquisition time of 360 s and 180 s, statistical significance was observed in most reconstructed images compared with 900 s. Conclusion: The SPECT/CT can significantly shorten the acquisition time with maintained image quality, noise and diagnostic confidence. Therefore, acquiring data over 480 s and 450 s is feasible for WB-SPECT/CT bone scans to provide an optimal balance between acquisition time and image quality.
Introducing a hybrid imaging approach, such as single-photon emission computerized tomography with X-ray computed tomography (SPECT)/CT, improves diagnostic accuracy and patient management. The ongoing advancement of SPECT hardware and software has resulted in the clinical application of novel approaches. For example, whole-body SPECT/CT (WB-SPECT/CT) studies cover multiple consecutive bed positions, similar to positron emission tomography-computed tomography (PET/CT). WB-SPECT/CT proves to be a helpful tool for evaluating bone metastases (BM), reducing equivocal findings, and enhancing user confidence, displaying effective performance in contrast to planar bone scintigraphy (PBS). Consequently, it is increasingly utilized and might substitute PBS, which leads to new questions and issues concerning the acquisition protocol, patient imaging time, and workflow process. Therefore, this review highlights various aspects of WB-SPECT/CT acquisition protocols that need to be considered to help understand WB-SPECT/CT workflow processes and optimize imaging protocols.