15 June 2025 in Energies
Verified
Journal Article
Open access
PDF file
BYBortecene Yildirim
Bortecene Yildirim
MEMohmmed Ali Mohammed Elgendy
Mohmmed Ali Mohammed Elgendy
ASAndrew Smith
Andrew Smith
Mehmet KulanMehmet Kulan
Mehmet Kulan
BABAHADIR AKBAL
BAHADIR AKBAL
Modular converters offer an effective solution for battery energy storage systems (BESSs) by lowering battery pack voltage levels and enabling additional functionalities, such as state of charge (SoC) and state of health (SoH) balancing, temperature regulation, and improved system reliability. However, conventional modular designs often require numerous additional components, including passive elements, switches, and sensing circuits. This paper proposes a modular multi-port converter (MMPC) BESS that combines energy conversion and battery management functions, leveraging the benefits of both modular and multi-port architectures. The proposed system demonstrates promising scalability and adaptability within the tested voltage and power ranges, with potential for extension to higher voltage and power applications through modular expansion. It also introduces an additional control layer, enhancing flexibility for control optimization and cost-effectiveness while improving reliability by reducing dependency on bypass switches. A prototype utilizing three dual-port converters managing six battery packs was developed. The experimental results confirm that the MMPC-based BESS achieves energy conversion and effectively balances the SoC among battery packs during both charging and discharging, under initial SoC mismatches.

4 September 2020 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
BABAHADIR AKBAL
BAHADIR AKBAL
Cable termination fault (CTF) generally occurs due to increasing of electrical force (EF) and thermal effect (TE) in mixed line. EF increases due to sheath voltage (SV), and TE increases due to harmonic distortion (HD) on cable terminations (CTs). Also, SV and HD increase due to zero‐sequence current (ZC). In the literature, different bonding methods are used to prevent CTF, but these methods are not sufficient to prevent CTF that is based on ZC. In this study, the modified sectional solid bonding (MSSB) is suggested to prevent CTF. The aims of MSSB method are to restrict EF and TE on CT. Thus, MSSB parameters are optimised to restrict SV and HD, but SV and HD on CT should be known for optimisation of MSSB parameters. Thus, SV and HD are forecasted by using adaptive neuro‐fuzzy inference system (Anfis), artificial neural networks (ANNs) and hybrid ANN. Training and forecasting errors of hybrid ANN are less than Anfis and the other ANN methods. Thus, hybrid ANN methods are used as fitness function of optimisation algorithms in MSSB optimisation. When the optimised MSSB method is used for cable bonding, HD and SV on CT are restricted the determined limits to prevent CTF in long mixed line.

19 October 2019 in Neural Computing and Applications
Verified
Journal Article
Closed access
PDF file
BABAHADIR AKBAL
BAHADIR AKBAL

31 December 2020 in Konya Journal of Engineering Sciences
Verified
Journal Article
Closed access
PDF file
SBSerkan Budak
Serkan Budak
BABAHADIR AKBAL
BAHADIR AKBAL
Overhead lines are generally used for electrical energy transmission. Also, XLPE underground cable lines are generally used in the city center and the crowded areas to provide electrical safety, so high voltage underground cable lines are used together with overhead line in the transmission lines, and these lines are called as the mixed lines. The distance protection relays are used to determine the impedance based fault location according to the current and voltage magnitudes in the transmission lines. However, the fault location cannot be correctly detected in mixed transmission lines due to different characteristic impedance per unit length because the characteristic impedance of high voltage cable line is significantly different from overhead line. Thus, determinations of the fault section and location with the distance protection relays are difficult in the mixed transmission lines. In this study, 154 kV overhead transmission line and underground cable line are examined as the mixed transmission line for the distance protection relays. Phase to ground faults are created in the mixed transmission line. overhead line section and underground cable section are simulated by using PSCAD/ EMTDC ™. The short circuit fault images are generated in the distance protection relay for the overhead transmission line and underground cable transmission line faults. The images include the R-X impedance diagram of the fault, and the R-X impedance diagram have been detected by applying image processing steps. Artificial neural network (ANN) and the regression methods are used for prediction of the fault location, and the results of image processing are used as the input parameters for the training process of ANN and the regression methods. The results of ANN and regression methods are compared to select the most suitable method at the end of this study for forecasting of the fault location in transmission lines.

6 December 2019 in Elektronika ir Elektrotechnika
Verified
Journal Article
Open access
PDF file
BABAHADIR AKBAL
BAHADIR AKBAL
Cable termination fault is one of the most important problems for high voltage underground cable lines (HVUCL). Harmonic current (HC) and the sheath current (SC) are causes of cable termination faults of HVUCL. The sheath voltage (SV) of cable increases due to SC and HC also. So, the electroshock risk for human occurs. In this study, cable termination faults are examined for long HVUCL that is connected to electric network with high harmonic distortion rate. In literature, solid bonding (SB) and sectional solid bonding (SSB) methods are used to reduce harmonic distortion rate and SC effect in HVUCL. However, when SB and SSB methods are used for bonding of long HVUCL, harmonic distortion limit and touch voltage limit are exceeded. Therefore, the modified SSB (MSSB) method is developed for bonding of long HVUCL. SV of HVUCL should be known to use MSSB for bonding of long HVUCL. Then SV of HVUCL is forecasted by using artificial neural network and hybrid artificial neural networks (HANN) before the long HVUCL is installed. MSSB parameters should be optimized, so that optimization methods are used for optimization of MSSB and HANN. When MSSB method is used for bonding of long HVUCL, harmonic distortion limit and touch voltage limit are not exceeded under high harmonic distortion conditions.

3 September 2020 in Konya Journal of Engineering Sciences
Verified
Journal Article
Closed access
PDF file
SBSerkan Budak
Serkan Budak
BABAHADIR AKBAL
BAHADIR AKBAL
Elektrik enerjisinin kesintisiz ve kaliteli bir şekilde iletilmesi için, üretim yapıldığı noktadan tüketimolan noktaya kadar kontrol edilmesi gerekmektedir. Dolayısıyla üretimden tüketime kadar her aşamadailetim ve dağıtım hatlarında koruma yapılması şarttır. Elektrik tesislerinde koruma rölelerinin temelgörevi, sistemde meydana gelen kısa devrelerde arızalı olan bölgenin mümkün olan en kısa sürede devredışı etmektir. Sistemin en önemli parçası olan enerji iletim hatları ve bu hatları koruyan mesafe korumarölelerine bu konuda çok önemli görevler düşmektedir. Hızlı ve verimli çalışmalar yapmak için doğrubir hata yeri tespit tekniği gereklidir. İletim hatlarında transformatör nötr nokta topraklaması bir güçsisteminin tek faz – toprak kısa devre arızası sırasında oluşan sıfır bileşen akımı mesafe koruma rölesininçalışmasını etkilemektedir. Topraklama sistemi ve koruma sistemleri arasındaki ilişki göz önünealındığında, uygun bir topraklama seçimi yapılmalıdır. İletim hatlarında farklı topraklama sistemlerindekısa devre arızalarının yerinin doğru bir şekilde belirlenebilmesi için yapay sinir ağı (YSA) kullanılmıştır.YSA’nın performansını test etmek için destek vektör makineleri (DVM) ile karşılaştırılmıştır. İletim hattımodeli PSCAD ™ / EMTDC ™ benzetim programında oluşturulup YSA için gerekli veriler eldeedilmiştir. Farklı topraklama sistemlerinde oluşturulan kısa devre arızalarındaki mesafe korumarölesinin R-X empedans diyagramının empedans değişiminin görüntüsü kayıt altına alınarak veri setlerioluşturulmuştur. Görüntülerde ilgili odak noktaları özellik çıkarım ve görüntü işleme tekniklerikullanılarak farklı YSA modellerine giriş olarak verilmiş ve en iyi arıza yeri tahmini veren YSA modeliseçilmiştir.