Gadang Priyotomo

Dr. Gadang Priyotomo

National Research and Innovation Agency, South Tangerang, Indonesia

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2021 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
AKAgus Paul Setiawan Kaban
Agus Paul Setiawan Kaban
ARAga Ridhova
Aga Ridhova
GPGadang Priyotomo
Gadang Priyotomo
BEBerna Elya
Berna Elya
AMAhmad Maksum
Ahmad Maksum
JSJohny Wahyuadi Soedarsono
Johny Wahyuadi Soedarsono
This work covers the effectiveness of the White tea extract as a green corrosion inhibitor and is correlated to the strength and stability bonding between the phenolic molecule and the Fe atoms in mild steel and how this interaction can be studied by altering the concentration and temperature. White tea has received considerable attention due to its capability as a corrosion inhibitor and has been extensively studied using electrochemical techniques. However, accurate and systematic functional group identification and surface modification have been missing. Our study sought to demonstrate the quantitative measurement of electrochemical impedance spectroscopy (EIS) complemented by the FTIR (Fourier transform infrared spectroscopy), Total Phenolic Test, and Raman Spectroscopy. The SEM (Scanning Electronic Microscope)/EDX (Energy-Dispersive X-Ray Spectroscopy), and AFM (Atomic Force Microscope) were used to study the surface modification. The EIS results show that the optimum inhibition efficiency was 96 % in a solution of 80 ppm at 60 °C. Acetone 70 % was used to extract White tea and gives 14.17±0.25 % phenolic compound. Spectroscopic studies show -OH, Aromatic C=C, C=O and C-O-C become major contributors in the adsorption process and are found on the surface of metals as corrosion protection. Meanwhile, the thermodynamic calculation shows the White tea was adsorbed chemically. The nearness of R2 to 1 shows the adsorption agrees with the Langmuir adsorption isotherm. Eventually, the surface modification revealed that phenol molecules are responsible to reduce the corrosion rate at 16.38×10-3 mpy. Our results are expected to provide a guideline for future research in White tea as a green corrosion inhibitor

Verified
Journal Article
Open access
PDF file
Agung IswadiAgung Iswadi
Agung Iswadi
JPJoanne S. Porter
Joanne S. Porter
MBMichael Bell
Michael Bell
LGLeuserina Garniati
Leuserina Garniati
RHRobert E. Harris
Robert E. Harris
GPGadang Priyotomo
Gadang Priyotomo
Marine renewable energy holds strategic potential in Indonesia, not only to meet the target of renewable energy share in the national energy mix but also to provide equal access to clean energy throughout the archipelago. Marine energy in Indonesia is still in the early phase of development, which mainly focusses on resources assessment and power generation through technology prototype testing. Based on a review of available literature, it is found that specific research on the effects of biofouling on material durability of marine energy infrastructure in Indonesia has yet to be addressed. In this study, a matrix that identifies and predicts key fouling organisms and their possible risks on marine renewable energy infrastructure in tropical waters of Indonesia is developed by analysing previous findings in temperate and subtropical waters. Based on the matrix developed, calcareous polychaetes (Serpulidae), barnacles (Amphibalanus spp.), and bivalves (Perna viridis) are among possible key fouling organisms that might pose risks to marine energy infrastructure in Indonesia, such as by adding weight and drag and causing corrosion. Further studies and detailed and statistically robust analysis of the biofouling and its impacts are needed to support the development of the technological performance of marine renewable energy in Indonesia.

31 December 2022 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
RRRini Riastuti
Rini Riastuti
GMGiannisa Mashanafie
Giannisa Mashanafie
VRVika Rizkia
Vika Rizkia
AMAhmad Maksum
Ahmad Maksum
SPSiska Prifiharni
Siska Prifiharni
JSJohny Soedarsono
Johny Soedarsono
Corrosion in API 5L steel under 1M HCl is a common issue; hence, creating a more effective and naturally-based inhibitor is critical. In this research, Syzygium Cumini leaf extract (SCLE) was used as a new green corrosion inhibitor under acidic conditions. The inhibition properties of the novel cumini extract were thoroughly characterized using potentiodynamic polarization (PDP), electrochemical impedance spectroscopy (EIS), Fourier-transform infrared spectroscopy (FTIR), and atomic force microscope (AFM). The results show that the cumini inhibitor has excellent corrosion inhibition with 93 % inhibition efficiency. The adsorption behavior of the inhibitor follows the Langmuir Adsorption Isotherm due to the nearness of R2 to unity. The potentiodynamic and electrochemical measurements demonstrate the mixed type of corrosion inhibitor. Thermodynamic calculation of ΔGads is – 18.41 kJ mol-1 showing the physical adsorption process between the inhibitor and metals. Further inspection of ΔHads at ‒58.93 kJ mol-1 considers releasing energy during adsorption. The FTIR results agree with the increased growth of passive layers due to the adsorption of polyphenol and flavonoids on metals. Remarkably, the adsorption peak at 3266.59 cm-1 corresponds to the adsorption of –OH. The peak at 1612.56 and 1698.4 cm-1 is attributed to C=C and C=O functional groups. The above functional groups serve as adsorption centers to reduce the corrosion effect. The surface treatment of AFM indicated a good relationship with the functional group characterization and confirmed the significant corrosion rate reduction. This work can be used as a benchmark to develop a natural plant as a corrosion inhibitor.

1 September 2018 in Ceramics International
Verified
Journal Article
Closed access
AAAmun Amri
Amun Amri
AFAhmad Fadli
Ahmad Fadli
ZJZhong-Tao Jiang
Zhong-Tao Jiang
CYChun Yin
Chun Yin
Md Mahbubur RahmanMd Mahbubur Rahman
Md Mahbubur Rahman
NFNeni Frimayanti
Neni Frimayanti

27 August 2021 in Walailak Journal of Science and Technology (WJST)
Verified
Journal Article
Open access
PDF file
GPGadang Priyotomo
Gadang Priyotomo
SPSiska Prifiharni
Siska Prifiharni
LNLutviasari Nuraini
Lutviasari Nuraini
JTJoko Triwardono
Joko Triwardono
ARAhmad Royani
Ahmad Royani
HGHadi Gunawan
Hadi Gunawan
The investigation of atmospheric corrosion of mild carbon steel as representative of offshore infrastructure has been carried out in the marine tropical of Pelabuhan Ratu, West Java, Indonesia. They are exposed up to 76 days of periods, and their corrosion rates are determined according to ASTM G1-03. The surface morphology, the elemental compositions and compounds were observed using a scanning electron microscope (SEM), energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD), respectively. The environmental parameters of the test site are monitored during exposure, such as air temperature, relative humidity (RH), airborne salinity and dew temperature. Based on the results, the corrosion rates of steels were 2.79 and 2.8 mpy within the 27 and 76 days exposures, respectively. The presence of chloride deposition on the surface of steel can increase the severity of corrosion. Moreover, the detrimental effect of chloride was observed in rust product, which was covered by an oxygen element. The main phases of rust products present were magnetite (Fe3O4) and hematite (α-Fe2O3.H2O). Several cracks were observed in the rust layer, which tended to exfoliate and lose adherence and protectiveness from further corrosion attack. HIGHLIGHTS GRAPHICAL ABSTRACT


30 October 2020 in Jurnal Teknik Mesin Cakram
Verified
Journal Article
Open access
PDF file
GPGadang Priyotomo
Gadang Priyotomo
Masalah korosi merupakan salah satu pertimbangan biaya pemeliharaan dalam proses produksi industri minyak dan gas bumi, petrokimia dan geothermal. Salah satu metode mitigasi korosi adalah proses pelapisan polimer atau cat. Walaupun struktur di lapis oleh cat, proses korosi terjadi karena preparasi permukaan yang tidak benar. Proses deteksi dini korosi dibawah lapisan cat bisa salah satu kandidat untuk mengurangi kerusakan lebih lanjut. Material senyawa cerdik adalah phenolphthalein (PP) diperlukan sebagai indikator terjadinya korosi. Konsentrasi senyawa PP divariasikan dengan sebesar 0,01% ; 0,1 % dan 1% yang diimbuhkan ke lapisan berbasis akrilik. Pengujian perfoma lapisan cat melalui pengujian kabut garam (ASTM B117-97) selama 240 jam. Metode visualisasi secara makro dilakukan untuk melihat kerusakan cat. Perfoma senyawa PP pada cat dengan konsentrasi 0,01% dan 1% memberikan indikasi bercak warna jingga di waktu ekspos 24 jam. Reaksi oksidasi dan reduksi (elektrokimia) berlangsung pada daerah antar muka lapisan cat dan substrak baja melalui visualisasi warna jingga.