Tomasz Grzywacz

Tomasz Grzywacz

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2020 in Molecules
Verified
Journal Article
Open access
PDF file
JLJérémie Loulier
Jérémie Loulier
François LefortFrançois Lefort
François Lefort
MSMarcin Stocki
Marcin Stocki
MAMonika Asztemborska
Monika Asztemborska
RSRafal Szmigielski
Rafal Szmigielski
JNJustyna Nowakowska
Justyna Nowakowska
Fungi and oomycetes release volatiles into their environment which could be used for olfactory detection and identification of these organisms by electronic-nose (e-nose). The aim of this study was to survey volatile compound emission using an e-nose device and to identify released molecules through solid phase microextraction–gas chromatography/mass spectrometry (SPME–GC/MS) analysis to ultimately develop a detection system for fungi and fungi-like organisms. To this end, cultures of eight fungi (Armillaria gallica, Armillaria ostoyae, Fusarium avenaceum, Fusarium culmorum, Fusarium oxysporum, Fusarium poae, Rhizoctonia solani, Trichoderma asperellum) and four oomycetes (Phytophthora cactorum, P. cinnamomi, P. plurivora, P. ramorum) were tested with the e-nose system and investigated by means of SPME-GC/MS. Strains of F. poae, R. solani and T. asperellum appeared to be the most odoriferous. All investigated fungal species (except R. solani) produced sesquiterpenes in variable amounts, in contrast to the tested oomycetes strains. Other molecules such as aliphatic hydrocarbons, alcohols, aldehydes, esters and benzene derivatives were found in all samples. The results suggested that the major differences between respective VOC emission ranges of the tested species lie in sesquiterpene production, with fungi emitting some while oomycetes released none or smaller amounts of such molecules. Our e-nose system could discriminate between the odors emitted by P. ramorum, F. poae, T. asperellum and R. solani, which accounted for over 88% of the PCA variance. These preliminary results of fungal and oomycete detection make the e-nose device suitable for further sensor design as a potential tool for forest managers, other plant managers, as well as regulatory agencies such as quarantine services.

23 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Piotr BorowikPiotr Borowik
Piotr Borowik
LALeszek Adamowicz
Leszek Adamowicz
RTRafał Tarakowski
Rafał Tarakowski
KSKrzysztof Siwek
Krzysztof Siwek
TGTomasz Grzywacz
Tomasz Grzywacz
Recent advances in the field of electronic noses (e-noses) have led to new developments in both sensors and feature extraction as well as data processing techniques, providing an increased amount of information. Therefore, feature selection has become essential in the development of e-nose applications. Sophisticated computation techniques can be applied for solving the old problem of sensor number optimization and feature selections. In this way, one can find an optimal application-specific sensor array and reduce the potential cost associated with designing new e-nose devices. In this paper, we examine a procedure to extract and select modeling features for optimal e-nose performance. The usefulness of this approach is demonstrated in detail. We calculated the model’s performance using cross-validation with the standard leave-one-group-out and group shuffle validation methods. Our analysis of wine spoilage data from the sensor array shows when a transient sensor response is considered, both from gas adsorption and desorption phases, it is possible to obtain a reasonable level of odor detection even with data coming from a single sensor. This requires adequate extraction of modeling features and then selection of features used in the final model.

5 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Piotr BorowikPiotr Borowik
Piotr Borowik
TGTomasz Grzywacz
Tomasz Grzywacz
RTRafał Tarakowski
Rafał Tarakowski
Miłosz TkaczykMiłosz Tkaczyk
Miłosz Tkaczyk
SŚSławomir Ślusarski
Sławomir Ślusarski
Tomasz Krzysztof OszakoTomasz Krzysztof Oszako
Tomasz Krzysztof Oszako
In the construction of electronic nose devices, two groups of measurement setups could be distinguished when we take into account the design of electronic nose chambers. The simpler one consists of placing the sensors directly in the environment of the measured gas, which has an important advantage, in that the composition of the gas is not changed as the gas is not diluted. However, that has an important drawback in that it is difficult to clean sensors between measurement cycles. The second, more advanced construction, contains a pneumatic system transporting the gas inside a specially designed sensor chamber. A new design of an electronic nose gas sensor chamber is proposed, which consists of a sensor chamber with a sliding chamber shutter, equipped with a simple pneumatic system for cleaning the air. The proposal combines the advantages of both approaches to the sensor chamber designs. The sensors can be effectively cleared by the flow of clean air, while the measurements are performed in the open state when the sensors are directly exposed to the measured gas. Airflow simulations were performed to confirm the efficiency of clean air transport used for sensors’ cleaning. The demonstrated electronic nose applies eight Figaro Co. MOS TGS series sensors, in which a transient response caused by a change of the exposition to measured gas, and change of heater voltage, was collected. The new electronic nose was tested as applied to the differentiation between the samples of Ciboria batschiana fungi, which is one of the most harmful pathogens of stored acorns. The samples with various coverage, thus various concentrations of the studied odor, were measured. The tested device demonstrated low noise and a good level of repetition of the measurements, with stable results during several hours of repetitive measurements during an experiment lasting five consecutive days. The obtained data allowed complete differentiation between healthy and infected samples.

1 September 2017
Verified
Conference Paper
Closed access
WBWieslaw Brociek
Wieslaw Brociek
TGTomasz Grzywacz
Tomasz Grzywacz
RWRobert Wilanowicz
Robert Wilanowicz
The paper presents the results of the analysis of voltage and current distortions of the power system containing nonlinear load at changing location. The calculations are done for the power system consisted of overhead line 110kV, transformer station 110/15kV, overhead line 15kV and transformer station 15/0.4kV. Simulations were performed in the Microcap environment.

1 December 2014 in Metrology and Measurement Systems
Verified
Journal Article
Open access
SOStanislaw Osowski
Stanislaw Osowski
KSKrzysztof Siwek
Krzysztof Siwek
TGTomasz Grzywacz
Tomasz Grzywacz
KBK. Brudzewski
K. Brudzewski
The paper presents application of differential electronic nose in the dynamic (on-line) volatile measurement. First we compare the classical nose employing only one sensor array and its extension in the differential form containing two sensor arrays working in differential mode. We show that differential nose performs better at changing environmental conditions, especially the temperature, and well performs in the dynamic mode of operation. We show its application in recognition of different brands of tobacco

20 May 2008 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
TGTomasz Grzywacz
Tomasz Grzywacz
JSJan Sikora
Jan Sikora
SWStefan Wojtowicz
Stefan Wojtowicz
Diffuse optical tomography (DOT) is an emerging functional medical imaging modality with aims to recover the optical properties of biological tissue. The forward problem of the light propagation of DOT can be modelled in the frequency domain as a diffusion equation with Robin boundary conditions. In the case of multilayered geometries with piecewise constant parameters, the forward problem is equivalent to a set of coupled Helmholtz equations. In this paper we present a solution for the multilayered diffuse light propagation for a three-layer concentric sphere model using a series expansion method and for a general layered geometry using the boundary element method.