Ning Wen

Dr. Ning Wen


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NWNing Wen
Ning Wen
SYSHEN Yu
SHEN Yu
YWYa Wen
Ya Wen
EWErpeng Wang
Erpeng Wang
JYJiyong Yao
Jiyong Yao
QPQin-Jun Peng
Qin-Jun Peng
We experimentally demonstrate a stable and compact high pulse energy mid-infrared (MIR) 6.45 μm laser, which is produced by an optical parametric oscillator (OPO) based on the non-oxide BaGa4Se7 (BGSe) nonlinear crystal pumped by 1064 nm Nd:YAG laser oscillator. With optimizing the parameters of the OPO system, a record high idler energy of 6.76 mJ at 6.45 μm was obtained with 18.85 ns of pulse duration (FWHM) at the repetition rate of 10 Hz under 93.5 mJ of pump energy, corresponding to an optical-to-optical conversion efficiency up to 7.23% from 1064 nm to 6.45 μm. The experimental results were in close approximation with the theoretical calculations. To date, it is both the highest MIR pulse energy and the highest conversion efficiency at 6.45 μm for any 1 μm pumped OPOs. Further, excellent output energy stability is demonstrated, with an energy fluctuation of less than ±0.5% over 165 min. Such a laser is interesting for both scientific and medical applications, including, for instance, for trace gas analysis and tissue ablation.

1 July 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SYSHEN Yu
SHEN Yu
NWNing Wen
Ning Wen
CLChunxiao Li
Chunxiao Li
NZNan Zong
Nan Zong
JYJiyong Yao
Jiyong Yao
DCDafu Cui
Dafu Cui
This paper presents a high pulse energy, narrow linewidth, mid-infrared (MIR) laser at 6.45 μm, based on a BaGa4Se7 (BGSe) crystal optical parametric oscillator (OPO) pumped by 1.064 μm laser. The maximum pulse energy at 6.45 μm was up to 1.23 mJ, with a pulse width of 24.3 ns and repetition rate of 10 Hz, corresponding to an optical–optical conversion efficiency of 2.1%, from pump light 1.064 μm to idler light 6.45 μm. The idler light linewidth was about 6.8 nm. Meanwhile, we accurately calculated the OPO phase-matching condition at BGSe crystal pumped by 1.064 μm laser, and a numerical simulation system was performed to analyze the input–output characteristics at 6.45 μm, as well as the effect of crystal length on the conversion efficiency. Good agreement was found between measurement and simulation. To the best of our knowledge, this is the highest pulse energy at 6.45 μm, with the narrowest linewidth for any all-solid-state MIR ns laser in BGSe-OPO pumped by simple 1.064 μm oscillator. This simple and compact 6.45 μm OPO system, with high pulse energy and narrow linewidth, can meet the requirements for tissue cutting and improve tissue ablation accuracy.