A pulse width adjustable 1064 nm -switched cavity dumped laser was realized for the first time, to the best of our knowledge, by rotating an intracavity quarter-wave plate (QWP) and a Pockels cell (PC). The pulse width adjustment range was 4.8–7.8 ns with a constant output power of 3.6 W, and it reached 4.8–13.5 ns for a lower output power of 1.3 W. The pulse width was dependent mostly on the rotating angle of the QWP and PC, but independent of the gain and pulse repetition rate.
We experimentally demonstrate a stable and compact high pulse energy mid-infrared (MIR) 6.45 μm laser, which is produced by an optical parametric oscillator (OPO) based on the non-oxide BaGa4Se7 (BGSe) nonlinear crystal pumped by 1064 nm Nd:YAG laser oscillator. With optimizing the parameters of the OPO system, a record high idler energy of 6.76 mJ at 6.45 μm was obtained with 18.85 ns of pulse duration (FWHM) at the repetition rate of 10 Hz under 93.5 mJ of pump energy, corresponding to an optical-to-optical conversion efficiency up to 7.23% from 1064 nm to 6.45 μm. The experimental results were in close approximation with the theoretical calculations. To date, it is both the highest MIR pulse energy and the highest conversion efficiency at 6.45 μm for any 1 μm pumped OPOs. Further, excellent output energy stability is demonstrated, with an energy fluctuation of less than ±0.5% over 165 min. Such a laser is interesting for both scientific and medical applications, including, for instance, for trace gas analysis and tissue ablation.
A several-kilowatt level laser at 946 nm is demonstrated in a cryogenically cooled diode-pumped Nd:YAG slab system. The oscillator realizes the record of the output power of 2.85 kW in a compact cavity with the homemade cryogenically cooled Nd:YAG crystal slab. The pulse repetition rate and pulse width of the laser are 400 Hz and 200 µs, respectively, and the center wavelength under full power is 946.2 nm with a bandwidth of about 0.5 nm. The absorption linewidth at 808 nm is a little narrowed and blue shifts at the cryogenic temperature, while the cooling temperature decreases from 300 to 77 K. The measured thermal conductivity increases from 10 to 70 W/mˑK, and the thermal expansion coefficient decreases from 7.5*10−6 to 1.5*10−6/K. These results could guide us in simulating the temperature gradient and thermal-induced stress distributions in the crystal slab.
A theoretical model, based on the classical Pennes’ bioheat theory, incorporating various boundary conditions, was established and compared to analyze the influence of the latent heat of vaporization via simulation. The aim was to elucidate the extent of its influence. The thermal damage rate, governed by the vaporization heat of biological tissue, is introduced as a key factor. Functional relationships between temperature and incident laser power, spatial position, and time are derived from the classical Pennes’ bioheat equation. According to the theoretical model, numerical simulations and experimental validations are conducted using Comsol Multiphysics 6.0, considering the tissue latent heat of vaporization. The model incorporating the latent heat of vaporization proved more suitable for analyzing the interactions between laser and biological tissue, evident from the degree of fit between simulated and experimental data. The minimum deviations between theoretical and experimental observations were determined to be 2.43% and 5.11% in temperature and thermal damage, respectively. Furthermore, this model can be extended to facilitate the theoretical analysis of the impact of vaporization heat from different primary tissue components on laser-tissue interaction.
This paper presents a high pulse energy, narrow linewidth, mid-infrared (MIR) laser at 6.45 μm, based on a BaGa4Se7 (BGSe) crystal optical parametric oscillator (OPO) pumped by 1.064 μm laser. The maximum pulse energy at 6.45 μm was up to 1.23 mJ, with a pulse width of 24.3 ns and repetition rate of 10 Hz, corresponding to an optical–optical conversion efficiency of 2.1%, from pump light 1.064 μm to idler light 6.45 μm. The idler light linewidth was about 6.8 nm. Meanwhile, we accurately calculated the OPO phase-matching condition at BGSe crystal pumped by 1.064 μm laser, and a numerical simulation system was performed to analyze the input–output characteristics at 6.45 μm, as well as the effect of crystal length on the conversion efficiency. Good agreement was found between measurement and simulation. To the best of our knowledge, this is the highest pulse energy at 6.45 μm, with the narrowest linewidth for any all-solid-state MIR ns laser in BGSe-OPO pumped by simple 1.064 μm oscillator. This simple and compact 6.45 μm OPO system, with high pulse energy and narrow linewidth, can meet the requirements for tissue cutting and improve tissue ablation accuracy.
11 September 2024 in IEEE Photonics Technology Letters
Powerful and compact coherent mid-infrared radiation source is crucial for a vast number of applications. A widely tunable 3- $15~\mu $ m optical parametric amplifier with BaGa2GeSe6 crystal pumped by a picosecond mode-locked 1064 nm laser was demonstrated for the first time. Type-I produced a maximum energy of $377~\mu $ J at $5.2~\mu $ m, while type-II achieved a maximum energy of $294~\mu $ J at $6.7~\mu $ m under the incident pump energy of 11.8 mJ, corresponding to the pump-to-idler energy efficiency of 3.2% and 2.5%, respectively. Furthermore, the corresponding phase-matching angles for 3– $15~\mu $ m were measured experimentally. Moreover, the conversion efficiency, typical pulse temporal shapes and beam spatial profiles of idler were calculated based on a BaGa2GeSe6-OPA numerical model. The results indicate the potential of BaGa2GeSe6 pumped at 1064 nm for realizing high-efficiency and high-energy mid-infrared laser radiation.