Philipp Messer-Hannemann

Dr. Philipp Messer-Hannemann

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
ASAlan Leon Sinanovic
Alan Leon Sinanovic
PMPhilipp Messer-Hannemann
Philipp Messer-Hannemann
MSMariam Samadi
Mariam Samadi
Falk SchwendickeFalk Schwendicke
Falk Schwendicke
SESusanne Effenberger
Susanne Effenberger
Resin infiltration is an effective method to mask vestibular white spots. If needed, external bleaching is usually recommended before infiltration, whilst in clinical practice, this sequence may not always be feasible. This in vitro study evaluated the effect of bleaching after resin infiltration regarding surface roughness and color using bovine incisors. Unlike for the untreated specimens (control, n = 25), artificial caries lesions were created within the test group (n = 25) using a demineralization solution at 37 °C for five days (pH = 4.95). The lesions were subsequently infiltrated using a resin infiltrant (Icon, DMG, Hamburg, Germany), followed by polishing. Afterwards, all specimens were bleached with a 10% carbamide peroxide gel (Opalescence, Ultradent, South Jordan, UT, USA) for 8 h/day over a ten-day period. Between bleaching treatments, specimens were stored in an opaque container with moistened paper tissues at 37 °C. Surface roughness was measured using a profilometer, and color in the L*a*b* space was assessed spectrophotometrically before and after bleaching. Bleaching increased the L*-values of both infiltrated (mean ± SD; ΔL* = 3.52 ± 1.98) and untreated (control) specimens (ΔL* = 3.53 ± 2.30) without any significant difference between the groups (p = 0.983). Bleaching also induced a significant increase in the mean surface roughness of both infiltrated (p < 0.001) and untreated (p = 0.0134) teeth. In terms of clinical relevance; it can be concluded that bleaching resin-infiltrated enamel is as effective as bleaching sound enamel.

8 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
PMPhilipp Messer-Hannemann
Philipp Messer-Hannemann
MSMariam Samadi
Mariam Samadi
HBHenrik Böttcher
Henrik Böttcher
SDSebastian Duy
Sebastian Duy
DDDaniela Duy
Daniela Duy
SESusanne Effenberger
Susanne Effenberger
The aim of this study was the development of a test regime to determine the wear resistance and predict the clinical performance of conventional glass ionomer cement (GIC) restorations in Class I tooth cavities. Cavities were prepared in excised human teeth and restored using three conventional glass ionomer restorative materials: DeltaFil, Fuji IX GP and Ketac Universal. The restored teeth were mechanically and thermally stressed using a chewing simulator with a maximum number of 1,200,000 load cycles. Besides determining the number of cycles achieved, the abrasion volume after termination of the chewing simulation was calculated using µCT images. All teeth restored with DeltaFil reached 1,200,000 cycles without any restoration failure. Only 37.5% of the restorations each with Ketac Universal and Fuji IX GP were able to achieve the maximum cycle number. A significant lower abrasion volume for restorations with DeltaFil compared to Ketac Universal (p = 0.0099) and Fuji IX GP (p = 0.0005) was found. Laboratory chewing simulations are a useful tool to study basic wear mechanisms in a controlled setting with in-vivo related parameters. DeltaFil shows an improved wear resistance compared to other conventional GICs, indicating the high potential of this material for long-lasting Class I restorations.

1 October 2019 in Clinical Biomechanics
Verified
Journal Article
Closed access
PMPhilipp Messer-Hannemann
Philipp Messer-Hannemann
GCGraeme M. Campbell
Graeme M. Campbell
MMMichael M. Morlock
Michael M. Morlock

27 December 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
PMPhilipp Messer-Hannemann
Philipp Messer-Hannemann
MWMax Wienhold
Max Wienhold
HEHoda Esbak
Hoda Esbak
ABAlexander Brunner
Alexander Brunner
ASAndreas Schönebaum
Andreas Schönebaum
SESusanne Effenberger
Susanne Effenberger
Background/Objectives: Diphenyl (2,4,6-trimethylbenzoyl) phosphine oxide (TPO) is widely used in the dental industry as a photoinitiator for resin-based materials, while its use may be further limited given its toxicological risks. The aim of this study was, therefore, to analyze the residual TPO content of 3D-printed resin-based dental splint materials. Methods: Six resin-based splint materials were analyzed: LuxaPrint Ortho Plus (DMG), FREEPRINT splint 2.0 (Detax), optiprint splint (Dentona), KeySplint Soft (KeyPrint), FREEPRINT ortho (Detax), V-Print splint comfort (Voco). Grid-shaped specimens were fabricated using the recommended workflow of each manufacturer (n = 18). TPO extraction was conducted using a maximum of eight extraction cycles of 72 h at a temperature of 37 °C until no more TPO eluates were detected by high-performance liquid chromatography (HPLC). The margin of safety (MoS) was calculated as the ratio between the Derived No-Effect Level (DNEL) and the estimated exposure based on the amount of TPO extracted. Results: The total amount of extracted TPO was the lowest for LuxaPrint Ortho Plus (Mean ± SD; 44.0 ± 17.1 ng/mL), followed by optiprint splint (80.6 ± 21.1 ng/mL), FREEPRINT splint 2.0 (127.4 ± 25.3 ng/mL), FREEPRINT ortho (2813.2 ± 348.0 ng/mL), V-Print splint comfort (33,424.6 ± 8357.9 ng/mL) and KeySplint Soft (42,083.5 ± 3175.2 ng/mL). For all tested materials, the calculated MoS was above the critical value of 1, demonstrating toxicological safety in the cured, clinically relevant state. Conclusions: Large differences in the residual TPO content were observed between the materials. Although the TPO content in the uncured state may exceed toxicological safety limits, appropriate curing of the investigated materials resulted in a significant reduction in TPO elution and, thus, in products with a very low toxicological risk for the patient.

19 May 2020 in Medical Engineering & Physics
Verified
Journal Article
Closed access
PMPhilipp Messer-Hannemann
Philipp Messer-Hannemann
HWHannah Weyer
Hannah Weyer
GCGraeme M Campbell
Graeme M Campbell
MMMichael M Morlock
Michael M Morlock
Deformation of an acetabular cup implant during cementless implantation is indicative of the radial compressive forces, and such of the initial implant fixation strength. Stress relaxation in the surrounding bone tissue following implantation could reduce the deformation of the cup and thus primary implant fixation. The aim of this study was therefore to determine the early shape change of the implanted cup immediately after implantation with different press-fit levels and whether recording the force during cup impaction can be used to estimate initial cup fixation. Cup implantations into porcine acetabulae (n=10) were performed using a drop tower. The force induced by the drop weight and cup seating after each impact was recorded. Deformation of the implanted cup was determined with strain gauges over a period of 10min. Lever-out torques were measured to assess the initial fixation strength. Stress relaxation in the bone caused a reduction in cup deformation of 13.52±4.06% after 1min and 29.34±5.11% after 10min. The fixation strength increased with a higher force magnitude during impaction (Rs2=0.810, p=0.037). Reduction of the radial compressive forces due to stress relaxation of the surrounding bone should be considered during press-fit cup implantation in order to compensate for the reduced fixation strength over time. In addition, recording the implantation force could help to estimate initial fixation strength.

Verified
Journal Article
Open access
PDF file
PMPhilipp Messer-Hannemann
Philipp Messer-Hannemann
HBHenrik Böttcher
Henrik Böttcher
SHSven Henning
Sven Henning
Falk SchwendickeFalk Schwendicke
Falk Schwendicke
SESusanne Effenberger
Susanne Effenberger
The objective of this study was to transfer the concept of ductile particle reinforcement to restorative dentistry and to introduce an innovative glass ionomer material that is based on the dispersion of PEG-PU micelles. It was hypothesized that reinforcing a conventional glass ionomer in this way increases the flexural strength and fracture toughness of the material. Flexural strength and fracture toughness tests were performed with the novel reinforced and a control glass ionomer material (DMG, Hamburg, Germany) to investigate the influence of the dispersed micelles on the mechanical performance. Transmission electron microscopy was used to identify the dispersed micelles. Fracture toughness and flexural strength were measured in a 3-point-bending setup using a universal testing machine. Before performing both tests, the specimens were stored in water at 37 °C for 23 h. The fracture toughness (MPa∙m0.5) of the novel glass ionomer material (median: 0.92, IQR: 0.89–0.94) was significantly higher than that of the control material (0.77, 0.75–0.86, p = 0.0078). Significant differences were also found in the flexural strength (MPa) between the reinforced (49.7, 45.2–57.8) and control material (41.8, 40.6–43.5, p = 0.0011). Reinforcing a conventional glass ionomer with PEG-PU micelles improved the mechanical properties and may expand clinical applicability of this material class in restorative dentistry.