Hemorrhage is a detrimental event present in traumatic injury, surgery, and disorders of bleeding that can become life-threatening if not properly managed. Moreover, uncontrolled bleeding can complicate surgical interventions, altering the outcome of surgical procedures. Therefore, to reduce the risk of complications and decrease the risk of morbidity and mortality associated with hemorrhage, it is necessary to use an effective hemostatic agent that ensures the immediate control of bleeding. In recent years, there have been increasingly rapid advances in developing a novel generation of biomaterials with hemostatic properties. Nowadays, a wide array of topical hemostatic agents is available, including chitosan-based biomaterials that have shown outstanding properties such as antibacterial, antifungal, hemostatic, and analgesic activity in addition to their biocompatibility, biodegradability, and wound-healing effects. This review provides an analysis of chitosan-based hemostatic biomaterials and discusses the progress made in their performance, mechanism of action, efficacy, cost, and safety in recent years.
Additive manufacturing (AM) is an important technology that led to a high evolution in the manufacture of personalized implants adapted to the anatomical requirements of patients. Due to a worldwide graft shortage, synthetic scaffolds must be developed. Regarding this aspect, biodegradable materials such as magnesium and its alloys are a possible solution because the second surgery for implant removal is eliminated. Magnesium (Mg) exhibits mechanical properties, which are similar to human bone, biodegradability in human fluids, high biocompatibility, and increased ability to stimulate new bone formation. A current research trend consists of Mg-based scaffold design and manufacture using AM technologies. This review presents the importance of biodegradable implants in treating bone defects, the most used AM methods to produce Mg scaffolds based on powder metallurgy, AM-manufactured implants properties, and in vitro and in vivo analysis. Scaffold properties such as biodegradation, densification, mechanical properties, microstructure, and biocompatibility are presented with examples extracted from the recent literature. The challenges for AM-produced Mg implants by taking into account the available literature are also discussed.
(1) Background: During IVF (in vitro fertilization), a proper endometrium thickness is one of the most difficult parameters to achieve and one of the most important prognostic factors of the success rate. One major problem is the high cancelation percentage in frozen embryo transfer cycles. The focus on the adjuvant methods for improving endometrium thickness is an on-going subject of interest. (2) Methods: This prospective single-arm self-control study was conducted in an IVF centre in Oradea, Romania. The patients were divided into two groups. The control group included 51 patients with at least one attempt to transfer a good-quality blastocyst, but the endometrial thickness did not surpass 7 mm under standard endometrial preparation protocol with oestradiol and with adjuvant therapy (other than PRP, such as aspirin, vitamin C, and vitamin E), and the study group included the same 51 patients that had the embryo transfer performed under the same standard endometrial preparation protocol with oestradiol preparation protocol and intrauterine PRP infusion. (3) Results: In our study, the PRP treatment had a positive impact on the parameters that were followed for the evaluation of the success rate of the embryo transfer procedure. The endometrial thickness (an increase in endometrial thickness by 0.6 mm after PRP treatment with p = 0.0001) and the clinical pregnancy rate (having a MD ± SD of 0 ± 0.38 before PRP treatment and with an increase to 0.5 ± 0.1 after the PRP treatment, p = 0.0004) were statistically significant (4) Conclusions: PRP has a positive effect in promoting endometrial proliferation, improving embryo implantation rate and clinical pregnancy rate for women with thin endometrium.
(1) Background: Intrauterine insemination (IUI) is considered a first-line procedure for infertile or hypo-fertile couples among assisted reproductive techniques. In our retrospective study, we identified variables associated with a successful IUI and the probability of obtaining a pregnancy. This is useful to identify couples with a good chance of obtaining a pregnancy through an IUI procedure (2) Methods: The study was conducted at a university-level fertility clinic in Oradea, Romania. Patients eligible to participate in the study were infertile couples who underwent IUI treatment in the interval between January 2015 and October 2020. (3) Results: In our study, we found that duration of infertility, couple age, endometrium thickness, sperm concentration, and motility are important factors in determining the outcome of IUI. Several demographics were measured for each couple including maternal and paternal age, the type and duration of infertility, the number of procedures, the type of ovarian stimulation, number of follicles, endometrial thickness, the type and day of ovulation induction, associated pathology, tubal patency, and pre/post washes sperm count and progressive sperm motility. (4) Conclusions: Fertility prediction studies are necessary, and an individualized prognostic score should be applied for each couple for tailoring their expectations and better counseling.
Glioblastoma multiforme (GBM) represents one of the most critical oncological diseases in neurological practice, being considered highly aggressive with a dismal prognosis. At a worldwide level, new therapeutic methods are continuously being researched. Magnetic hyperthermia (MHT) has been investigated for more than 30 years as a solution used as a single therapy or combined with others for glioma tumor assessment in preclinical and clinical studies. It is based on magnetic nanoparticles (MNPs) that are injected into the tumor, and, under the effect of an external alternating magnetic field, they produce heat with temperatures higher than 42 °C, which determines cancer cell death. It is well known that iron oxide nanoparticles have received FDA approval for anemia treatment and to be used as contrast substances in the medical imagining domain. Today, energetic, efficient MNPs are developed that are especially dedicated to MHT treatments. In this review, the subject’s importance will be emphasized by specifying the number of patients with cancer worldwide, presenting the main features of GBM, and detailing the physical theory accompanying the MHT treatment. Then, synthesis routes for thermally efficient MNP manufacturing, strategies adopted in practice for increasing MHT heat performance, and significant in vitro and in vivo studies are presented. This review paper also includes combined cancer therapies, the main reasons for using these approaches with MHT, and important clinical studies on human subjects found in the literature. This review ends by describing the most critical challenges associated with MHT and future perspectives. It is concluded that MHT can be successfully and regularly applied as a treatment for GBM if specific improvements are made.
Fluoride conversion coatings on Mg present many advantages, among which one can find the reduction of the corrosion rate under “in vivo” or “in vitro” conditions and the promotion of the calcium phosphate deposition. Moreover, the fluoride ions released from MgF2 do not present cytotoxic effects and inhibit the biofilm formation, and thus these treated alloys are very suitable for cardiovascular stents and biodegradable orthopedic implants. In this paper, the biodegradation behavior of four new magnesium biodegradable alloys that have been developed in the laboratory conditions, before and after surface modifications by fluoride conversion (and sandblasting) coatings, are analyzed. We performed structural and surface analysis (XRD, SEM, contact angle) before and after applying different surface treatments. Furthermore, we studied the electrochemical behavior and biodegradation of all experimental samples after immersion test performed in NaCl solution. For a better evaluation, we also used LM and SEM for evaluation of the corroded samples after immersion test. The results showed an improved corrosion resistance for HF treated alloy in the NaCl solution. The chemical composition, uniformity, thickness and stability of the layers generated on the surface of the alloys significantly influence their corrosion behavior. Our study reveals that HF treatment is a beneficial way to improve the biofunctional properties required for the studied magnesium alloys to be used as biomaterials for manufacturing the orthopedic implants.