Yunhyung Hwang

Ms. Yunhyung Hwang

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Atmospheric Environment
Verified
Journal Article
Closed access
YHYunhyung Hwang
Yunhyung Hwang
KLKiyoung Lee
Kiyoung Lee

MLMiyoung Lim
Miyoung Lim
SMSainnyambuu Myagmarchuluun
Sainnyambuu Myagmarchuluun
HBHyunkyung Ban
Hyunkyung Ban
YHYunhyung Hwang
Yunhyung Hwang
COChimedsuren Ochir
Chimedsuren Ochir
Kiyoung LeeKiyoung Lee
Kiyoung Lee
Coal combustion in ger areas is the main source of ambient air pollution in Ulaanbaatar (Mongolia). This study determined the characteristics of indoor PM2.5 concentrations in gers using coal stoves during winter. The study population consisted of 60 gers in the Chingeltei district of Ulaanbaatar. The indoor particle number concentration (PNC) in each ger was measured using a Dylos DC1700 particle counter for 24 h in January and February 2016. The PNC by Dylos was converted into the mass concentration using a calibration equation developed using a collocated real-time light scattering monitor adjusted by gravimetric measurement. The average 24 h PM2.5 concentration was 203.9 ± 195.1 μg/m3 in gers with traditional stoves (n = 29) and 257.5 ± 204.4 μg/m3 in those with improved stoves (n = 31). In the daily profile, concentrations were lower at night, increased in the early morning, and peaked up to noon. The temperature in gers was slightly higher than that recommended in winter. Many development-assistance programs have supported the installation of improved energy-efficient stoves. Better control measures are needed to improve the indoor air quality of gers.

YHYunhyung Hwang
Yunhyung Hwang
JAJaehoon An
Jaehoon An
Kiyoung LeeKiyoung Lee
Kiyoung Lee
The Korea Simulation Exposure Model for fine particulate matter (PM2.5) (KoSEM-PM) was developed to estimate population PM2.5 exposure in Korea. The data were acquired based on 59,945 min of the actual microenvironmental PM2.5 measurements and on the time–activity patterns of 8072 residents of Seoul. The aims of the study were to estimate daily PM2.5 exposure of Seoul population, and to determine the characteristics of a high exposure group. KoSEM-PM estimated population exposures by applying the PM2.5 distribution to the matching time–activity patterns at 10-min intervals. The mean personal PM2.5 exposure level of the surveyed subjects in Seoul was 26.0 ± 2.7 µg/m3 (range: 21.0–40.2 µg/m3) in summer. Factors significantly associated with high exposure included day of the week, age, industry sector, job type, and working hours. Individuals surveyed on Saturdays were more likely to be in the high exposure group than those surveyed on weekdays and Sundays. Younger, non-office-working individuals with longer working hours were more likely to be in the high exposure group. KoSEM-PM could be a useful tool to estimate population exposure levels to other region in Korea; to expand its use, microenvironmental measurements are required for other region in Korea.

JKJeonghoon Kim
Jeonghoon Kim
HBHyunkyung Ban
Hyunkyung Ban
YHYunhyung Hwang
Yunhyung Hwang
KHKwonchul Ha
Kwonchul Ha
Kiyoung LeeKiyoung Lee
Kiyoung Lee
In Korea, smoke-free regulations have been gradually implemented in bars based on venue size. Smoking bans were implemented in 2013 for bars ≥150 m2, in 2014 for bars ≥100 m2, and in 2015 for bars of all sizes. The purpose of this study was to determine indoor fine particle (PM2.5) concentrations in bars before and after implementation of the smoke-free policies based on venue size. Indoor PM2.5 concentrations were measured with real-time aerosol monitors at four time points: (1) pre-regulation (n = 75); (2) after implementing the ban in bars ≥150 m2 (n = 75); (3) after implementing the ban in bars ≥100 m2 (n = 107); and (4) when all bars were smoke-free (n = 79). Our results showed that the geometric mean of the indoor PM2.5 concentrations of all bars decreased from 98.4 μg/m3 pre-regulation to 79.5, 42.9, and 26.6 μg/m3 after the ban on smoking in bars ≥150 m2, ≥100 m2, and all bars, respectively. Indoor PM2.5 concentrations in bars of each size decreased only after the corresponding regulations were implemented. Although smoking was not observed in Seoul bars after smoking was banned in all bars, smoking was observed in 4 of 21 bars in Changwon. Our study concludes that the greatest decrease in PM2.5 concentrations in bars was observed after the regulation covering all bars was implemented. However, despite the comprehensive ban, smoking was observed in bars in Changwon. Strict compliance with the regulations is needed to improve indoor air quality further.

31 October 2011 in Journal of Environmental Health Sciences
Verified
Journal Article
Closed access
PDF file
YHYunhyung Hwang
Yunhyung Hwang
Kiyoung LeeKiyoung Lee
Kiyoung Lee
SKSeo-Jin Kim
Seo-Jin Kim
YHYun-Chul Hong
Yun-Chul Hong
JJJong-Kwan Jun
Jong-Kwan Jun
SCSoo-Hun Cho
Soo-Hun Cho

28 February 2011 in Journal of Environmental Health Sciences
Verified
Journal Article
Closed access
PDF file
JYJi-Seon Yeom
Ji-Seon Yeom
YHYunhyung Hwang
Yunhyung Hwang
SSSoo-Yun Seo
Soo-Yun Seo
TKTae-Hyun Kim
Tae-Hyun Kim
KLKyung-A Lee
Kyung-A Lee
Comparison of PM2.5 Concentrations in Smoking and Non-smoking Areas by Division System in Coffee Shops secondhand smoke;indoor smoking;coffee shop;division type;$PM_{2.5}$; Under the Enforcement Rules of the National Health Promotion Act, smoking areas in coffee shops in Korea should be divided off from other areas. The effect on indoor air quality of different division types for smoking areas was evaluated. Using real-time monitors, fine particulate matter <2.5 ${\mu}m$ in diameter ($PM_{2.5}$) concentrations were measured simultaneously in the smoking and non-smoking areas of 30 coffee shops in Seoul. Average $PM_{2.5}$ concentrations in smoking and non-smoking areas were 132 ${\mu}g/m^3$ and 52 ${\mu}g/m^3$, respectively; significantly different. Average $PM_{2.5}$ concentrations in non-smoking areas were 39 ${\mu}g/m^3$ in the glass-wall type and 64 ${\mu}g/m^3$ in the separate-floor type. These $PM_{2.5}$ levels were above the US national ambient air quality standard of 35 ${\mu}g/m^3$. Although indoor $PM_{2.5}$ levels in non-smoking areas were reduced by the division, the rates of reduction were not significantly different by division type. Our results demonstrated that $PM_{2.5}$ from smoking areas can infiltrate into non-smoking areas. Therefore, a complete indoor smoking ban in coffee shops is the only way to protect customers and workers in non-smoking areas.