Ulrich Beschorner

Dr. Ulrich Beschorner

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JSJonas Salm
Jonas Salm
FIFranziska Ikker
Franziska Ikker
DNDr. Elias Noory
Dr. Elias Noory
UBUlrich Beschorner
Ulrich Beschorner
TKTobias Siegfried Kramer
Tobias Siegfried Kramer
TZThomas Zeller
Thomas Zeller
Objective: Patients with peripheral artery occlusive disease (PAD) are at risk of developing foot ulcers, which can subsequently lead to foot infections and an increased risk of amputation. In cases of severe ischemic foot infections (IFIs), the empirical use of antibiotics can be limb-saving. However, there is currently no evidence-based guidance on the choice of empirical antibiotic therapy for IFI. Methods and Design: This retrospective single-center cohort study included 216 hospitalized patients with severe IFI undergoing endovascular revascularization. Weighted-Incidence Syndromic Combination Antibiograms (WISCAs) were calculated to guide empirical antibiotic choice. Results: The two most common causative pathogens for IFI were S. aureus and P. aeruginosa, with frequencies of 19.8% and 6.1%, respectively. The calculation of WISCAs revealed a low empirical coverage of amoxicillin (AMX) or clindamycin (CLN) with 21.6% and 27.7%, respectively. The empirical coverage of amoxicillin/clavulanic-acid (AMC), trimethoprim/sulfmethoxazole (SXT), and ciprofloxacin (CIP) was 50.6%, 53.1%, and 55.4%, respectively. Piperacillin/tazobactam (PT) exhibited the highest empirical coverage, with 82.5% as calculated by WISCAs. The calculated WISCAs did not significantly alter when stratified by the clinical characteristics of the patients. Conclusions: The empirical antibiotic coverage of CLN and AMX was low. SXT represents a promising empirical alternative in the case of IFI, irrespective of comorbidities and the WIfI score. WISCAs can assist in the decision-making process regarding empirical antibiotic therapy choices in cases of IFI.

22 November 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DNDr. Elias Noory
Dr. Elias Noory
TBTanja Böhme
Tanja Böhme
JSJonas Salm
Jonas Salm
UBUlrich Beschorner
Ulrich Beschorner
LELarissa Endress
Larissa Endress
TZThomas Zeller
Thomas Zeller
Purpose: To evaluate the potential differences in characteristics of femoropopliteal in-stent restenosis (ISR) stratified by stent design with a focus on the swirling flow-inducing BioMimics 3D helical centerline stent. Methods: Patients with ISR of the superficial femoral and popliteal arteries undergoing reintervention were included in this study. The primary endpoint was the angiographic localization and extent of restenosis or reocclusion with the following five different stent systems: SMART Control stent, Supera peripheral stent, GORE® VIABAHN® endoprosthesis, BioMimics 3D stent, and Zilver® PTX® stent. Results: 414 ISR lesions were analyzed, affecting 236 Supera stents, 67 BioMimics 3D stents, 48 Zilver® PTX® stents, 38 SMART Control stents, and 25 VIABAHN® endoprostheses. The mean stent diameter and length were 5.7 ± 0.77 mm and 121.4 ± 94.8 mm, respectively. ISR included 310 (74.9%) lesions with 1 stent, 89 (21.5%) lesions with 2 stents, 14 (3.4%) lesions with 3 stents, and 1 lesion (0.2%) with 4 stents. Most lesions presented as reocclusions (67.4%) rather than focal (13.3%) or diffuse restenoses (19.3%). No significant differences in ISR lesion morphology were found. By trend, BioMimics 3D stent lesion extension was more focal (16.4% versus 12.7%, p = 0.258), with the highest proportion of lesions in which only the proximal stent third was affected (9.0% versus 5.8%, p = 0.230), as compared to the average of the other four devices. The occlusion rate was the second lowest for the BioMimics 3D stent (64.2 vs. 68.0%, p = 0.316). Risk factors for restenosis or occlusion were active smoking, pre-interventional occlusion, and popliteal intervention. Conclusion: Our results suggest that the helical centerline stent design of the BioMimics 3D stent, which results in a swirling flow with increased wall shear stress, may offer protective properties over straight stent designs, including DES and endoprosthesis, regarding localization and extension of restenosis. Prospective, randomized studies are warranted.

Verified
Journal Article
Open access
PDF file
TBTanja Böhme
Tanja Böhme
TZThomas Zeller
Thomas Zeller
MAMohamed Abboud
Mohamed Abboud
UBUlrich Beschorner
Ulrich Beschorner
DNDr. Elias Noory
Dr. Elias Noory
In many vascular segments, endovascular therapy is the treatment of choice for arteriosclerotic lesions. For the treatment of common femoral artery (CFA) lesions, surgical reconstruction is still considered the gold standard. The purpose of this study is to evaluate the safety and efficacy of stent angioplasty for the treatment of common femoral artery (CFA) lesions in a real-world population during a two-year follow up. This retrospective, single-center study includes 250 patients requiring treatment with stent angioplasty of CFA lesions. The primary end point was the target lesion revascularization (TLR) rate. Secondary end points were the overall procedural complication rate, the rate of ipsilateral CFA punctures during follow-up, changes in the Rutherford–Becker class (RBC) and ankle–brachial index (ABI), primary patency rates, amputation rate, time to and the type of TLR. A total of 236 interventions (94.4%) were successfully defined as a residual stenosis < 30%. Periinterventionally, there were 23 complications (9.1%), 3 of which had to be treated surgically. Median follow up was 21 months (average 19.2 ± 7.8). In total, 41 patients (16.4%) needed a TLR. The primary patency rate was 90.8%, 81.2% and 72% at 6, 12 and 24 months, respectively. ABI and RBC were significantly better at all time points compared to baseline. During follow up, seven amputations (three minor and four major) had to be performed. More than half of the patients (56.0%) were punctured at the stented CFA during the follow up. Multivariate logistic regression analysis showed continued nicotine use and coronary heart disease as predictors for TLR. Stent angioplasty for the treatment of CFA lesions is safe and effective. Further studies are needed to compare this endovascular option with surgical therapy.

12 August 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DNDr. Elias Noory
Dr. Elias Noory
TBTanja Böhme
Tanja Böhme
LKLeonie Krause
Leonie Krause
PRPhilipp Ruile
Philipp Ruile
JSJonas Salm
Jonas Salm
TZThomas Zeller
Thomas Zeller
Background: In addition to manual compression, various vascular closure devices (VCD) are available to seal the puncture site following arterial vascular procedures. Purpose: To evaluate the efficacy and safety of the extravascular MYNX CONTROL closure system for achieving primary hemostasis after femoral arterial access following peripheral arterial procedures, compared to the intravascular FemoSeal Aclosure system. Patients and Methods: A retrospective analysis of consecutive patients who underwent endovascular intervention between April and November 2022 was performed. The primary endpoint was the incidence of significant puncture site complication defined as a complication resulting in medical treatment. Secondary endpoints included peri-interventional incidence of hematoma, peri-interventional changes in hemoglobin, incidence of emergency diagnostics and predictors for closure system failure. Results: Five hundred and forty-eight patients were included in this analysis. False aneurysm occurred in 18/273 cases (6.6%) following the use of the MYNX closure system, compared to 6/275 cases after using the FemoSeal closure system (2.2%, p = 0.006). The incidence of post-interventional hematoma was not significantly different (28 (10.3%) in the MYNX group versus 32 (11.6%) in the FemoSeal group, p = 0.358). Peri-interventional hemoglobin drop did not differ between groups (p = 0.449). Emergency diagnostics were not significantly performed more often in the MYNX group (14 (5.1%) versus 8 (2.9%), p = 0.134). A post-interventional duplex sonography showed stenosis at the puncture site in one patient after use of the MYNX system. For the entire cohort, oral anticoagulation was the only predictor for the failure of the closure device (p = 0.036). Conclusions: Device failure was more common after using the extravascular MYNX CONTROL system than after using the intravascular FemoSeal system. However, the need for surgical or interventional therapy due to device failure was low.

26 September 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
UBUlrich Beschorner
Ulrich Beschorner
TBTanja Böhme
Tanja Böhme
DNDr. Elias Noory
Dr. Elias Noory
RBRoaa Bollenbacher
Roaa Bollenbacher
JSJonas Salm
Jonas Salm
TZThomas Zeller
Thomas Zeller
Objectives: To evaluate the safety and efficacy of catheter-directed thrombolysis (CDT) with the recombinant tissue plasminogen activator (rt-PA) in all patients with symptomatic peripheral artery disease in real world practice. Methods: Consecutive patients treated with CDT between January 2013 and December 2020 were included in this retrospective analysis. The primary endpoint was the rate of serious adverse events (SAEs) until discharge. Secondary endpoints included interventional success, predictors for SAEs, bleeding and reperfusion edema/compartment syndrome, limb salvage, and clinical outcomes including target lesion revascularization rate (TLR). Results: Overall, 1238 patients were treated with CDT. SAEs occurred in 511 (41.3%) of the patients, 314 (25.4%) being bleeding complications. There were 95 cases of reperfusion edema/compartment syndrome. Forty-two patients underwent amputation and 33 patients (2.7%) died. CDT was successful in 1177 cases (95.1%). Multivariate logistic regression analysis identified age, abciximab and alprostadil usage, and lysis duration as predictors for SAEs and the use of abciximab as a predictor of reperfusion edema/compartment syndrome. Predictors for bleeding were age, alprostadil usage, and lysis duration. At 12 and 24 months, the limb salvage rate was 91.6% and 88.8%, and TLR rate was 46% and 57.2%, respectively. Conclusions: CDT is an effective endovascular method for the treatment of thrombotic peripheral artery occlusions but is associated with a high complication rate. For SAEs in general and bleeding specifically, increasing age, alprostadil use, and lysis duration were independent risk factors.

24 August 2026 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
UTUlf Teichgräber
Ulf Teichgräber
MIMaja Ingwersen
Maja Ingwersen
TLThomas Lehmann
Thomas Lehmann
SPStephanie Platzer
Stephanie Platzer
IKIna Kunstmann
Ina Kunstmann
SISIRONA Trial Investigators
SIRONA Trial Investigators