Andreas Horbach

Mr. Andreas Horbach

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
ACAlexander Ciritsis
Alexander Ciritsis
AHAndreas Horbach
Andreas Horbach
Manfred StaatManfred Staat
Manfred Staat
CKChristiane K. Kuhl
Christiane K. Kuhl
NKNils Andreas Kraemer
Nils Andreas Kraemer

1 October 2017 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
AHAndreas Horbach
Andreas Horbach
MDMinh Tuan Duong
Minh Tuan Duong
Manfred StaatManfred Staat
Manfred Staat

1 December 2020 in Clinical Biomechanics
Verified
Journal Article
Closed access
AHAndreas Horbach
Andreas Horbach
Manfred StaatManfred Staat
Manfred Staat
DPDaniel Pérez-Viana
Daniel Pérez-Viana
HSHans-Peter Simmen
Hans-Peter Simmen
VNValentin Neuhaus
Valentin Neuhaus
BCBernhard Ciritsis
Bernhard Ciritsis

22 March 2022 in Biomechanics
Verified
Journal Article
Open access
PDF file
Aroj BhattaraiAroj Bhattarai
Aroj Bhattarai
AHAndreas Horbach
Andreas Horbach
Manfred StaatManfred Staat
Manfred Staat
WKWojciech Kowalczyk
Wojciech Kowalczyk
TTThanh Ngoc Tran
Thanh Ngoc Tran
The objective of this paper is to present our findings on the biomechanical aspects of the virgin passive anisotropic hyperelasticity of the porcine colon based on equibiaxial tensile experiments. Firstly, the characterization of the intestine tissues is discussed for a nearly incompressible hyperelastic fiber-reinforced Holzapfel–Gasser–Ogden constitutive model in virgin passive loading conditions. The stability of the evaluated material parameters is checked for the polyconvexity of the adopted strain energy function using positive eigenvalue constraints of the Hessian matrix with MATLAB. The constitutive material description of the intestine with two collagen fibers in the submucosal and muscular layer each has been implemented in the FORTRAN platform of the commercial finite element software LS-DYNA, and two equibiaxial tensile simulations are presented to validate the results with the optical strain images obtained from the experiments. Furthermore, this paper also reviews the existing models of the active smooth muscle cells, but these models have not been computationally studied here. The review part shows that the constitutive models originally developed for the active contraction of skeletal muscle based on Hill’s three-element model, Murphy’s four-state cross-bridge chemical kinetic model and Huxley’s sliding-filament hypothesis, which are mainly used for arteries, are appropriate for numerical contraction numerical analysis of the large intestine.

1 September 2018 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
AHAndreas Horbach
Andreas Horbach
Manfred StaatManfred Staat
Manfred Staat
The porosity of surgical meshes makes them flexible for large elastic deformation and establishes the healing conditions of good tissue in growth. The biomechanic modeling of orthotropic and compressible materials requires new materials models and simulstaneoaus fit of deformation in the load direction as well as trannsversely to to load. This nonlinear modeling can be achieved by an optical deformation measurement. At the same time the full field deformation measurement allows the dermination of the change of porosity with deformation. Also the socalled effective porosity, which has been defined to asses the tisssue interatcion with the mesh implants, can be determined from the global deformation of the surgical meshes.