Primary implant stability can be evaluated at the time of placement by measuring the insertion torque (IT). However, another method to monitor implant stability over time is resonance frequency analysis (RFA). Our aim was to examine the effect of bone type, implant design, and implant length on implant primary stability as measured by IT and two RFA devices (Osstell and Penguin) in an in vitro model. Ninety-six implants were inserted by a surgical motor in an artificial bone material, resembling soft and dense bone. Two different implant designs—conical connection (CC) and internal hex (IH), with lengths of 13 and 8 mm, were compared. The results indicate that the primary stability as measured by RFA and IT is significantly increased by the quality of bone (dense bone), and implant length and design, where the influence of dense bone is similar to that of CC design. Both the Osstell and Penguin devices recorded higher primary implant stability for long implants in dense bone, favoring the CC over the IH implant design. The CC implant design may compensate for the low stability expected in soft bone, and dense bone may compensate for short implant length if required by the anatomical bone conditions.

15 October 2021 in Medicina
Verified
Journal Article
Open access
PDF file
AKAdrian Kahn
Adrian Kahn
DMDaya Masri
Daya Masri
TSTamir Shalev
Tamir Shalev
HMHaya Michal Meir
Haya Michal Meir
ASAlon Sebaoun
Alon Sebaoun
LCLiat Chaushu
Liat Chaushu
Background and Objectives: The success rates of surgical dental implant insertions are high. However, knowledge of patients’ recovery is still lacking. “Health-related quality of life” (HRQOL) questionnaires are gaining popularity in all fields of medicine. The present survey assessed the perception of recovery after the surgical placement of dental implants. Materials and Methods: Forty individuals (26 women and 14 men; mean age, 55 ± 12 years) filled a questionnaire evaluating patients’ perception of recovery for 7 consecutive days post-surgery. Confounding factors included age, gender, oral habits, smoking, bruxism, bone quality (tactile evaluation) and quantity, implant location, number of implants, implant type, length and diameter, one-stage vs. two-stage, and the need for bone grafting. Results: The most serious difficulties were found in swelling, which became minimal after 5 days, followed by eating everyday food, ability to enjoy everyday food, maximal pain and average pain (3 days); analgesics consumption (2.5 days); limitations in daily routine, mouth opening, and speech (2 days); swallowing and sleep (1.5 days); and, within 1 day, all other measures attained minimal levels. Gender, and implant location (anterior vs. posterior) were significant predictor variables exerting their different characteristic delayed recoveries. Conclusions: (1) Patients should expect, in general, recovery within 4 days after dental implant placement; (2) women will experience a delayed recovery, (3) implants placed in the intercanine area will result in postoperative eating difficulties for nearly one week, and (4) the number of implants placed during the same appointment has no effect on post treatment recovery.

24 September 2021 in Materials
Verified
Journal Article
Open access
PDF file
Perry RazPerry Raz
Perry Raz
HMHaya Michal Meir
Haya Michal Meir
SLShifra Levartovsky
Shifra Levartovsky
MPMaia Peleg
Maia Peleg
ASAlon Sebaoun
Alon Sebaoun
IBIlan Beitlitum
Ilan Beitlitum
Our aim was to analyze the correlation between the IT evaluated by a surgical motor and the primary implant stability (ISQ) measured by two RFA devices, Osstell and Penguin, in an in vitro model. This study examines the effect of bone type (soft or dense), implant length (13 mm or 8 mm), and implant design (CC: conical connection; IH: internal hexagon), on this correlation. Ninety-six implants were inserted using a surgical motor (IT) into two types of synthetic foam blocks. Initial measurements for both the peak IT and ISQ were recorded at the point when implant insertion was stopped by the surgical motor, and the final measurements were recorded when the implant was completely inserted into the synthetic blocks using only the RFA devices. Our null hypothesis was that there is a good correlation between the devices, independent of the implant length, design, or bone type. We found a positive, significant correlation between the IT, and the Osstell and Penguin devices. Implant length and bone type did not affect this correlation. The correlation between the devices in the CC design was maintained; however, in the IH design it was maintained only between the RFA devices. We concluded that there is a high positive correlation between the IT and ISQ from a mechanical perspective, which was not affected by bone type or implant length but was affected by the implant design.

20 January 2026
Verified
Book Chapter
Closed access
PDF file
HMHaya Michal Meir
Haya Michal Meir
EWEvgeny Weinberg
Evgeny Weinberg
CNCarlos E. Nemcovsky
Carlos E. Nemcovsky

13 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
HMHaya Michal Meir
Haya Michal Meir
ASAlon Sebaoun
Alon Sebaoun
Perry RazPerry Raz
Perry Raz
SLShifra Levartovsky
Shifra Levartovsky
AAAdi Arieli
Adi Arieli
IBIlan Beitlitum
Ilan Beitlitum
Malpositioned and broken implants are usually fully osseointegrated; hence, their removal, especially from the lower arch, can be very challenging. Implant removal techniques include reverse torque and trephination. Trephination is an invasive technique that can jeopardize vital structures, cause mandibular fatigue fractures, or lead to osteomyelitis. In this study, we aimed to assess the relationship between trephination depth and implant stability by recording implant stability quotient (ISQ) readings at varying trephination depths in vitro. Materials and methods: Forty-eight implants were inserted into dense synthetic polyurethane foam blocks as artificial bone. Primary implant stability was measured with a Penguin resonance frequency analysis (RFA) device. Implants of two designs with a diameter of 3.75 mm and a length of 13 or 8 mm were inserted. Twenty-four internal hexagon (IH) (Seven®) and twenty-four conical connection (CC) implants (C1®; MIS® Implants, Ltd., Misgav, Israel) were used. The primary implant stability was measured with the RFA device. Trephination was performed, and implant stability was recorded at depths of 0, 3, and 6 mm for the 8 mm implants and 0, 3, 6, 8, 10, and 11.5 mm for the 13 mm implants. Results: Linear regression revealed a significant relation between the trephination depth and the ISQ (F (1, 213) = 1113.192, p < 0.001, adjusted r2 = 0.839). The trephination depth significantly predicted the ISQ (β = −5.337, p < 0.001), and the ISQ decreased by −5.33 as the trephination depth increased by 1 mm. Conclusion: Implant stability reduction as measured using an RFA device during trephination may be a valuable guide to achieving safe reverse torque for implant removal. Further studies are needed to evaluate these data in clinical settings.