Primary implant stability can be evaluated at the time of placement by measuring the insertion torque (IT). However, another method to monitor implant stability over time is resonance frequency analysis (RFA). Our aim was to examine the effect of bone type, implant design, and implant length on implant primary stability as measured by IT and two RFA devices (Osstell and Penguin) in an in vitro model. Ninety-six implants were inserted by a surgical motor in an artificial bone material, resembling soft and dense bone. Two different implant designs—conical connection (CC) and internal hex (IH), with lengths of 13 and 8 mm, were compared. The results indicate that the primary stability as measured by RFA and IT is significantly increased by the quality of bone (dense bone), and implant length and design, where the influence of dense bone is similar to that of CC design. Both the Osstell and Penguin devices recorded higher primary implant stability for long implants in dense bone, favoring the CC over the IH implant design. The CC implant design may compensate for the low stability expected in soft bone, and dense bone may compensate for short implant length if required by the anatomical bone conditions.
GBR (Guided Bone Regeneration) procedure is challenged by the risk of membrane exposure to the oral cavity and contamination. The barrier quality of these membranes serve as a mechanical block from bacterial penetration into the GBR site. The purpose of this in vitro study was to evaluate the antibacterial effect of three commercial non-resorbable polytetrafluoroethylene membranes. (Two d-PTFE membranes and one double layer e-PTFE +d-PTFE membrane). A validated in vitro model with two bacterial species (Streptococcus sanguinis and Fusobacterium nucleatum) was used. Eight samples from membrane each were placed in a 96-well microtiter plate. The experimental and positive control groups were exposed to a bacterial suspension which involved one bacterial species in each plate. Bacterial growth was monitored spectrophotometrically at 650 nm for 24 h in temperature controlled microplate spectrophotometer under anaerobic conditions. One- Sample Kolmogorov–Smirnov Normal test and the Kruskal–Wallis test was used for the statistical analysis. As shown by the bacterial growth curves obtained from the spectrophotometer readings, all three membranes resulted in bacterial growth. We have not found a statistical difference in F. nucleatum growth between different membrane samples and the positive control group. However, S. sanguinis growth was reduced significantly in the presence of two membranes (CYTOPLAST TXT-200 and NeoGenTM) when compared to the control (p < 0.01). The presence of Permamem® had no significant influence on S. sanguinis growth. Some types of commercial non-resorbable PTFE membranes may have an impact on the growth dynamics of specific bacterial species.
The aim of this study was to assess retrospectively the survival and success rates of monolithic zirconia restorations supported by teeth and implants in bruxer versus non-bruxer patients. Methods: A total of 15 bruxer and 25 non-bruxer patients attended the recall appointment. The bruxer group (mean age of 61.2 ± 13.3 years and follow-up of 58.7 ± 16.8 months) were treated with 331 monolithic zirconia restorations, while the non-bruxer group, with a comparable mean age and follow-up time, were treated with 306 monolithic zirconia restorations. Clinical data were retrieved from the patients’ files. At the recall appointment, all supporting teeth and implants were examined for biological and technical complications, and the restorations were evaluated using modified California Dental Association (CDA) criteria. Data were statistically analyzed using survival analysis methods. A significance level of p < 0.05 was used. A total of 31 versus 27 biologic and technical complications were recorded in the bruxer and non-bruxer groups, respectively. No significant differences were found between the two groups regarding overall complications and survival rate. Regarding the type of complication, a significantly higher rate of veneered porcelain chipping (p = 0.045) was observed in the bruxer group. With regard to biological complications, the only complications that exhibited a borderline, although not significant, difference were three fractured teeth exclusively in the bruxer group (p = 0.051), which were replaced with implant-supported restorations. Within the limitations of this study, we conclude that there were no significant differences in the overall survival and success rates of the monolithic zirconia restorations in bruxer versus non-bruxer patients, although veneered zirconia restorations and single tooth abutments exhibited a higher rate of complications in the bruxer group.
To compare the three-dimensional accuracy of an open-tray and two snap on impression techniques (with and without connecting the plastic caps of the snap on impression transfers) in a full arch 6-implant model, a reference acrylic resin model of the maxilla with six implants was fabricated. Prominent geometrical triangles, in the palate area, served as reference points for a digital overlap between scans. Three impression transfer techniques were evaluated and compared: open-tray direct impression (DI), snap on impression (SpO), and connected snap on impression (SpOC). Polyether impression material was used to make 30 impressions (n = 10), and the master model and all casts were digitally scanned with a laboratory optical scanner. The obtained 3D data were converted and recorded as STL files, which were imported to a 3D inspection software program. Angular deviations (buccal, occlusal and interproximal planes) between the study casts and the reference model were measured. Data were analyzed using one-way analysis of variance (ANOVA) and Tukey post hoc test, with 0.05 used as the level of significance. The 3D angular deviations from the master model revealed no significant differences between the DI and SpO impression groups, but there were significant differences in the SpOC impression group, particularly in the buccal and occlusal planes. In all groups, the 3D angular deviation between the most distal scan abutments on each side of the model was significantly different from all other areas when compared to the master model. Within the limits of this study, it is possible to conclude that the indirect closed tray snap on impression technique with unconnected plastic caps exhibited the same three-dimensional accuracies as the direct open tray technique. The indirect closed tray snap on impression technique with connected plastic caps was less accurate than either the indirect closed tray snap on impression technique with unconnected plastic caps or the direct open tray technique. In the case of full arch implant supported prostheses, inaccuracies may be expected in the most distal implants for all the three impression techniques evaluated in this study. Further in vitro and in vivo research is required.
Background: All-on-four protocols with tilted implants in the maxilla are used to rehabilitate the terminal dentition of the severe generalized periodontitis patients. Data on long-term biological complications are scarce. Methods: Eighty-four axial and forty-six tilted immediate implants have been placed in the extraction sockets of 23 patients according to a four–six implants protocol combined with ridge augmentation. Within 72 h, a provisional prosthesis was cemented to the implants; after 6 months, a cemented ceramic–metallic prosthesis was delivered. The patients were followed for up to 5 years. Results: The 5-year survival rate of the straight and tilted implants was 100% and 97.8, and the prosthetic one was 100%. Marginal bone loss (MBL) of the straight implants was 0.42 ± 0.67 and 0.59 ±1.01 mm on the mesial and distal sides; for the tilted, it was 0.37 ± 0.68 and 0.34 ±0.62 mm, and the differences were not statistically significant. Implant position, smoking, keratinized mucosal width, and cantilever did not affect MBL. Peri-implant mucositis involved 29.4% and 22.2% of the straight and tilted implants, respectively; peri-implantitis involved 5.8% and 4.4% of the straight and tilted implants, respectively, without statistical significance. Conclusions: This immediate loading protocol’s 5-year survival and success rates were high. No difference between the straight and tilted implants was found regarding survival, success rates, and MBL.
Our aim was to analyze the correlation between the IT evaluated by a surgical motor and the primary implant stability (ISQ) measured by two RFA devices, Osstell and Penguin, in an in vitro model. This study examines the effect of bone type (soft or dense), implant length (13 mm or 8 mm), and implant design (CC: conical connection; IH: internal hexagon), on this correlation. Ninety-six implants were inserted using a surgical motor (IT) into two types of synthetic foam blocks. Initial measurements for both the peak IT and ISQ were recorded at the point when implant insertion was stopped by the surgical motor, and the final measurements were recorded when the implant was completely inserted into the synthetic blocks using only the RFA devices. Our null hypothesis was that there is a good correlation between the devices, independent of the implant length, design, or bone type. We found a positive, significant correlation between the IT, and the Osstell and Penguin devices. Implant length and bone type did not affect this correlation. The correlation between the devices in the CC design was maintained; however, in the IH design it was maintained only between the RFA devices. We concluded that there is a high positive correlation between the IT and ISQ from a mechanical perspective, which was not affected by bone type or implant length but was affected by the implant design.