Shifra Levartovsky

Dr. Shifra Levartovsky

Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SLShifra Levartovsky
Shifra Levartovsky
SMSoad Msarwa
Soad Msarwa
SRShoshana Reiter
Shoshana Reiter
IEIlana Eli
Ilana Eli
EWEfraim Winocur
Efraim Winocur
RSRachel Sarig
Rachel Sarig
Psychosocial factors may play an important role in the etiology of sleep and awake bruxism. The purpose of this study was to assess the relationship between emotional stress and bruxism in male and female dental students at various stages of their education. Dental education in Israel is based on a six-year curriculum, divided into three stages: pre-medical studies (yr. 1–2), manual skills (yr. 3–4), and clinical experience (yr. 5–6). Each stage requires different capabilities and skills. Questionnaires regarding psychological state (SCL-90) measuring depression, anxiety, and somatization as well as stress evaluation questioners (Perceived Stress Scale questionnaire 14) were completed by 387 dental students in the 1st to 6th years. Sleep and awake bruxism were evaluated based on the respondent’s awareness. During the manual stage of studies, a significant increase was identified, albeit with weak correlations, between stress scales, depression, anxiety, somatization, and the prevalence of awake bruxism, particularly among males. Only in females was sleep bruxism correlated with emotional parameters, whereas no significant difference in sleep bruxism was observed in males throughout the stages of the study. The manual years of dental education were found to be linked to higher levels of emotional distress and awake bruxism, particularly in men. Sleep bruxism, on the other hand, was not directly linked to emotional factors, implying a distinct etiology.

25 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
OAorit winocur arias
orit winocur arias
EWEfraim Winocur
Efraim Winocur
TSTamar Shalev-Antsel
Tamar Shalev-Antsel
SRShoshana Reiter
Shoshana Reiter
SLShifra Levartovsky
Shifra Levartovsky
PRPessia Friedman Rubin
Pessia Friedman Rubin
Aim: To evaluate the effect of the current coronavirus pandemic on the prevalence of bruxism, oral parafunctions and painful Temporo-Mandibular Disorders (TMDs) and to evaluate the influence of the pandemic on both sexes. Methods: This retrospective study included 288 dental patients who underwent complete anamnesis and examination according to the Diagnostic Criteria for TMD. The study evaluated two patient populations according to the date of examination: (a) pre-COVID-19 pandemic era (108 patients); (b) COVID 19 pandemic era, where 180 patients were examined during the pandemic. Results: A significant increase in parafunction activity was found in both men and women (p < 0.001) during the COVID-19 pandemic. Awake bruxism (AB) and sleep bruxism (SB) was more prevalent during the COVID-19 pandemic solely in women (AB-p < 0.001; SB-p = 0.014). Conclusions: Men and women were affected by the ongoing stress due to the COVID-19 pandemic, yet women showed a higher influence as compared to men. The long-term exposure to elevated levels of anxiety and stress may aggravate or trigger stomatognathic detrimental conditions. Dentists should be aware and regularly monitor their patients regarding the possible existence and consequences of bruxism and TMD.

1 October 2019 in Journal of Prosthodontic Research
Verified
Journal Article
Closed access
SLShifra Levartovsky
Shifra Levartovsky
RPR. Pilo
R. Pilo
ASA. Shadur
A. Shadur
SMS. Matalon
S. Matalon
EWE. Winocur
E. Winocur
To assess the clinical performance of the complete rehabilitation of a series of patients with bruxism treated by teeth- and implant-supported veneered and non-veneered zirconia restorations with an increased vertical dimension of occlusion (VDO). Ten patients with bruxism, aged 62-70 years, were treated with 108 veneered and 142 non-veneered zirconia restorations and attended the recall appointment. The mean observation period was 28.2 (±16.8) months. The patients were identified from records, and clinical details were retrieved from their files. In the recall appointment, the restorations were evaluated using modified California Dental Association (CDA) criteria. The periodontal probing depth, bleeding index, presence of caries and implant survival and success rate were recorded. No biological complications were recorded for any restorations. The success and survival rate of all implants was 100%. The overall mean survival and success rate of all restorations was 99.6%. In the veneered group, the predominant complication was minor veneer chipping (13.9%) on the incisal edge, which required only polishing (grade 1); in the non-veneered group, the predominant failure was open proximal contacts between the implant restoration and adjacent teeth (9%); only one implant restoration needed repair. One restoration was replaced due to a horizontal tooth fracture. Within the limitations of this study, we conclude that the survival and success rate of monolithic zirconia restorations installed in patients with bruxism was excellent, although the veneered zirconia restorations showed a high rate of minor veneer chipping, which required only polishing.

31 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SLShifra Levartovsky
Shifra Levartovsky
GPGitit Peleg
Gitit Peleg
Shlomo MatalonShlomo Matalon
Shlomo Matalon
ITIgor Tsesis
Igor Tsesis
EREyal Rosen
Eyal Rosen
The aims of the current study were as following: (1) to evaluate the maximal bite forces in patients with dental implants versus patients without dental implants, as measured by a digital bite force transducer (GM10); (2) to evaluate the influences of sex, age, and sleep/awake bruxism on the maximal bite forces of the two groups. Forty patients recruited to the study were divided into two groups: test group (“implant”) if they had one or more posterior restored implants and control group (“no-implant”) without the presence of posterior dental implants. A digital bite fork (GM10) was used to measure the bite forces from three posterior occluding pairs in all participants. Differences in the mean values between the test and control groups and between different sexes were evaluated using one-way and two-way ANOVA tests. A cross-tabulation analysis was conducted to identify a trend line between the groups. There was no significant difference in the maximal bite force between the test and control groups (p = 0.422), but the cross-tabulation analysis revealed a clear trend of a stronger representation of the “no-implant” group at higher occlusal forces. A significant difference was detected between the maximal biting forces of male and female subjects (p = 0.030 in the implant group, p = 0.010 in the no-implant group), regardless of the experimental group. The presence of bruxism and clenching did not influence the bite force values (p = 0.953), and a significant difference was not found between the age groups (p = 0.393). Within the limitations of this study, it may be assumed that there was no significant difference between the maximal bite forces between patients with and without dental implants but that there was a trend line implicating a stronger representation of the “no-implant” group at higher forces. In addition, the results revealed a significant sex-related difference in the maximal occlusal force. Further studies with larger sample sizes are warranted.

15 June 2021 in Materials
Verified
Journal Article
Open access
PDF file
SLShifra Levartovsky
Shifra Levartovsky
HBHilla Bohbot
Hilla Bohbot
KSKeren Shem-Tov
Keren Shem-Tov
TBTamar Brosh
Tamar Brosh
Raphael PiloRaphael Pilo
Raphael Pilo
The aim of the current study was to evaluate the influence of hydrofluoric (HF) acid concentration and conditioning time on the shear bond strength (SBS) of dual cure resin cement to pressed lithium disilicate ceramic compared to treatment with an Etch and Prime self-etching glass-ceramic primer (EP). A total of 100 samples of pressed lithium disilicate (IPS e.max Press, Ivoclar Vivadent) were randomly divided into five groups (n = 20) according to surface treatment: two different concentrations of HF (5% or 9%), for different durations (20 or 90 s), or treatment with EP. Adhesion of light-cured resin cement to the treated surface was tested by the SBS test. The substrate surfaces of the specimen after failures were examined by SEM. Data were analyzed using Weibull distribution. The highest cumulative failure probability of 63.2% of the shear bond strength (η parameter) values was in the 9% HF −90 s group (17.71 MPa), while the lowest values were observed in the 5% HF −20 s group (7.94 MPa). SBS values were not affected significantly by the conditioning time (20 s or 90 s). However, compared to treatment with 5% HF, surface treatment with 9% HF showed a significantly higher η (MPa) as well as β (reliability parameter). Moreover, while compared to 9% HF for 20 s, EP treatment did not differ significantly in SBS values. Examination of the failure mode revealed a mixed mode of failure in all the groups. Within the limits of this study, it is possible to assume that IPS e.max Press surface treatment with 9% HF acid for only 20 s will provide a better bonding strength with resin cement than using 5% HF acid.

23 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
Perry RazPerry Raz
Perry Raz
HMHaya Michal Meir
Haya Michal Meir
SLShifra Levartovsky
Shifra Levartovsky
ASAlon Sebaoun
Alon Sebaoun
IBIlan Beitlitum
Ilan Beitlitum
Primary implant stability can be evaluated at the time of placement by measuring the insertion torque (IT). However, another method to monitor implant stability over time is resonance frequency analysis (RFA). Our aim was to examine the effect of bone type, implant design, and implant length on implant primary stability as measured by IT and two RFA devices (Osstell and Penguin) in an in vitro model. Ninety-six implants were inserted by a surgical motor in an artificial bone material, resembling soft and dense bone. Two different implant designs—conical connection (CC) and internal hex (IH), with lengths of 13 and 8 mm, were compared. The results indicate that the primary stability as measured by RFA and IT is significantly increased by the quality of bone (dense bone), and implant length and design, where the influence of dense bone is similar to that of CC design. Both the Osstell and Penguin devices recorded higher primary implant stability for long implants in dense bone, favoring the CC over the IH implant design. The CC implant design may compensate for the low stability expected in soft bone, and dense bone may compensate for short implant length if required by the anatomical bone conditions.