The Shunbei crude oil pipeline is prepared to use the unheated transportation process to transport waxy crudes. However, the wax formation in the pipeline is unknown. In order to predict the wax deposition of the pipeline, the physical property experiment of Shunbei crude oil was carried out through field sampling. The density, freezing point, hydrocarbon composition, and viscosity–temperature characteristics of crude oil are obtained. The cloud point and wax precipitation characteristics of the crude oil were obtained using the differential scanning calorimetry (DSC) thermal analysis method. Then, the wax deposition rate of the pipeline was predicted by two methods: OLGA software and wax deposition kinetic model. Finally, the optimal pigging cycle of the pipeline was calculated on this basis. The results show that: Shunbei crude oil is a light crude oil with low wax content, a low freezing point, and a high cloud point. Comparing the OLGA simulation results with the calculation results of the Huang Qiyu model, the development trend of wax deposition along the pipeline was the same under different working conditions. The relative error of the maximum wax layer thickness was 6%, proving that it is feasible for OLGA to simulate wax deposition in long-distance crude oil pipelines. Affected by the wax precipitation characteristics of Shunbei crude oil, there was a peak of wax precipitation between the pipeline section where crude oil temperature was 9.31–13.31 °C and the recommended pigging cycle at the lowest throughput was 34 days in winter and 51 days in spring and autumn.
The three-phase separator is one of the most important pieces of equipment in the combined station of the oilfield. The control level of the oil–water interface directly affects the energy consumption of the subsequent production of the combined station and the effect of oil, gas and water separation. In order to avoid these situations, the Siemens PLC control system, configuration software WinCC and MATLAB were used. The OPC technology is used to connect communication between WinCC and MATLAB, and the genetic algorithm in MATLAB is used to obtain the optimal separation height of the oil–water interface under the produced liquid in different periods. Subsequently, through the Siemens PLC system and WinCC configuration software, the automatic control of the three-phase separator is achieved, and finally the water content of crude oil is significantly reduced. The system provides a visual interface function. In the future, it will also provide an effective simulation platform for the theoretical research and design of an automatic control system of an oilfield combined station.
An intermediate fluid vaporizer (IFV) is a typical vaporizer of liquefied natural gas (LNG), which is used in a large number of LNG terminals. Since it requires a large supply of seawater during its operation, it generates a lot of energy consumption. In this study, to reduce the seawater consumption in the regasification system, the heat transfer process was first numerically calculated, and the heat transfer coefficient of the IFV was determined for different seawater inlet temperatures, seawater flow rates, and LNG flow rates. The calculation results of the heat transfer coefficient were integrated into the numerical model in HYSYS, and the minimum seawater flow of the IFV under different working conditions was obtained. For receiving terminals using multiple IFVs, this study programmed calculations based on optimization software. The operating configuration of the IFVs under different operating conditions was optimized to reduce the consumption of seawater in the regasification system of the LNG terminals.
Photoelectrochemical (PEC) urea splitting is of great significance for urea wastewater remediation and hydrogen production with low energy consumption simultaneously. Nickel hydroxides as electrocatalysts have been widely investigated for urea electrolysis. However, it is an open question how to synthesize highly catalytic Ni(OH)2 for the PEC urea splitting. Herein, we take advantage of the instability of metal–organic frameworks (MOFs) to perform an in situ synthesis of Ni(OH)2 catalysts on the surface of TiO2 nanorod arrays. This transformed Ni(OH)2 (T-Ni(OH)2) possesses a superior PEC catalytic activity for water/urea splitting in comparison to the Ni(OH)2 prepared by the impregnation method. The in situ transition of a Ni-MOF is accomplished through an electrochemical treatment under AM1.5G illumination in a KOH-and-urea mixed electrolyte. The specific transition mechanism of Ni-MOFs is the substitution of ligands with OH− in a 1 M KOH electrolyte and the successive phase transition. The T-Ni(OH)2@TiO2 photoanode delivers a high photocurrent density of 1.22 mA cm−2 at 1.23 VRHE, which is 4.7 times that of Ni(OH)2@TiO2 prepared with the impregnation method. The onset potential of T-Ni(OH)2@TiO2 is negatively shifted by 118 mV in comparison to TiO2. Moreover, the decline of photocurrent during the continuous test can be recovered after the electrochemical and light treatments.
Under the guidance of China’s goal of achieving carbon neutrality by 2060, the petrochemical industry is increasingly adopting energy-saving and emission-reduction technologies. To realize the low carbon operation of the LNG (liquefied natural gas) receiving terminal, an innovative SCV (submerged combustion vaporizer) flue gas carbon capture system using LNG cold energy was established, and the system also combined with an ORC (organic Rankine cycle). HYSYS software was used to simulate the process of the SCV flue gas carbon capture system and the LNG regasification system. The simulation results showed that the proposed system has low carbon emission and low energy consumption performance. Moreover, the sensitivity analysis of the evaporation pressure of working fluids, CO2 capture pressure, and CO2 capture temperature was carried out. The key parameters were optimized by HYSYS software to achieve the optimal operation cost of the system. When the evaporation pressure of working fluids, CO2 capture pressure, and CO2 capture temperature were set as 1300 kPa, 750 kPa, and 143.15 K, respectively, the optimized system resulted in an exergy efficiency of 13.63%, an LNG cold exergy utilization rate of 77.49%, a CO2 capture rate of 94.9%, and a CO2 capture capacity of 6620.4 kg/h.
This paper focuses on improving the operating efficiency of the Liquified Natural Gas (LNG) submerged pump system in the LNG receiving terminals and achieve energy saving. The minimum input energy consumption of the LNG submerged pump system is taken as the objective function, and an optimization model for the operation of the LNG submerged pump system with variable frequency speed is established. LINGO18.0 optimization software is used to solve the model to get the optimal LNG submerged pump operation plan that satisfies the constraints. Taking a certain LNG receiving terminal as an example, the operation optimization of its LNG submerged pump system is carried out, and the input energy consumption of the system before and after optimization is compared. The results show that the use of variable frequency pumps can reduce the energy consumption of the LNG submerged pump system of LNG receiving terminals, and the optimization model can reduce the input power consumption of the system by about 10% under different transportation conditions. After applying the optimization model to actual production, it is found that the model has certain practicability for guiding the production of LNG receiving terminal.