An intermediate fluid vaporizer (IFV) is a typical vaporizer of liquefied natural gas (LNG), which is used in a large number of LNG terminals. Since it requires a large supply of seawater during its operation, it generates a lot of energy consumption. In this study, to reduce the seawater consumption in the regasification system, the heat transfer process was first numerically calculated, and the heat transfer coefficient of the IFV was determined for different seawater inlet temperatures, seawater flow rates, and LNG flow rates. The calculation results of the heat transfer coefficient were integrated into the numerical model in HYSYS, and the minimum seawater flow of the IFV under different working conditions was obtained. For receiving terminals using multiple IFVs, this study programmed calculations based on optimization software. The operating configuration of the IFVs under different operating conditions was optimized to reduce the consumption of seawater in the regasification system of the LNG terminals.
The thermal insulation performance of liquid hydrogen (LH2) storage tanks is critical for long-distance transportation. The active cooled shield (ACS) technologies, such as the liquid nitrogen cooled shield (LNCS) and the vapor hydrogen cooled shield (VHVCS) are important thermal insulation methods. Many researchers installed the VHVCS inside the multilayer insulation (MLI) and obtained the optimal position. However, the MLI layer is often thinner than the vacuum interlayer between the inner and outer tanks, and there is a large vacuum interlayer between the outermost side of MLI and the inner wall of the outer tank. It is unknown whether the insulation performance can be improved if we install ACS in the mentioned vacuum interlayer and separate a portion of the MLI to be installed on the outer surface of ACS. In this configuration, the number of inner MLI (IMLI) layers and the ACS position are interdependent, a coupling that has not been thoroughly investigated. Therefore, thermodynamic models for MLI, MLI-LNCS, and MLI-VHVCS schemes were developed based on the Layer-by-Layer method. By applying Robin boundary conditions, the temperature distribution and heat leakage of the MLI scheme were predicted. Considering the coupled effects of IMLI layer count and ACS position, a co-optimization strategy was adopted, based on an alternating iterative search algorithm. The results indicate that for the MLI-LNCS scheme, the optimal number of IMLI layers and LNCS position are 36 layers and 49%, respectively. For the MLI-VHVCS scheme, the optimal values are 21 layers and 39%, respectively. Compared to conventional MLI, the MLI-LNCS scheme achieves an 88.09% reduction in heat leakage. However, this improvement involves increased system complexity and higher operational costs from LN2 circulation. In contrast, the MLI-VHVCS scheme achieves a 62.74% reduction in heat leakage, demonstrating that using sensible heat from cryogenic vapor can significantly improve the thermal insulation performance of LH2 storage tanks. The work of this paper provides a reference for the design and optimization of the insulation scheme of LH2 storage tanks.
Long-distance natural gas pipelines with internal corrosion defects are susceptible to fatigue failure under operational pressure fluctuations, posing significant risks to infrastructure integrity and safety. To address this, the present study employs a finite element methodology, utilizing Ansys Workbench to model pipelines of various specifications with parametrically defined corrosion defects, and nCode DesignLife to predict fatigue life based on Miner’s linear cumulative damage theory. The S-N curve for X70 steel was directly adopted, while a power-function model was fitted for X80 steel based on standards. A cleaned real-world pressure-time history was used as the load spectrum. Parametric analysis reveals that defect depth is the most influential factor, with a depth coefficient increase from 0.05 to 0.25, reducing fatigue life by up to 67.5%, while the influence of defect width is minimal. An empirical formula for fatigue life prediction was subsequently developed via multiple linear regression, demonstrating good agreement with simulation results and providing a practical tool for the residual life assessment and maintenance planning of in-service pipelines.