The use of Ground Source Heat Pumps (GSHPs) has grown exponentially around the world over recent decades. The GSHP represents an alternative device to electric heating systems and oil boilers. Additionally, it requires a lower power consumption and less maintenance than combustion-based heating systems. Moreover, the CO emissions produced by a GSHP are lower than other systems based on burning oil, gas, or biomass. However, the main obstacle for the widespread use of GSHPs is the high cost of Ground Heat Exchanger (GHE) installation, a technology that exhibits low thermodynamic efficiencies. Over the past decade, some studies have been conducted to improve heat transfer in GHE pipes using traditional working fluids, creating new pipe materials or designing new heat exchanger configurations. The main contribution of this paper is a summarization of the outcomes of theoretical, numerical and experimental studies to improve heat transfer in GHEs using nanotechnology. Additionally, the development of new fluids (nanofluids) and new materials (nanoparticles and nanocomposites) applied to heat exchanger pipes and the designs and configurations of GHEs are highlighted. As a result, the present review provides a perspective for future research regarding the use of nanotechnology to reduce the costs involved in GHE for GSHP improvement.
16 December 2022 in Tendencias en energías renovables y sustentabilidad
En este artículo se presenta un extenso trabajo de investigación sobre los sistemas de bombas de calor que funcionan con energía geotérmica y aerotérmica desarrollados en México. Se da una descripción de siete sistemas principales: (a) una bomba de calor agua-aire para un kínder y una bomba de calor tipo combo agua-aire y agua-agua para una clínica del IMSS, ambos sistemas diseñados para calefacción ubicados en Los Humeros, Puebla; (b) tres bombas de calor agua-aire para refrigerar/calentar dos laboratorios en Mexicali, BC; (c) una bomba de calor agua-aire para refrigerar una sala de juntas en Cuernavaca, Morelos; (d) un sistema de bomba de calor agua-agua para un club campestre y cuatro bombas de calor aire-aire para un Hotel, ambos sistemas fueron diseñados para refrigerar/calentar los edificios y se localizan en Aguascalientes, Aguascalientes; y (e) un sistema híbrido con una bomba de calor aire-aire que incluye el uso de energía solar fotovoltaica localizado en León, Guanajuato.
From a literature review, various concepts and methodologies useful for the development of the preliminary stages of planning and design of a ground source heat pump were documented. A prototype of a cooling system for a room in the Universidad EIA was proposed. The heat pump selected to supply the demand has a power of 1-9 kW, and the proposed heat exchanger system corresponds to a closed-loop horizontal slinky-type with an approximate pipe length of 1,301 m, which was calculated through Excel spreadsheets and configured in three or six trenches with a total area required for the installation of 911 and 952 m2, respectively. These results provide the initial conditions for the implementation of an air conditioning project at the site, using shallow geothermal energy. Other alternatives for the heat exchanger systems and considerations for future projects are also presented.