Branka Trifkovic

Branka Trifkovic

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2022 in Journal of Oral Implantology
Verified
Journal Article
Closed access
PDF file
AMAleksa Marković
Aleksa Marković
TMTijana Mišić
Tijana Mišić
BJBojan Janjić
Bojan Janjić
MŠMiodrag Šćepanović
Miodrag Šćepanović
BTBranka Trifkovic
Branka Trifkovic
MDMichel M. Dard
Michel M. Dard
The aim was to: (1) compare changes among primary and secondary implant stability between immediate and early loaded implants in edentulous maxilla, (2) evaluate oral health-related quality of life (OHRQoL), and (3) determine patient satisfaction with 6 implant supported fixed full-arch dentures. A prospective, randomized controlled clinical trial was conducted on 24 edentulous maxilla patients. The BLT SLActive implants in 12 patients were immediately loaded with temporary restorations while 12 patients did not receive temporary restorations. Definitive (final) dentures were delivered to all patients after 6 weeks. Stability of the implants were assessed by insertion torque (IT) and resonance frequency analysis (RFA). Oral Health Impact Profile-19 (OHIP-19) questionnaire was used to evaluate OHRQoL and a visual analogue scale (VAS) was used for patient satisfaction. The IT value of implants assigned for immediate and early loading group was 27.17 ± 9.55 Ncm and 25.01 ± 11.06 Ncm, respectively. Changes in implant stability from baseline to week 6 were similar in both groups when measured by Penguin (P = .881) and Ostell (P = .828). Patients in the immediate loading group reported significantly lower OHIP physical pain scores (P = .016) and OHIP psychological disability score (P = .046), and the patients reported significantly higher VAS function score (P = .009) and VAS esthetics score (P = .009). Implant loading protocols do not have a significant effect on the change in implant stability 6 weeks after implantation; however, immediate loading significantly improves OHRQoL as well as satisfaction of patients with maxillary edentulism treated by fixed full-arch dentures. Future trials will determine the role of immediate loading protocol in clinical scenarios with various amounts of available jaw bone using different numbers of implants to retain a fixed prosthetic restoration in the edentulous maxilla.

26 July 2022 in Clinical Oral Investigations
Verified
Journal Article
Open access
PDF file
Vesna MileticVesna Miletic
Vesna Miletic
BTBranka Trifkovic
Branka Trifkovic
DSDejan Stamenkovic
Dejan Stamenkovic
RTRubens Nisie Tango
Rubens Nisie Tango
RPRade Dušan Paravina
Rade Dušan Paravina
Objectives: To evaluate CIEDE2000/CIELAB differences in color (ΔE00/ΔEab), and translucency parameter (ΔTP00/ΔTPab), and gloss of gingiva-colored resin-based restorative materials upon staining/aging. Materials and methods: Disc-shaped, 10 mm in diameter, and 2-mm-thick samples (n = 5/group) were made from giomer (Beautifil II gingiva), oligomer-based (crea.lign GUM gel), CAD/CAM polymethyl-methacrylate-based (IvoBase CAD), PMMA-based (ProBase Hot), and dimethacrylate-based (SR Nexco Paste Gingiva). Color and gloss were recording using a benchtop spectrophotometer and gloss meter, respectively, at baseline (T0), and upon staining in coffee or red wine for 60 (T1) and 120 h (T2), or artificial aging of 150 kJ/m2 (T1) and 300 kJ/m2 (T2). Three-way analysis of variance (materials x staining conditions x time intervals), Tukey’s test (α = 0.05), and Pearson’s correlation test were used in analytical statistics. Results: CIEDE2000 color differences ranged from 1.0 to 4.4 (coffee), 1.5 to 5.3 (wine), and 0.9 to 2.0 after artificial aging, with ΔE00 values being significantly higher for Beautifil than other materials (p < 0.05). ΔTP00 values ranged from 0.2 to 0.7 and were statistically higher upon staining in wine compared to artificial aging (p < 0.05). Gloss values at T0 were 76.7–87.0. Beautifil exhibited the lowest gloss retention (50.8–60.2%) after staining, compared to > 90% of other materials (p < 0.05). ΔE00/ΔEab and ΔTP00/ΔTPab were positively correlated (p < 0.0001). Conclusions: Color, translucency, and gloss changes of gingiva-colored restorative materials were material- and staining/aging-dependent. Generally, wine caused greatest changes in color (with IvoBase CAD being the most color stable) and translucency parameter. All materials except Beautifil gingiva II exhibited staining- and aging-dependent gloss retention greater than 90% for all compared time intervals. Clinical relevance: Optical properties of resin-based gingiva-colored restorative materials depend on material, staining/aging conditions, and exposure time. Certain materials should be avoided in individuals with high consumption of red wine and coffee.

7 May 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Daniela StoevaDaniela Stoeva
Daniela Stoeva
GMGalena Mateeva
Galena Mateeva
DJDanimir Jevremovic
Danimir Jevremovic
AJAna Radojica Jevremović
Ana Radojica Jevremović
BTBranka Trifkovic
Branka Trifkovic
DFDimitar Filtchev
Dimitar Filtchev
Background: Modern dentistry demands accurate finish line designs for abutments. CAD/CAM systems enable the fabrication of thin prosthetic structures to fulfill this requirement. The aim of this study is to research the mechanical resistance of customized implant abutments with different types of marginal design in laboratory environment. The null hypothesis is there is no difference in fatigue loading and compression strength in custom implant abutments with chamfer or vertical marginal design. Methods: The study model includes 60 specimens of implant suprastructures, organized into four test groups, by the margin design and used material: Group A—suprastructures, made of monolithic zirconia implant crown and titanium custom abutment with vertical marginal design; Group B—suprastructures, monolithic lithium disilicate implant crown and titanium custom abutment with vertical marginal design; Group C—suprastructures, made of monolithic zirconia implant crown and titanium custom abutment with chamfer marginal design; and Group D—suprastructures, made of monolithic lithium disilicate implant crown and titanium custom abutment with chamfer marginal design. All samples were subjected to fatigue loading test in chewing Simulator CS-4 (SD-Mechatronik, Westerham, Germany) for 1250,000 cycles, at a frequency of 2 Hz. The specimens, which survived, was conducted to compressive strength test in universal testing machine Instron M 1185 (Instron, Norwood, MA, USA). Results: The results analysis highlighted Group A as the most resistant to compressive forces (4411 MPa). Group D was with lowest values (1864 MPa)—twice than Group A. Group B (3314 MPa) had lower results than Group A, but higher than Groups C (3130 MPa) and D. Conclusion: Compression strength significantly depends on the choice of marginal design of implant abutments. Vertical margin design has better performance, that chamfer one.

16 May 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GIGeorgi Iliev
Georgi Iliev
DFDimitar Filtchev
Dimitar Filtchev
BTBranka Trifkovic
Branka Trifkovic
DJDanimir Jevremović
Danimir Jevremović
ZPZhanina Pavlova
Zhanina Pavlova
Daniela StoevaDaniela Stoeva
Daniela Stoeva
Background: Appropriate abutment selection according to the individual specificities of each patient is a leading factor in achieving high aesthetic results. Standardized titanium abutments are the most widely used due to their easy use and low cost. It is considered that customized abutments can eliminate many of the complications seen with factory abutments in prosthetic treatment. The purpose of this study is to evaluate whether customized abutments have better mechanical behavior in laboratory settings than standard ones. The null hypothesis is that customized abutments have better resistance to cyclic load and compression than factory abutments. Methods: The study model includes thirty implant suprastructure samples, fabricated digitally, divided into three groups according to the type of implant abutment and the used material: Group A (control group) comprised monolithic implant crowns made of zirconium dioxide and a titanium base; Group B (test group) comprised monolithic implant crowns made of zirconia implant crowns and a customized titanium alloy abutment; and Group C (test group) comprised monolithic implant crowns made of lithium disilicate and a customized titanium alloy abutment. The samples were subjected to dynamic load in a computer-controlled 2-axis machine that simulated masticatory movements, Chewing Simulator CS-4 (SD-Mechatronik, Westerham, Germany), for 250,000 cycles at a frequency of 2 Hz. The samples were then subjected to compressive strength testing in an Instron M 1185 universal testing machine. A metal steel disc was used as an antagonist, exerting pressure at a rate of 2 mm/min at room temperature on each sample. After conducting the laboratory tests, the samples were examined by an experienced expert under a Carl Zeiss microscope (Carl Zeiss Microscopy GmbH, Jena, Germany). Results: All samples were found to have passed the fatigue test in the masticatory simulator without any of the listed complications. The average value of the compressive strength at which the structures in each group fracture is as follows: Group A, 5669.2; Group B, 3126.5; and Group C, 1850.6. Based on the average values, it can be concluded that the combination of materials used in Group A has the greatest resistance. Conclusion: The weak link in the prosthetic complex consisting of a crown and abutment seems to be the crown. No abutment failure was found regardless of the type. However, monolithic zirconia crowns over standard titanium abutments withstand higher mechanical forces compared with zirconia and lithium disilicate crowns over customized ones. Detailed studies in clinical settings may provide more in-depth information on this issue.

27 March 2022 in Crystals
Verified
Journal Article
Open access
PDF file
DFDimitar Filtchev
Dimitar Filtchev
Daniela StoevaDaniela Stoeva
Daniela Stoeva
BTBranka Trifkovic
Branka Trifkovic
DJDanimir Jevremović
Danimir Jevremović
GIGeorgi Iliev
Georgi Iliev
The aim of this study was to assess the mechanical behavior and the microleakage of crown abutments made of lithium disilicate (LDS), adhesively bonded to preconditioned titanium bonding base under dynamic loading considering the type of teeth incisors, premolars, and molars. Thirty-three monolithic LDS implant supra-structures, representing a copy of natural tooth morphology (central incisor, second premolar, or first molar) were fabricated and bonded to titanium bases, screw-retained on the implant, and subjected to dynamic loading of 250,000 loading cycles at 2 Hz. After mechanical cycling, specimens were immersed in 5% methylene blue solution for 24 h at 37 °C. Microleakage was evaluated under magnification. The presence or absence of the following parameters were also evaluated: abutment screw deformation, abutment deformation, crack or craze line on the ceramic structure, adhesive failure between titanium base and ceramic superstructure, failures in ceramic superstructure or titanium base, and remaining cement around titanium base and ceramic superstructure. Considering the type of teeth, there are eight defects in relation to the group of central incisors, whereas the group of first molars accounts for seven defects. The second premolar is the worst performer with eleven defects. Significant accumulation of dye was registered in all teeth groups, i.e., grade 2 (staining around hexagonal area of the connection), according to the applied scale. Failure of hybrid abutments could be related to the correct seal between the titanium base and the ceramic restorations. The type of teeth could also be related to the presence of failures.

2 October 2026 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
VUVecihe Merve Balta Uysal
Vecihe Merve Balta Uysal
AMAleksa Marković
Aleksa Marković
TMTijana Mišić
Tijana Mišić
MŠMiodrag Šćepanović
Miodrag Šćepanović
BTBranka Trifkovic
Branka Trifkovic
BJBojan Janjić
Bojan Janjić