Florian Kipfmueller

Prof. Dr. Florian Kipfmueller

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MHMarisol Herrera-Rivero
Marisol Herrera-Rivero
RZRong Zhang
Rong Zhang
SHStefanie Heilmann-Heimbach
Stefanie Heilmann-Heimbach
AMAndreas Mueller
Andreas Mueller
SBSoyhan Bagci
Soyhan Bagci
FKFlorian Kipfmueller
Florian Kipfmueller
Pulmonary hypertension (PH) contributes to high mortality in congenital diaphragmatic hernia (CDH). A better understanding of the regulatory mechanisms underlying the pathology in CDH might allow the identification of prognostic biomarkers and potential therapeutic targets. We report the results from an expression profiling of circulating microRNAs (miRNAs) in direct post-pulmonary blood flow of 18 CDH newborns. Seven miRNAs differentially expressed in children that either died or developed chronic lung disease (CLD) up to 28 days after birth, compared to those who survived without developing CLD during this period, were identified. Target gene and pathway analyses indicate that these miRNAs functions include regulation of the cell cycle, inflammation and morphogenesis, by targeting molecules responsive to growth factors, cytokines and cellular stressors. Furthermore, we identified hub molecules by constructing a protein-protein interaction network of shared targets, and ranked the relative importance of the identified miRNAs. Our results suggest that dysregulations in miRNAs let-7b-5p, -7c-5p, miR-1307-3p, -185-3p, -8084, -331-3p and -210-3p may be detrimental for the development and function of the lungs and pulmonary vasculature, compromise cardiac function and contribute to the development of CLD in CDH. Further investigation of the biomarker and therapeutic potential of these circulating miRNAs is encouraged.

5 January 2018 in Pediatric Pulmonology
Verified
Journal Article
Closed access
PDF file
FKFlorian Kipfmueller
Florian Kipfmueller
LSLukas Schroeder
Lukas Schroeder
CBChristoph Berg
Christoph Berg
KHKatrin Heindel
Katrin Heindel
PBPeter Bartmann
Peter Bartmann
AMAndreas Mueller
Andreas Mueller

22 May 2024 in Life
Verified
Journal Article
Open access
PDF file
Florian Recker, MMEFlorian Recker, MME
Florian Recker, MME
FKFlorian Kipfmueller
Florian Kipfmueller
AWAgnes Wittek
Agnes Wittek
BSBrigitte Sabine Strizek
Brigitte Sabine Strizek
LWLone Winter
Lone Winter
Point-of-care ultrasound (POCUS) integration into neonatology offers transformative potential for diagnostics and treatment, enhancing immediacy and precision of clinical decision-making in this vulnerable patient population. This systematic review aims to synthesize evidence on POCUS applications, benefits, challenges, and educational strategies in neonatology. Literature search was conducted using SPIDER scheme keywords and MeSH terms related to POCUS and neonatology. Studies focusing on POCUS applications, its impact on clinical outcomes, and educational interventions for skill acquisition were included and analyzed using standardized tools, followed by a narrative synthesis of the findings. The search yielded 68 relevant publications, encompassing original research, reviews, and guidelines. POCUS applications varied across cardiovascular, pulmonary, neurological, and abdominal assessments. Key benefits included a reduced need for invasive procedures and rapid bedside diagnosis. Challenges included steep learning curves for clinicians and the need for standardized training and guidelines. Educational strategies highlighted the effectiveness of simulation-based training in enhancing ultrasound proficiency among neonatal care providers. POCUS represents a significant advancement in neonatal medicine, offering benefits for patient care. Addressing identified challenges through comprehensive training programs and developing standardized guidelines is crucial for optimized use. Future research should focus on evaluating educational outcomes and long-term impacts of POCUS integration into neonatal care.

1 February 2023 in Radiology: Cardiothoracic Imaging
Verified
Journal Article
Closed access
TVThomas M. Vollbrecht
Thomas M. Vollbrecht
CHChristopher Hart
Christopher Hart
SZShuo ZHANG
Shuo ZHANG
CKChristoph Katemann
Christoph Katemann
AIAlexander Isaak
Alexander Isaak
JLJulian A. Luetkens
Julian A. Luetkens
To apply Doppler US (DUS)-gated fetal cardiac cine MRI in clinical routine and investigate diagnostic performance in complex congenital heart disease (CHD) compared with that of fetal echocardiography. In this prospective study (May 2021 to March 2022), women with fetuses with CHD underwent fetal echocardiography and DUS-gated fetal cardiac MRI on the same day. For MRI, balanced steady-state free precession cine images were acquired in the axial and optional sagittal and/or coronal orientations. Overall image quality was assessed on a four-point Likert scale (from 1 = nondiagnostic to 4 = good image quality). The presence of abnormalities in 20 fetal cardiovascular features was independently assessed by using both modalities. The reference standard was postnatal examination results. Differences in sensitivities and specificities were determined by using a random-effects model. The study included 23 participants (mean age, 32 years ± 5 [SD]; mean gestational age, 36 weeks ± 1). Fetal cardiac MRI was completed in all participants. The median overall image quality of DUS-gated cine images was 3 (IQR, 2.5-4). In 21 of 23 participants (91%), underlying CHD was correctly assessed by using fetal cardiac MRI. In one case, the correct diagnosis was made by using MRI only (situs inversus and congenitally corrected transposition of the great arteries). Sensitivities (91.8% [95% CI: 85.7, 95.1] vs 93.6% [95% CI: 88.8, 96.2]; P = .53) and specificities (99.9% [95% CI: 99.2, 100] vs 99.9% [95% CI: 99.5, 100]; P > .99) for the detection of abnormal cardiovascular features were comparable between MRI and echocardiography, respectively. Using DUS-gated fetal cine cardiac MRI resulted in performance comparable with that of using fetal echocardiography for diagnosing complex fetal CHD.Keywords: Pediatrics, MR-Fetal (Fetal MRI), Cardiac, Heart, Congenital, Fetal Imaging, Cardiac MRI, Prenatal, Congenital Heart DiseaseClinical trial registration no. NCT05066399 Supplemental material is available for this article. © RSNA, 2023See also the commentary by Biko and Fogel in this issue.

Verified
Journal Article
Open access
PDF file
FKFlorian Kipfmueller
Florian Kipfmueller
SASuemeyra Akkas
Suemeyra Akkas
FPFlaminia Pugnaloni
Flaminia Pugnaloni
BBBartolomeo Bo
Bartolomeo Bo
LLLotte Lemloh
Lotte Lemloh
AMAndreas Müller
Andreas Müller
Background: Assessment of pulmonary hypertension (PH) is essential in neonates with congenital diaphragmatic hernia (CDH). Echocardiography is widely established to quantify PH severity, but currently used parameters have inherent limitations. The aim of our study was to investigate the prognostic utility of the index of the pulmonary artery acceleration time to the right ventricular ejection time (PAAT:ET) in CDH neonates assessed using echocardiography. Methods: PAAT:ET values were prospectively measured in CDH neonates on admission, on day of life (DOL) 2 and DOL 5–7. Optimal cut-off values to predict mortality and need for ECMO were calculated and PAAT:ET values were compared between non-ECMO survivors, ECMO-survivors, and ECMO-non-survivors. Results: 87 CDH neonates were enrolled and 39 patients required ECMO therapy. At baseline, PAAT:ET values were significantly lower in ECMO patients compared to non-ECMO patients (p < 0.001). ECMO survivors and ECMO non-survivors had similar values at baseline (p = 0.967) and DOL 2 (p = 0.124) but significantly higher values at DOL 5–7 (p = 0.003). Optimal PAAT:ET cut-off for predicting ECMO was 0.290 at baseline and 0.310 for predicting non-survival in patients on ECMO at DOL 5–7. Conclusion: PAAT:ET is a feasible parameter for early risk assessment in CDH neonates.

29 November 2017 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
BSBrigitte Stiller
Brigitte Stiller
RHRobert Jan Houmes
Robert Jan Houmes
ARAndré Rüffer
André Rüffer
MKMatthias Kumpf
Matthias Kumpf
AMAndreas Müller
Andreas Müller
TFThilo Fleck
Thilo Fleck