BACKGROUND: Fetal cardiovascular magnetic resonance is an emerging tool for prenatal congenital heart disease assessment, but long acquisition times and fetal movements limit its clinical use. This study evaluates the clinical utility of deep learning super-resolution reconstructions for rapidly acquired, low-resolution fetal cardiovascular magnetic resonance. METHODS: This prospective study included participants with fetal congenital heart disease undergoing fetal cardiovascular magnetic resonance in the third trimester of pregnancy, with axial cine images acquired at normal resolution and low resolution. Low-resolution cine data was subsequently reconstructed using a deep learning super-resolution framework (cine DL ). Acquisition times, apparent signal-to-noise ratio, contrast-to-noise ratio, and edge rise distance were assessed. Volumetry and functional analysis were performed. Qualitative image scores were rated on a 5-point Likert scale. Cardiovascular structures and pathological findings visible in cine DL images only were assessed. Statistical analysis included the Student paired t test and the Wilcoxon test. RESULTS: A total of 42 participants were included (median gestational age, 35.9 weeks [interquartile range (IQR), 35.1–36.4]). Cine DL acquisition was faster than cine images acquired at normal resolution (134±9.6 s versus 252±8.8 s; P <0.001). Quantitative image quality metrics and image quality scores for cine DL were higher or comparable with those of cine images acquired at normal-resolution (eg, fetal motion, 4.0 [IQR, 4.0–5.0] versus 4.0 [IQR, 3.0–4.0]; P <0.001). Nonpatient-related artifacts (eg, backfolding) were more pronounced in cine DL compared with cine images acquired at normal-resolution images (4.0 [IQR, 4.0–5.0] versus 5.0 [IQR, 3.0–4.0]; P <0.001). Volumetry and functional results were comparable. Cine DL revealed additional structures in 10 of 42 fetuses (24%) and additional pathologies in 5 of 42 fetuses (12%), including partial anomalous pulmonary venous connection. CONCLUSIONS: Deep learning super-resolution reconstructions of low-resolution acquisitions shorten acquisition times and achieve diagnostic quality comparable with standard images, while being less sensitive to fetal bulk movements, leading to additional diagnostic findings. Therefore, deep learning super-resolution may improve the clinical utility of fetal cardiovascular magnetic resonance for accurate prenatal assessment of congenital heart disease.
Background: In pediatric magnetic resonance imaging (MRI), reducing the rate of non-diagnostic scans due to artifacts and shortening acquisition time are crucial not only for economic reasons but also to minimize sedation or general anesthesia. Objective: Enabling faster and motion-robust MRI of the brain in infants and children using a novel, enhanced compressed sensing (CS) algorithm in combination with a turbo-spin-echo T2-weighted sequence utilizing the PROPELLER-technique (periodically rotated overlapping parallellines with enhanced reconstruction; T2PROPELLER CS). Materials and methods: This prospective study included 31 patients (8.0 ± 4.7 years, 15 males) undergoing a clinically indicated MRI examination of the brain on a 3-T scanner. The T2PROPELLER CS sequence was compared to a conventional, CS-accelerated Cartesian turbo-spin-echo T2-weighted sequence (T2Cartesian CS). Apparent contrast-to-noise ratio (aCNR) and signal-to-noise ratio (aSNR) were calculated. Three blinded radiologists independently rated both sequences twice qualitatively on a 5-point Likert-scale from 1–5 (non-diagnostic–excellent) for artifacts, image sharpness, basal ganglia delineation, lesion conspicuity, and overall image quality. Statistical analysis was performed using the Wilcoxon signed-rank test and paired sample t test. Intra- and interrater reliability of qualitative image assessment was evaluated by computing Krippendorff’s $$\alpha$$ reliability estimates. Results: The average acquisition time of the T2PROPELLER CS (189 ± 27 s) was 31% shorter than that of the T2Cartesian CS sequence (273 ± 21 s; P < 0.001). aCNR (7.7 ± 4.6 vs. 6.2 ± 2.8; P = 0.004) and aSNR (24.8 ± 9.7 vs. 18.8 ± 5.5; P < 0.001) were higher for the T2Cartesian CS compared to the T2PROPELLER CS sequence. The T2PROPELLER CS sequence significantly reduced (motion-)artifacts (P < 0.001) and increased image sharpness (P < 0.001), basal ganglia delineation (P<0.001), lesion conspicuity (raters 1 and 2, P < 0.001; rater 3, P = 0.004), and overall image quality (P < 0.001). Metal artifacts were prominent in both sequences, though slightly more pronounced in the T2PROPELLER CS sequence. Conclusion: The T2PROPELLER CS sequence enables faster and motion-robust imaging of the brain in infants and children, reducing the rate of non-diagnostic scans and potentially allowing sedation or general anesthesia to be minimized in the future. Graphical
Objectives: The purpose of this study was to assess whether a 3-min 2D knee protocol can meet the needs for clinical application if using a SuperResolution reconstruction approach. Methods: In this prospective study, a total of 20 volunteers underwent imaging of the knee using a 3T MRI scanner (Philips Ingenia Elition X 3.0T, Philips). The imaging protocol, consisting of a fat-saturated 2D proton density sequence in coronal, sagittal, and transverse orientations, as well as a sagittal T1-weighted sequence, was acquired with standard and ultra-low resolution. The standard sequences were reconstructed using an AI-assisted Compressed SENSE method (SmartSpeed). The ultra-low-resolution sequences have been reconstructed using a vendor-provided prototype. Four experienced readers (two radiologists and two orthopedic surgeons) evaluated the sequences for image quality, anatomical structures, and incidental pathologies. The consensus evaluation of two different experienced radiologists specialized in musculoskeletal imaging served as the gold standard. Results: The acquisition time for the entire protocol was 11:01 min for standard resolution and 03:36 min for ultra-low resolution. In the overall assessment, CS-SuperRes-reconstructed sequences showed slightly improved accuracy and increased specificity compared to the standard CS-AI method (0.87 vs. 0.86 and 0.9 vs. 0.87, respectively), while the standard method exhibited a higher sensitivity (0.73 vs. 0.57). Overall, 24 out of 40 pathologies were detected in the ultra-low-resolution images compared to 26 in the standard images. Conclusions: The CS-SuperRes method enables a 2D knee protocol to be completed in 3 min, with improved accuracy compared to the clinical standard.
Objectives: To evaluate proton density fat fraction (PDFF) and T2* measurements of the liver with combined parallel imaging (sensitivity encoding, SENSE) and compressed sensing (CS) accelerated chemical shift encoding-based water-fat separation. Methods: Six-echo Dixon imaging was performed in the liver of 89 subjects. The first acquisition variant used acceleration based on SENSE with a total acceleration factor equal to 2.64 (acquisition labeled as SENSE). The second acquisition variant used acceleration based on a combination of CS with SENSE with a total acceleration factor equal to 4 (acquisition labeled as CS+SENSE). Acquisition times were compared between acquisitions and proton density fat fraction (PDFF) and T2*-values were measured and compared separately for each liver segment. Results: Total scan duration was 14.5 sec for the SENSE accelerated image acquisition and 9.3 sec for the CS+SENSE accelerated image acquisition. PDFF and T2* values did not differ significantly between the two acquisitions ( paired Mann-Whitney and paired t-test P>0.05 in all cases). CS+SENSE accelerated acquisition showed reduced motion artifacts (1.1%) compared to SENSE acquisition (12.3%). Conclusion: CS+SENSE accelerates liver PDFF and T2*mapping while retaining the same quantitative values as an acquisition using only SENSE and reduces motion artifacts. Strengths of this study: Compressed sensing allows accelerated imaging with reduction of motion artifacts without alteration of quantitative measurements Robust results in fat and iron quantification in a heterogeneous patient cohort Limitations of this study: No histopathological validation of the MR findings was performed The study was not performed at different field strengths