Buildings play a central role in energy transition, as they were responsible for 67.8% of the total consumption of electricity in France in 2017. Because of that, detecting anomalies (outliers) is crucial in order to identify both potential opportunities to reduce energy consumption and malfunctioning of the metering system. This work aims to compare the performance of several outlier detection methods, such as classical statistical methods (as boxplots) applied to the actual measurements and to the difference between the measurements and their predictions, in the task of detecting outliers in the power consumption data of a tertiary building located in France. The results show that the combination of a regression method, such as random forest, and the adjusted boxplot outlier detection method have promising potential in detecting this type of data quality problem in electricity consumption.
1 March 2017 in Journal of Microwaves, Optoelectronics and Electromagnetic Applications
The single phase equivalent circuit is largely used to model the three-phase induction motors in steady-state operation and under sinusoidal balanced voltages. Depending on the desired application, the circuit may or may not represent core losses, a double cage or even the variation of parameters due to skin effect and saturation. However, the determination of the circuit parameters through standard methods, such as those described in IEEE Standard 112, may not be possible in many situations given the lack of the necessary resources. This paper presents initially a survey on the determination of circuit parameters from alternative methods, i.e., non-standard tests. Special focus is given to methods which employ only data usually provided by manufacturers on catalogs and nameplates. Six analytical methodologies used in the context of efficiency estimation at steady-state operation are assessed, compared and then combined in order to improve results. The assessment is based on the closeness of the resulting parameter values to reference values and on the inexistence of absurd results, such as negative electrical resistances. The combination of methods has improved the accuracy of calculations for the studied motors.
This paper presents a new non invasive technique for fuel cell diagnosis. The method relies on the measurements of the magnetic field signature generated by a working fuel cell. Knowing the relationship between currents and magnetic field, it is possible to estimate the current density by solving an inverse problem. This problem being ill-posed, original current and sensors basis are proposed to improve the reconstruction process. The experimental set-up remains simple, based on few fixed sensors and shows a good efficiency.
The Facet finite-element method (FFEM) requires a source field solution that is commonly obtained by the Biot-Savart (BS) equation that can be time-consuming. The subproblem modeling is applied to the FFEM in order to minimize the computational effort and time necessary to obtain the solution. The volume sources, which allow solving the BS equation only along the active regions, are presented, as well as the BS boundary condition correction.
In this paper a magnetic vector hysteresis model based on Play hysterons is presented. This model allows the evaluation of the magnetic induction vector from an imposed magnetic field vector. The proposed methodology is simple to implement and needs only a small set of experimental data. Some aspects of the model are discussed and an experimental validation is performed
Following the recent European directives highlighting the need to increase energy efficiency in the European Union, this work aims to show the possibility of using Non-Intrusive Load Monitoring (NILM) techniques to improve energy audits by estimating the compressed air leakage from a dataset of a tertiary building. The first step towards the reduction of energy consumption is performing an energy audit, in which a detailed analysis of the energy performance is executed. This analysis usually uses on-site measured data by the auditors. However, the time available for these measurements is limited and may not include some modes of operation. One example of that is the quantification of compressed air leaks. This task can be performed by estimating the flow rate during a no compressed air consumption period. However, these periods may not coincide with the auditors’ original schedule. This problem could be addressed by using historical data. Nevertheless, historical data from energy management systems usually are only available for global consumption, and rarely for individual appliances. In this context, a NILM approach would be helpful to enhance energy audits carrying analysis of modes of operation not included in the on-site measurements. In this paper, the leaks are firstly quantified using measurements mostly for benchmarking purposes. The results suggested 62% of leaks in the study case. In a second step, the Factorial Hidden Markov Model (FHMM) was applied to the data. Five typical working days, simulating the context of an energy audit, were used as training data, while one week during vacation time, with no compressed air consumption, was used to quantify the leaks. The results show that it was possible, in the context of an energy audit, to estimate the compressed air leakage using NILM techniques in this dataset with less than a 1% difference when compared to the estimation made with actual measurement. Finally, savings estimations considering the elimination of the leaks were performed, varying between 10% and 100% of the leakage repair. Considering the ideal scenario of complete leaks elimination, the savings would represent around 44% in the compressed air system and 4.75% of the current annual global consumption.